PubMed Health⌕ Search

Biomedical subjects

Huw Griffiths

Publications and source records attributed to Huw Griffiths.

4 recordsLinked to original sources

Feasibility and cost of treatment with drug eluting stents of surgical candidates with multi-vessel coronary disease.

OBJECTIVE: To determine the feasibility and cost of treatment with drug eluting stents in patients with multi-vessel coronary disease referred currently for surgical revascularisation. METHODS: Two experienced interventional cardiologists reviewed retrospectively the clinical records and pre-operative coronary angiograms of 209 patients who underwent their first coronary bypass operation for multi-vessel disease without other adjunctive surgical procedures at the Royal Brompton Hospital in 2002. They were classified according to the technical feasibility and completeness of percutaneous revascularisation. A cost decision-analysis model with a cost of drug eluting stents of euro 2,100 and simulated 1-year costs was constructed. RESULTS: Mean age was 64.6+/-8.9 years with 54 diabetics (25.8%). Each patient received at least 1 arterial graft and a mean of 3.0+/-0.8 distal anastomoses. Mean post-operative stay was 8.9+/-7.2 days and total cost euro 19,821+/-1,964. Percutaneous revascularisation was judged to be feasible in 158 (76%) cases. The contraindications were at least 1 unfavourable total occlusion subtending viable myocardium in 48 patients (23%) and extreme tortuosity or calcification in 4 patients (2%). Percutaneous revascularisation of grafted major epicardial vessels was anticipated to be complete in 138 (66%) patients and partial but acceptable in 19 (9.1%) patients. Stenting of the left main, of a 'favourable' total occlusion, of bifurcations or in an ostial location would have been required in 32 (20.4%), 60 (38.2%), 77 (49.0%) and 74 (47.1%), respectively, of cases treated. 3.6+/-1.4 drug eluting stents of total length 72.6+/-37.3 mm were required to treat 3.3+/-1.2 lesions per patient at an estimated cost of euro 17,266+/-2,850. When one year repeat revascularisation was modelled at a rate of 15% in the stent group there was no significant cost saving from stenting. CONCLUSIONS: Although percutaneous revascularisation is feasible in 76% of patients currently undergoing coronary artery bypass grafting for multi-vessel disease, such an approach will involve frequent treatment of complex lesions for which no long term results are available and is unlikely to provide appreciable economic savings.

Aged↗

Drug-eluting bioabsorbable magnesium stent.

Current stent technology is based on the use of permanent implants that remain life long in the vessel wall, far beyond the time required for the prosthesis to accomplish its main goals of sealing dissection and preventing wall recoil. With the possibility to implant long vessel segments using antiproliferative drugs to prevent restenosis, the practice of transforming the coronary vessels into stiff tubes with a full metal jacket covering all side branches and being unable to adjust to the long-term wall changes, including wall remodeling with lumen ectasia becomes a serious concern. In this article, we describe the first biodegradable stent based on a magnesium alloy that allows controlled corrosion with release to the vessel wall and the blood stream of a natural body component such as magnesium with beneficial antithrombotic, antiarrhythmic, and antiproliferative properties. We also discuss the animal experiments and the initial clinical applications in 20 patients with implants below the knee, with final results soon to be released, and the plans for the first coronary study. The results of these last two studies will indicate whether the absence of a permanent implant and the antiproliferative properties shown in animals are sufficient to prevent the restenotic process in humans or whether the prosthesis must be modified by adding the biodegradable coating with conventional antiproliferative drugs.

Absorbable Implants↗

Xdigitise: visualization of hybridization experiments.

UNLABELLED: Xdigitise is a software system for visualization of hybridization experiments giving the user facilities to analyze the corresponding images manually or automatically. Images of the high-density DNA arrays are displayed as well as the results of an external image analysis bundled with Xdigitise, e.g. the spot locations are marked and the duplicate correlations are shown by a color scale. AVAILABILITY: Xdigitise can be downloaded from http://www.molgen.mpg.de/~xdigitise.

Algorithms↗