Publications and source records attributed to I Angert.

2 recordsLinked to original sources

New high-DQE imaging plate scanner using the reflected readout laser signal for noise corrections.

Imaging Plates (IPs) are in principle ideal electron detectors combining a large active layer area with a high sensitivity, linear dynamic range detection over 5 orders of magnitude. A moderate resolution and a decreasing detection quantum efficiency (DQE) for higher electron doses limit their use so far. The decrease of the DQE results from linear noise contributed by readout laser instabilities and inhomogeneities of the IP active layer. Here we present data on a new IP drum scanner prototype. This scanner combines twin channel amplification electronics with a new type of readout laser which allows a smaller readout focus and increased stability. The current nominal pixel size is 25 microm, and the measured modulation transfer function (MTF) indicates that further reduction of the scanning step size down to pixel sizes in the range of 12-15 microm should be possible. A unique feature of the new scanner is the simultaneous recording of the reflected readout laser light. The reflected light signal can be used for a posteriori alignment of repeated scans of one individual IP and for a correction of one part of the high spatial frequency noise contribution (reflected light correction). The posteriori alignment now allows an easy conventional gain normalization of the luminescence signal without using special markers on the IP. Both corrections lead to an increase of the DQE for high electron doses.

Biophysical Phenomena↗

Zero-loss image formation and modified contrast transfer theory in EFTEM.

For a weak phase/weak amplitude object the information transfer in the imaging process of TEM is described by the common formalism of the contrast transfer function (CTF). So far the effects of inelastic scattering were not accounted for in this formalism. In conventional imaging they were simply neglected. In energy filtering TEM (EFTEM), where removal of inelastic electrons leads to higher specimen contrast, they were modelled by a global increase of the elastic amplitude contrast. Thus, the description of inelastic and elastic scattering was mixed. Here a new ansatz is proposed which treats elastic and inelastic contrast transfer separately by adding an inelastic contribution to the scattering potentials. In EFTEM this has the effect of adding a filter contrast which depends on the characteristics of the inelastic scattering. For samples with dominant plasmon loss the additional filter contrast is restricted to low resolution. Because of its strong dependence on the nature of the inelastic scattering process, the filter contrast cannot in general be unified with the conventional elastic amplitude contrast. The modified CTF theory for EFTEM was tested experimentally on a variety of samples. Images of amorphous layers of copper, aluminium, and carbon films, as well as zero-loss images of proteins embedded in amorphous ice were evaluated. The values of the parameters of the additional filter contrast were determined for carbon film and proteins embedded in vitrified ice. Comparison of different CTF models used to reconstruct 3D volumes from zero-loss images confirmed that best agreement with the atomic model is attained with the new, modified CTF theory.

Actins↗