Enzyme-amplified amperometric detection of 3000 copies of DNA in a 10-microL droplet at 0.5 fM concentration.

We reported earlier the detection of a 38-base DNA strand at 20 pM concentration by an enzyme-amplified sandwich-type amperometric assay. The assay utilized a carbon electrode on which a redox polymer, comprising a DNA capture sequence, was electrodeposited. When present in the tested solution, part of the probed sequence hybridized with the capture probe. Hybridization of its remaining part with a horseradish peroxidase (HRP)-labeled sequence resulted in the flow of an H2O2 electroreduction current, the redox polymer wired HRP forming an electrocatalyst. Here we report a > 10(4)-fold improvement in the detection limit of the assay. DNA was detected at 0.5 fM concentration when the earlier used 3.6-mm-diameter carbon electrode was replaced by a 10-microm-diameter microelectrode. The radial diffusion of electrons through the film on the microelectrode allowed the electrodeposition of a thicker film of the redox polymer, an increase in the loading of the capture sequence, and increased the collection efficiency of the electron vacancies originating in the electroreduced H2O2. When the volume probed by the microelectrode was 10 microL, as few as 3000 copies of DNA were detected.

DNA↗

Simple enzyme-amplified amperometric detection of a 38-base oligonucleotide at 20 pmol L(-1) concentration in a 30- microL droplet.

A 38-base DNA sequence has been detected at 20 pmol L(-1) concentration in 15-35- microL droplets by means of an electrochemical enzyme-amplified sandwich-type assay on a mass-manufacturable screen-printed carbon electrode. Formation of the sandwich brought the horseradish peroxidase-label of the detection sequence into electrical contact with a pre-electrodeposited redox polymer, making the sandwich an electrocatalyst for the reduction of hydrogen peroxide to water at +0.2 V (Ag/AgCl). Sensitivity twenty times better than that of a related system resulted from: 1. fivefold reduction of the noise by substituting the formerly used poly( N-vinyl imidazole)-co-acrylamide comprising redox co-polymer with poly(4-vinyl pyridine)-co-acrylamide comprising redox polymer, enabling use of the electrodes at a more oxidizing potential at which noise (the rate of non-enzyme catalyzed electroreduction currents of dissolved oxygen and hydrogen peroxide) was lower; 2. doubling of the catalytic electroreduction current upon electrodeposition of a second layer of the redox polymer on the capture sequence-containing film; and 3. doubling of the current by increasing the coverage by the capture sequence.

Base Sequence↗

An oxygen cathode operating in a physiological solution.

We report the electroreduction of O(2) to water under physiological conditions (pH 7.4, 0.15 M NaCl, 37.5 degrees C) at a current density of 5 mA cm(-2) and at a potential only 0.18 V reducing versus that of the reversible O(2)/H(2)O electrode at pH 7.4. The immobilized electrocatalyst enabling the reduction is the electrostatic adduct of bilirubin oxidase from Myrothecium verrucaria, a polyanion at pH >4.1, and the polycationic redox copolymer of polyacrylamide and poly (N-vinylimidazole) complexed with [Os (4,4'-dichloro-2,2'-bipyridine)(2)Cl](+/2+), cross-linked on carbon cloth. The current density of the rotating electrodes was O(2) transport limited up to 8.8 mA cm(-2); their kinetic limit was reached at 9.1 mA cm(-2). The operational life of the electrodes depended on their angular velocity, which defined not only the current density but also the mechanical shear stress stripping the electrocatalyst. When the electrodes were rotated at 300 rpm and were poised at -256 mV versus the potential of the reversible O(2)/H(2)O electrode, their 2.4 mA cm(-2) initial current density decreased to 1.3 mA cm(-2) after 6 days of continuous operation at 37.5 degrees C.

Animals↗