PubMed Health⌕ Search

Biomedical subjects

Huiru Zheng

Publications and source records attributed to Huiru Zheng.

5 recordsLinked to original sources

Machine learning approaches to supporting the identification of photoreceptor-enriched genes based on expression data.

BACKGROUND: Retinal photoreceptors are highly specialised cells, which detect light and are central to mammalian vision. Many retinal diseases occur as a result of inherited dysfunction of the rod and cone photoreceptor cells. Development and maintenance of photoreceptors requires appropriate regulation of the many genes specifically or highly expressed in these cells. Over the last decades, different experimental approaches have been developed to identify photoreceptor enriched genes. Recent progress in RNA analysis technology has generated large amounts of gene expression data relevant to retinal development. This paper assesses a machine learning methodology for supporting the identification of photoreceptor enriched genes based on expression data. RESULTS: Based on the analysis of publicly-available gene expression data from the developing mouse retina generated by serial analysis of gene expression (SAGE), this paper presents a predictive methodology comprising several in silico models for detecting key complex features and relationships encoded in the data, which may be useful to distinguish genes in terms of their functional roles. In order to understand temporal patterns of photoreceptor gene expression during retinal development, a two-way cluster analysis was firstly performed. By clustering SAGE libraries, a hierarchical tree reflecting relationships between developmental stages was obtained. By clustering SAGE tags, a more comprehensive expression profile for photoreceptor cells was revealed. To demonstrate the usefulness of machine learning-based models in predicting functional associations from the SAGE data, three supervised classification models were compared. The results indicated that a relatively simple instance-based model (KStar model) performed significantly better than relatively more complex algorithms, e.g. neural networks. To deal with the problem of functional class imbalance occurring in the dataset, two data re-sampling techniques were studied. A random over-sampling method supported the implementation of the most powerful prediction models. The KStar model was also able to achieve higher predictive sensitivities and specificities using random over-sampling techniques. CONCLUSION: The approaches assessed in this paper represent an efficient and relatively inexpensive in silico methodology for supporting large-scale analysis of photoreceptor gene expression by SAGE. They may be applied as complementary methodologies to support functional predictions before implementing more comprehensive, experimental prediction and validation methods. They may also be combined with other large-scale, data-driven methods to facilitate the inference of transcriptional regulatory networks in the developing retina. Furthermore, the methodology assessed may be applied to other data domains.

Animals↗

A computational approach for peptidomic analysis in taxonomic study of amphibian species.

Peptides in the skin secretion of frogs have been studied for some time now because they frequently possess important biological activity such as antibiotic, antimicrobial, or anticancer properties. In this paper, we present a computational approach for measuring the degree of similarity between the entire peptide complement of the skin secretion of specimens from the same or different species. The first step in the analysis is the generation of a mass spectral profile from an experimental high-performance liquid chromatography/electrosparay ionization analysis of the sample. An "overlap" between the mass spectral profiles of different specimens is then proposed as a measure of their similarity. Analysis of specimens from three species of the genus Litoria, viz., L. Aurea, L. Caerulea, and L. Infrafrenata, and Rana Capito of genus Rana shows that the degree of similarity is highest between specimens from the same species, lower for specimens from different species of the same genus, and lowest between specimens from different genera. This indicates that comparison of skin peptide profiles (i.e., mass spectral profiles of skin secretion) is potentially a useful aid in the taxonomic study of amphibian species.

Algorithms↗

Cross-sectional area reduction of the aortic ostium by suprarenal stent wires: in vitro phantom study by CT virtual angioscopy.

The study aims to investigate the reduction of cross-sectional area of the aortic ostium by the presence of aortic stent wires observed using CT virtual angioscopy in an aorta phantom. A human aorta phantom was built with a commercial stent graft placed in situ to simulate a repaired aortic aneurysm. Virtual angioscopic images of the aortic ostium and stent wires were generated in the locations of renal arteries, superior mesenteric artery and corresponding cross-sectional area reduction caused by stent wires was measured by virtual angioscopy in various scanning parameters. Our study showed that cross-sectional area reduction of the aortic ostium was determined by the diameter of renal ostium and stent wires, as well as the number of stent wires crossing the aortic ostium.

Angioscopy↗

Increasing face validity of a vascular interventional training system.

BACKGROUND: Many aspects of medical training take place on real patients in a live environment thus incurring risk. Apart from the obvious risks to patients there is the issue of X-ray exposure to both staff and trainees. Image quality used during interventional procedures is low to ensure minimum X-ray radiation dose. A virtual interventional system may be used to simulate the interventional cardiology training environment therefore reducing overall risk. The purpose of this project was to determine the appropriate image quality settings on a virtual training system to accurately simulate interventional cardiology and increase the face validity of the overall system. METHODS: Real image data was obtained from patients undergoing diagnostic interventional cardiology examinations in the Royal Victoria Hospital, Belfast. The images were obtained during catheter placement and contrast enhancement around the region of the heart. The diagnostic views were left anterior oblique, right anterior oblique, left lateral, caudal and the spider view. These five views were simulated on a virtual interventional training system (VIST, Mentice Medical Simulation AB, Sweden) by adjusting x-ray tube and table position at 20 different image quality settings. Signal to noise ratio and image contrast were measured for each of these views using soft tissue and vertebra. The results from the real image data and the VIST image data were compared. Calibration curves were compiled to determine the appropriate VIST image quality setting for each procedure. RESULTS: Average SNR ranged from 2.94 to 74.0 and IC ranged from 0.009 to 0.61 on the real image data. This indicates the very wide range of image quality encountered in interventional cardiology. Calibration curves for each view with the corresponding range of real patient image quality were produced. These calibration curves enabled the appropriate VIST image quality setting to be determined and therefore simulate the real examination image quality as closely as possible. CONCLUSIONS: The VIST system has been calibrated in terms of image quality for interventional cardiology examinations. This has increased the face validity of the system.

Cardiology↗

Heuristic charge assignment for deconvolution of electrospray ionization mass spectra.

We propose a new algorithm for deconvolution of electrospray ionization mass spectra based on direct assignment of charge to the measured signal at each mass-to-charge ratio (m/z). We investigate two heuristics for charge assignment: the entropy-based heuristic is adapted from a deconvolution algorithm by Reinhold and Reinhold;10 the multiplicative-correlation heuristic is adapted from the multiplicative-correlation deconvolution algorithm of Hagen and Monnig.6 The entropy-based heuristic is insensitive to overestimates of z(max), the maximum ion charge. We test the deconvolution algorithm on two single-component samples: the measured spectrum of human beta-endorphin has two prominent and one very weak line whereas myoglobin has a well-developed quasi-gaussian envelope of 17 peaks. In both cases, the deconvolution algorithm gives a clean deconvoluted spectrum with one dominant peak and very few artefacts. The relative heights of the peaks due to the parent molecules in the deconvoluted spectrum of a mixture of two peptides, which are expected to ionize with equal efficiency, give an accurate measure of their relative concentration in the sample.

Algorithms↗