PubMed Health⌕ Search

Biomedical subjects

I Balásházy

Publications and source records attributed to I Balásházy.

6 recordsLinked to original sources

Detailed mathematical description of the geometry of airway bifurcations.

Health effects related to the deposition of inhaled aerosol particles in the respiratory system strongly depend on the local deposition patterns. These patterns are highly sensitive to the shape of the airway geometry. The current study presents an exact mathematical description of a morphologically realistic airway bifurcation by further developing an earlier study of the published literature. In addition, numerical methods are elaborated to solve some important tasks, which are necessary for the development of computational fluid dynamics (CFD) techniques in the area of aerosol deposition calculations in the airways. Finally, single and multiple airway geometries and computational grids are generated and analysed.

Aerosols↗

Etched track detectors and the low dose problem.

The risk to human health of exposure to low-level radiation is not precisely known yet. One way of studying this is to carry out in vitro biological experiments with cell cultures and to extend the conclusions to biological models. To relate the macroscopically deteminable 'low dose' to the damage of cells caused by a certain type of ionising particle is nearly impossible. therefore the number of hits and the imparted energy are the significant quantities. They can be estimated by particle transport calculations and by direct measurements. The effect of low dose was investigated in radio-adaptation experiments when mono-layers of different unsynchronised cell cultures were irradiated by neutrons produced in the filtered beam of the Budapest Research Reactor (BRR). The energy deposition was investigated by replacing the mono-layers with etched track detectors of the CR-39 type.

Adaptation, Physiological↗

Simulation of deposition and clearance of inhaled particles in central human airways.

In this study local distributions of deposited inhaled particles such as radon progenies in realistic human airway bifurcation models of bronchial generations one to six are computed for different geometries, inlet flow profiles, flow rates and particle sizes with computational fluid particle dynamics methods. The movement of the mucus layer in the large central human airways is also simulated by computational fluid dynamic techniques. There is experimental evidence that bronchogenic carcinomas mainly originate at the central zone of the large airway bifurcations, where primary hot-spots of deposition have been found. However, current lung deposition models do not take into consideration the inhomogeneity of deposition within the airways. The inhomogeneous movement of the mucus layer may strongly influence the effect of primary deposition. On the basis of our results, both the deposition and the clearance patterns are highly non-uniform, especially in the vicinity of the carinal ridge of the bifurcations.

Absorption↗

Modelling carcinogenic effects of low doses of inhaled radon progenies.

In this study, cellular hit probabilities of alpha particles emitted by inhaled radon progenies in sensitive epithelial cell nuclei were simulated at low exposure levels to obtain useful data for the rejection or in support of the linear no-threshold dose-effect hypothesis. In this work, local distributions of deposited inhaled radon progenies in airway bifurcation models were computed at exposure conditions which are characteristic of homes and uranium mines. Then, maximum local deposition enhancement factors, that is, local per average deposition densities, were simulated, and the effects of the inhomogeneity of deposition on hit probabilities were characterised. Our results suggest that in the vicinity of the carinal regions of the central airways the probability of multiple hits can be quite high even at low doses.

Administration, Inhalation↗

Local deposition distributions of inhaled radionuclides in the human tracheobronchial tree.

There is experimental evidence that bronchogenic carcinomas originate mainly at the carinal ridges of the large central airways, where primary hot spots of deposition have been found. However, current lung dosimetry models do not take into consideration the inhomogeneity of deposition within the airways. In this study, computed local distributions of deposited inhaled radionuclides such as radon progenies in morphologically realistic human airway bifurcation models are analysed for different flow rates and particle sizes. Then, local deposition enhancement factors, defined as the ratio of local to average deposition densities, are computed by scanning along the surface of the bifurcation with pre-specified surface area elements. Computed enhancement factors indicate that cells located at carinal ridges or at the inner sides of the progeny branches may receive localised doses which are two orders of magnitude higher than the average values.

Administration, Inhalation↗

Quantification of local deposition patterns of inhaled radon decay products in human bronchial airway bifurcations.

Aerosol deposition studies with tracheobronchial casts and models have demonstrated that inhaled particles are preferentially deposited within transitional bifurcation zones, exhibiting hot spots in the vicinity of carinal ridges. The goal of the present study is to quantify the inhomogeneity of theoretically predicted deposition patterns by local deposition enhancement factors. First, inspiratory particle deposition patterns of unattached (1 nm), ultrafine (10 nm and 20 nm), and attached (100 nm and 200 nm) radon progeny within three-dimensional models of segmental bronchial airway bifurcations were simulated by a numerical fluid dynamics and particle trajectory model. Second, local deposition enhancement factors were computed by scanning along the surface of the bifurcation models with prespecified surface area elements. Maximum values and frequency distributions of local deposition enhancement factors of inhaled radon progeny were derived for different sizes of the scanning element in a "narrow" and a "physiologically realistic" bifurcation model and for two different flow rates (10 L min(-1) and 60 L min(-1) in the trachea). Computed enhancement factors indicate that cells located at carinal ridges may receive localized doses which are 20-40 times (1 nm) and 50-115 times higher (10 nm-200 nm), respectively, than the corresponding average doses. This may have important implications for the microdosimetry of inhaled radon progeny and the resulting lung cancer risk.

Aerosols↗