PubMed Health⌕ Search

Biomedical subjects

I Aubineau-Lanièce

Publications and source records attributed to I Aubineau-Lanièce.

8 recordsLinked to original sources

Comparison of calculated spectra for the interaction of photons in a liquid scintillator. Example of 54Mn 835 keV emission.

The CIEMAT/NIST and TDCR methods in liquid scintillation counting, initially developed for the activity standardization of pure-beta radionuclides, have been extended to the standardization of electron capture and beta-gamma radionuclides. Both methods require the calculation of the energy spectrum absorbed by the liquid scintillator. For radionuclides emitting X-rays or gamma-rays, when the energy is greater than a few tens of keV the Compton interaction is important and the absorption is not total. In this case, the spectrum absorbed by the scintillator must be calculated using analytical or stochastic models. An illustration of this problem is the standardization of 54Mn, which is a radionuclide decaying by electron capture. The gamma transition, very weakly converted, leads to the emission of an 835 keV photon. The calculation of the detection efficiency of this radionuclide requires the calculation of the energy spectrum transferred to the scintillator after the absorption of the gamma ray and the associated probability of absorption. The validity of the method is thus dependent on the correct calculation of the energy transferred to the scintillator. In order to compare the calculation results obtained using various calculation tools, and to provide the metrology community with some information on the choice of these tools, the LS working group of the ICRM organised a comparison of the calculated absorbed spectra for the 835 keV photon of 54Mn. The result is the spectrum of the energy absorbed by the scintillator per emission of an 835 keV gamma ray. This exercise was proposed for a standard 20 ml LS glass vial and for LS cocktail volumes of 10 and 15 ml. The calculation was done for two different cocktails: toluene and a widely used commercial cocktail, Ultima Gold. The paper describes the results obtained by nine participants using a total of 12 calculation codes.

Algorithms↗

Validation of a personalized dosimetric evaluation tool (Oedipe) for targeted radiotherapy based on the Monte Carlo MCNPX code.

Dosimetric studies are necessary for all patients treated with targeted radiotherapy. In order to attain the precision required, we have developed Oedipe, a dosimetric tool based on the MCNPX Monte Carlo code. The anatomy of each patient is considered in the form of a voxel-based geometry created using computed tomography (CT) images or magnetic resonance imaging (MRI). Oedipe enables dosimetry studies to be carried out at the voxel scale. Validation of the results obtained by comparison with existing methods is complex because there are multiple sources of variation: calculation methods (different Monte Carlo codes, point kernel), patient representations (model or specific) and geometry definitions (mathematical or voxel-based). In this paper, we validate Oedipe by taking each of these parameters into account independently. Monte Carlo methodology requires long calculation times, particularly in the case of voxel-based geometries, and this is one of the limits of personalized dosimetric methods. However, our results show that the use of voxel-based geometry as opposed to a mathematically defined geometry decreases the calculation time two-fold, due to an optimization of the MCNPX2.5e code. It is therefore possible to envisage the use of Oedipe for personalized dosimetry in the clinical context of targeted radiotherapy.

Computer Simulation↗

Microdosimetry of radon progeny alpha particles in bronchial airway bifurcations.

A Monte Carlo code, initially developed for the calculation of microdosimetric spectra for alpha particles in cylindrical airways, has been extended to allow the computation of microdosimetric parameters for multiple source-target configurations in bronchial airway bifurcations. The objective of the present study was to investigate the effects of uniform and non-uniform radon progeny surface activity distributions in symmetric and asymmetric bronchial airway bifurcations on absorbed dose, hit frequency, lineal energy, single hit specific energy and LET spectra. In order to assess the effects of multiple hits, dose-dependent specific energy spectra were calculated by solving the compound Poisson process by iterative convolution. While the simulations showed significant differences of cellular dose quantities at different cell locations for uniformly distributed surface activities, even higher variations, as high as several orders of magnitude, were observed for non-uniform surface activity distributions, depending on the location of the cell and the local activity distribution.

Air Pollutants, Radioactive↗

Microdosimetry of inhomogeneous radon progeny distributions in bronchial airways.

A Monte Carlo code, initially developed for the calculation of microdosimetric spectra for alpha particles in cylindrical airways, has been extended to allow the computation (i) of additional microdosimetric parameters and (ii) for realistic exposure conditions in human bronchial airways with respect to surface activity distribution and airway geometry. The objective of the present study was to investigate the effects of non-uniform distributions of radon progeny activities in bronchial airways on cellular energy deposition parameters. Significant variations of hit frequencies, doses and microscopic energy deposition patterns were observed for epithelial cell nuclei, depending strongly on the assumed activity distributions. Thus, epithelial cells located at different positions in a given bronchial airway may experience a wide range of biological responses. The results obtained suggest that the hit frequency may be the primary physical parameter for alpha particles, supplemented by microdosimetric single event spectra, to be related to biological effects for chronic low level exposures.

Administration, Inhalation↗

Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources.

This paper aims at comparing dosimetric assessments performed with three Monte Carlo codes: EGS4, MCNP4c2 and MCNPX2.5e, using a realistic voxel phantom, namely the Zubal phantom, in two configurations of exposure. The first one deals with an external irradiation corresponding to the example of a radiological accident. The results are obtained using the EGS4 and the MCNP4c2 codes and expressed in terms of the mean absorbed dose (in Gy per source particle) for brain, lungs, liver and spleen. The second one deals with an internal exposure corresponding to the treatment of a medullary thyroid cancer by 131I-labelled radiopharmaceutical. The results are obtained by EGS4 and MCNPX2.5e and compared in terms of S-values (expressed in mGy per kBq and per hour) for liver, kidney, whole body and thyroid. The results of these two studies are presented and differences between the codes are analysed and discussed.

Computer Simulation↗

Current developments at IRSN on computational tools dedicated to assessing doses for both internal and external exposure.

The paper presents the OEDIPE (French acronym that stands for tool for personalised internal dose assessment) and SESAME (for simulation of external source accident with medical images) computational tools, dedicated to internal and external dose assessment, respectively, and currently being developed at the Institute for Radiological Protection and Nuclear Safety. The originality of OEDIPE and SESAME, by using voxel phantoms in association with Monte Carlo codes, lies in their ability to construct personalised voxel phantoms from medical images and automatically generate the Monte Carlo input file and visualise the expected results. OEDIPE simulates in vivo measurements to improve their calibration, and calculates the dose distribution taking both internal contamination and internal radiotherapy cases into account. SESAME enables radiological overexposure doses to be reconstructed, as also victim, source and accident environment modelling. The paper presents the principles on which these tools function and an overview of specificities and results linked to their fields of application.

Academies and Institutes↗

A computational tool based on voxel geometry for dose reconstruction of a radiological accident due to external exposure.

In the case of overexposure to ionising radiation, estimation of the absorbed dose in the organism is an important indicator for evaluating the biological consequences of this exposure. The physical dosimetry approach is based either on real reconstruction of the accident, using physical phantoms, or on calculation techniques. Tools using Monte Carlo simulations associated with geometric models are very powerful since they offer the possibility to simulate faithfully the victim and the environment for dose calculations in various accidental situations. Their work presents a new computational tool, called SESAME, dedicated to dose reconstruction of radiological accidents based on anthropomorphic voxel phantoms built from real medical images of the victim in association with the MCNP Monte Carlo code. The utility was, as a first step, validated for neutrons by experimental means using a physical tissue-equivalent phantom.

Algorithms↗

Application of new imaging and calculation techniques to activity and dose assessment in the case of a 106Ru contaminated wound.

The aim of this paper is to describe the dosimetric evaluation of a point contamination that occurred in a laboratory during the examination of an irradiated sample. The incident led to point contamination of the operator's finger due to the presence of mainly 106Ru, with its progeny, 106Rh. The paper reports on the activity and dose assessment, performed using several methods. The measured activity was obtained using a conventional device based on a germanium detector and confirmed using software developed at IRSN, based on reconstruction of voxel phantom associated with the Monte Carlo N-Particle code (MCNP) for in vivo measurement. Two dose assessment calculations were performed using both analytical and Monte Carlo methods, applying the same approach as for activity assessment based on the personal computational phantom of the finger. The results are compared, followed by a discussion on the suitability of the tools described in this study.

Computer Simulation↗