PubMed Health⌕ Search

Biomedical subjects

Hyeon-Bong Pyo

Publications and source records attributed to Hyeon-Bong Pyo.

5 recordsLinked to original sources

Study of SU-8 to make a Ni master-mold: Adhesion, sidewall profile, and removal.

For disposable microfluidic devices, easy and inexpensive fabrication is essential. Consequently, replication of microfluidic devices, using injection molding or hot embossing, from a master-mold is widely used. However, the conventional master-mold fabrication technique is unsatisfactory in terms of time and costs. In this regard, direct Ni growth (electroplating) from a back plate is promising when the photoresist is well-defined. Here, we demonstrate the use of SU-8 as a photoresist to define the Ni-growth region. We accomplish this application by focusing on the adhesion, the sidewall profile, and the removal of SU-8: the adhesion is enhanced by controlling the exposure dose, the soft-baking time, and by choosing the adhesion-promoting layer; the sidewall profile is regulated by selecting the intensity of each exposed wavelength, showing an aspect ratio of up to 20.9; and, easy removal is achieved by choosing a proper photoresist-stripper. Using the master-mold fabricated by this method, we test the mechanical stability of the features according to the aspect ratio and length; in the hot embossing process, the features are stable in the aspect ratio of up to 5.8 at a length of 200 microm. In addition, the plastic devices fabricated from this method are applied to the passive stop valves, showing a capillary pressure (-0.2 to -7.2 kPa).

Adhesiveness↗

Wafer-scale fabrication of polymer-based microdevices via injection molding and photolithographic micropatterning protocols.

Because of their broad applications in biomedical analysis, integrated, polymer-based microdevices incorporating micropatterned metallic and insulating layers are significant in contemporary research. In this study, micropatterns for temperature sensing and microelectrode sets for electroanalysis have been implemented on an injection-molded thin polymer membrane by employing conventional semiconductor processing techniques (i.e., standard photolithographic methods). Cyclic olefin copolymer (COC) is chosen as the polymer substrate because of its high chemical and thermal stability. A COC 5-in. wafer (1-mm thickness) is manufactured using an injection molding method, in which polymer membranes (approximately 130 microm thick and 3 mm x 6 mm in area) are implemented simultaneously in order to reduce local thermal mass around micropatterned heaters and temperature sensors. The highly polished surface (approximately 4 nm within 40 microm x 40 microm area) of the fabricated COC wafer as well as its good resistance to typical process chemicals makes it possible to use the standard photolithographic and etching protocols on the COC wafer. Gold micropatterns with a minimum 5-microm line width are fabricated for making microheaters, temperature sensors, and microelectrodes. An insulating layer of aluminum oxide (Al2O3) is prepared at a COC-endurable low temperature (approximately 120 degrees C) by using atomic layer deposition and micropatterning for the electrode contacts. The fabricated microdevice for heating and temperature sensing shows improved performance of thermal isolation, and microelectrodes display good electrochemical performances for electrochemical sensors. Thus, this novel 5-in. wafer-level microfabrication method is a simple and cost-effective protocol to prepare polymer substrate and demonstrates good potential for application to highly integrated and miniaturized biomedical devices.

Electrochemistry↗

Holographic polarization-selective module based on a small dove prism coupler for magneto-optical pickup heads.

A new structure for polarization-selective elements, consisting of two holographic gratings and a Dove prism coupler, is proposed. The absence of a multistage waveguide and the benefits of compact size and lightweight volume are the outstanding features of the new structure. Based on the coupled-wave theory, the analysis and design of the structure are discussed in detail to calculate the required index modulation. Several parameters, such as the recording intensity, the exposure time, and the recording angles for the fabrication of the proposed element, are determined. Under these conditions, the element is fabricated in Dupont photopolymer HRF-150-38 material and with an operating wavelength of 532 nm. A simplified pickup head is constructed to evaluate the performance of the fabricated element.

Journal Article↗

Multichannel surface plasmon resonance imaging and analysis of micropatterned self-assembled monolayers and protein affinity interactions.

Multichannel images of 11-mercaptoundecanoic acid and 11-mercapto-1-undecanol self-assembled monolayers together with a biospecific interferon-gamma (IFN-gamma)/anti-IFN-gamma antibody immunoaffinity interaction were observed by the two-dimensional surface plasmon resonance (2D-SPR) imaging system. With the fabricated 2D-SPR imaging system, adopting a white light source in combination with a narrow band-pass filter, sharp images were resolved, minimizing the diffraction patterns on the resulting images. Micropatterning of self-assembled monolayers was acheived by exploiting the UV photolysis of thiol bonding, instead of conventional photolithography. The line profile calibration of the image contrast with ellipsometric analysis enabled us to discriminate the change in monolayer thickness within a sub-nanometer scale. For the protein interactions on the surface, the biospecific affinity recognition reaction of IFN-gamma antigen with surface-immobilized antibody was analyzed. Through the signal amplification strategy based on the enzyme-catalyzed precipitation reaction in a sandwich-type immunoassay, biospecific antigen binding was found detectable down to a concentration of 1 ng/mL.

Proteins↗

A polymer-based microfluidic device for immunosensing biochips.

This paper describes the design, fabrication, and test of a PDMS/PMMA-laminated microfluidic device for an immunosensing biochip. A poly(dimethyl siloxane)(PDMS) top substrate molded by polymer casting and a poly(methyl methacrylate)(PMMA) bottom substrate fabricated by hot embossing are bonded with pressure and hermetically sealed. Two inlet ports and an air vent are opened through the PDMS top substrate, while gold electrodes for electrochemical biosensing are patterned onto the PMMA bottom substrate. The analyte sample is loaded from the sample inlet port to the detection chamber by capillary force, without any external intervening forces. For this and to control the time duration of sample fluid in each compartment of the device, including the inlet port, diffusion barrier, reaction chamber, flow-delay neck, and detection chamber, the fluid conduit has been designed with various geometries of channel width, depth, and shape. Especially, the fluid path has been designed so that the sample flow naturally stops after filling the detection chamber to allow sufficient time for biochemical reaction and subsequent washing steps. As model immunosensing tests for the microfluidic device, functionalizations of ferritin and biotin to the sensing surfaces on gold electrodes and their biospecific interactions with antiferritin antiserum and streptavidin have been investigated. An electrochemical detection method for immunosensing by biocatalyzed precipitation has been developed and applied for signal registration. With the biochip, the whole immunosensing processes could be completed within 30 min.

Antibodies↗