Transport and storage of serotonin by thrombin-treated platelets.

Repeated thrombin treatment of washed platelets prepared from rabbits can decrease the serotonin content of the platelets by about 80%. When these platelets are deaggregated they reaccumulate serotonin but their storage capacity for serotonin is reduced by about 60%. If thrombin-pretreated platelets are allowed to equilibrate with a high concentration of serotonin (123 mu M), they release a smaller percentage of their total serotonin upon further thrombin treatment, in comparison with the percentage of serotonin released from control platelets equilibrated with the same concentration of serotonin calculations indicate that in thrombin-treated platelets reequilibrated with serotonin, two-thirds of the serotonin is in the granule compartment and one-third is in the extragranular compartment, presumably the cytoplasm. Analysis of the exchange of serotonin between the suspending fluid and the platelets showed that thrombin treatment does not alter the transport rate of serotonin across the platelet membrane and does not cause increased diffusion of serotonin from the platelets into the suspending fluid. The primary reason for the reduced serotonin accumulation by the thrombin-treated platelets appears to be loss of amine storage granules or of the storage capacity within the granules.

Animals↗

The use and analysis of multiple responses in multicompartment cellular systems.

Within multicompartment cellular systems in the steady state the distrubution of tracer as a function of time is described by sums of exponentials. A design for data collection and analysis is set forward to deal with the problems of lumping and ill-conditioning inherent in such a mathematical description. This design requires the provision of multiple responses and can be analyzed by a Bayesian multivariate technique. Although only one response may be capable of completely characterizing the system, there is much to be gained from additional responses in terms of precision in parameter estimation. A time series is used to account for autocorrelated error in the responses. The design is compared to other least squares approaches and is demonstrated in an investigation of the transport and storage of serotonin in blood platelets. The kinetic parameters describing serotinin movement are estimated and their joint confidnece regions plotted.

Blood Platelets↗