PubMed HealthSearch

Biomedical subjects

I C Forster

Publications and source records attributed to I C Forster.

13 recordsLinked to original sources

Activation, inactivation and recovery in the sodium channels of the squid giant axon dialysed with different solutions.

Comparisons were made between families of ion currents recorded in voltage-clamped squid axons dialysed with 20 mM NaF and 330 mM CsF or TMAF, and bathed in a solution in which four fifths of the Na was replaced by Tris. The permeability coefficient PNa,fast for the fast-inactivating current in the initial open state was calculated as a function of test potential from the size of the initial peak of INa. The permeability coefficient PNa,non for the non-inactivating open state was calculated from the steady-state INa that persisted until the end of the test pulse. Dialysis with TMA had no direct effect on the QV curve for gating charge. The reversal potential for INa,non was always lower than that for INa,fast, the mean difference being about -9 mV when dialysing with Cs, but only about -1 mV with TMA. Except close to threshold, PNa,fast was roughly halved by dialysis with TMA as compared with Cs, but PNa,non was substantially increased. The time constant tau h inactivation of the sodium system was slightly increased during dialysis with TMA in place of Cs, and there were small shifts in the steady-state inactivation curve, but the rate of recovery from inactivation was not measurably altered. The flattening off of the tau h curve at increasingly positive test potentials corresponded to a steady reduction of the apparent inactivation charge until a value of about 0.2e was reached for pulses to 100 mV. The instantaneous I-V relationship in the steady state was also investigated. The results have a useful bearing on the effects of dialysis with TMA, on the differences between the initial and steady open states of the sodium channel, and on the relative voltage-dependences of the transitions in each direction between the resting and inactivated states.

Animals

The early phase of sodium channel gating current in the squid giant axon. Characteristics of a fast component of displacement charge movement.

A fast component of displacement current which accompanies the sodium channel gating current has been recorded from the membrane of the giant axon of the squid Loligo forbesii. This component is characterized by relaxation time constants typically shorter than 25 microseconds. The charge displaced accounts for about 10% (or 2 nC/cm2) of the total displacement charge attributed to voltage-dependent sodium channels. Using a low noise, wide-band voltage clamp system and specially designed voltage step protocols we could demonstrate that this component: (i) is not a recording artifact; (ii) is kinetically independent from the sodium channel activation and inactivation processes; (iii) can account for a significant fraction of the initial amplitude of recorded displacement current and (iv) has a steady state charge transfer which saturates for membrane potentials above +20 mV and below -100 mV. This component can be modelled as a single step transition using the Eyring-Boltzmann formalism with a quantal charge of 1 e- and an asymmetrical energy barrier. Furthermore, if it were associated with the squid sodium channel, our data would suggest one fast transition per channel. A possible role as a sodium channel activation trigger, which would still be consistent with kinetic independence, is discussed. Despite uncertainties about its origin, the property of kinetic independence allows subtraction of this component from the total displacement current to reveal a rising phase in the early time course of the remaining current. This will have to be taken into account when modelling the voltage-dependent sodium channel.

Animals

The effect of tetrodotoxin on the sodium gating current in the squid giant axon.

The effect of tetrodotoxin (TTX) on the sodium gating current in the squid giant axon was examined by recording the current that flowed at the pulse potential at which the ionic current fell to zero, first in the absence and then in the presence of TTX. The addition of 1 microM TTX to the bathing solution had no consistent effect on the size of the initial peak of the gating current, but resulted in small changes in the timecourse of its subsequent relaxation which were mainly caused by a reduction of about one quarter in the component that has a delayed onset and may possibly arise from changes in the state of ionization of groups in the channel wall when the lumen fills with water. Our findings suggest that the binding of TTX at the outer face of the sodium channel does not interfere with the mechanisms of activation and inactivation by the voltage sensors, but has an allosteric effect on the access of internal cations to the inside of the channel.

Animals

The quantal gating charge of sodium channel inactivation.

Using a very low noise voltage clamp technique it has been possible to record from the squid giant axon a slow component of gating current (Ig) during the inactivation phase of the macroscopic sodium current (INa) which was hitherto buried in the baseline noise. In order to examine whether this slow Ig contains gating charge that originates from transitions between the open (O) and the inactivated (I) states, which would indicate a true voltage dependence of inactivation, or whether other transitions contribute charge to slow Ig, a new model independent analysis termed isochronic plot analysis has been developed. From a direct correlation of Ig and the time derivative of the sodium conductance dgNa/dt the condition when only O-I transitions occur is detected. Then the ratio of the two signals is constant and a straight line appears in an isochronic plot of Ig vs. dgNa/dt. Its slope does not depend on voltage or time and corresponds to the quantal gating charge of the O-I transition (qh) divided by the single channel ionic conductance (gamma). This condition was found at voltages above -10 mV up to +40 mV and a figure of 1.21 e- was obtained for qh at temperatures of 5 and 15 degrees C. At lower voltages additional charge from other transitions, e.g. closed to open, is displaced during macroscopic inactivation. This means that conventional Eyring rate analysis of the inactivation time constant tau h is only valid above -10 mV and here the figure for qh was confirmed also from this analysis. It is further shown that most of the present controversies surrounding the voltage dependence of inactivation can be clarified. The validity of the isochronic plot analysis has been confirmed using simulated gating and ionic currents.

Animals

Kinetic analysis of the sodium gating current in the squid giant axon.

A critical study has been made of the characteristics of the kinetic components of the sodium gating current in the squid giant axon, of which not less than five can be resolved. In addition to the principal fast component Ig2, there are two components of appreciable size that relax at an intermediate rate, Ig3 alpha and Ig 3 beta. Ig3 alpha has a fast rise, and is present over the whole range of negative test potentials. Ig3 beta is absent below -40 mV, exhibits a delayed onset and disappears on inactivation of the sodium system. There are also two smaller components, Ig1 and Ig4, with very fast and much slower relaxation time constants, respectively.

Animals

High resolution recording of asymmetry currents from the squid giant axon: technical aspects of voltage clamp design.

The design, realisation and performance of a voltage clamp system dedicated to recording asymmetry currents from the squid giant axon is presented. The design has been optimised with respect to dynamic response, signal-to-noise ratio and linearity. Analytical expressions are given for both the dynamic performance and noise characteristics which simplify the design and setting up of the clamp and provide excellent agreement between design theory and practice. A 0.5 cm2 area of membrane can be voltage clamped in response to a command input voltage step within 10 microseconds with smooth settling and up to 100% of the effective series resistance being compensated. The noise contributions of the recording chamber, voltage sensing electrodes and clamp electronics have been reduced such that recording of gating currents with a more than 10-fold reduction in the number of averages required compared with previous clamp designs is possible. The overall system nonlinearity results in typically less than 1% contribution to the measured asymmetry charge.

Animals

Gating current associated with inactivated states of the squid axon gating channel.

Sodium (Na) channel gating currents were measured in squid (Loligo forbesi) axons to study transitions among states occupied by the Na channel when it is inactivated. These measurements were made at high temporal resolution with a low-noise voltage clamp. The inactivation-resistant gating current, I(g,inact), could be separated into a very fast (tau = 5-25 mus) and a slower (tau = 40-200 mus) component over a wide range of test potentials (-140 mV to 80 mV) and for three different starting potentials (-70 mV, 0 mV, and 50 mV). The time constants for these components plotted against test potential lay on two bell-shaped curves; the time constants at any particular test potential did not depend on the starting potential. Both components had charge-voltage curves that saturated between -150 mV and 50 mV. A fast spike, similar to the fast component of I(g, inact), was also apparent in recordings of the fully recovered total "on" gating current. I(g, inact)(fast) and I(g, inact)(slow) could not together be described by the simplest possible model, a linear three-state scheme; however, I(g, inact)(fast) could be modeled by a two-state scheme operating in parallel with other gating processes. I(g, inact)(slow) and the gating current due to recovery from inactivated states into resting states could together be well described by a three-state scheme. This lends support to models in which a pair of inactivated states are connected by a single voltage-dependent step to the resting states of the Na system.

Animals

Single-channel current simulation and recording using a photodiode as current generator.

A device which can generate rectangular currents in the picoampere range is described. The current generator is a photodiode connected to the head stage of a single-channel recording amplifier. The photodiode is activated by a light-emitting diode controlled by a computer or any other current source. The device can transmit signals corresponding to simulated single-channel behaviour. Since the kinetic parameters of the simulation are known, the user can test the data acquisition and analysis system under conditions similar to those prevailing during recording from a biological membrane. This current generator can also be used for the tuning of patch-clamp amplifiers; rectangular currents generated by the photodiode allow the frequency response of the amplifier to be properly adjusted.

Electric Stimulation

Technical aspects of voltage-clamping the cut-open squid giant axon.

The design of a voltage-clamp system dedicated to recording the fluctuation of sodium currents under non-stationary conditions from a leaflet of cut-open squid axon is presented. The membrane leaflet is mechanically sandwiched between the apices of two finely machined plexiglass cones which enable fluid access to each side of the membrane and a known area of membrane to be voltage-clamped. The design requirements necessary to achieve satisfactory signal resolution have been assessed in terms of the overall digitising resolution of the ADC hardware and the intrinsic and extrinsic components of the clamp-system noise. Good agreement between the predicted and measured noise performance was found. The clamp system has enabled simultaneous estimates of the single-channel conductance and channel density to be made over a much wider range of experimental conditions than previously possible.

Animals

A multiple-electrode hearing prosthesis for cochlea implantation in deaf patients.

A multiple-electrode hearing prosthesis for cochlea implantation in deaf patients has been developed at the University of Melbourne. It has been designed as a multiple-electrode implant to provide the best chance of enabling patients to understand speech. It has been shown that an electrode array can be threaded along the coills of the inner ear close to residual auditory nerves. Experimental studies have indicated that the long-term implantation of the array will not lead to significant degeneration of auditory nerve fibres. Loss of platinum from the stimulating electrodes can be minimized with a biphasic constant current pulse, where the first phase is negative with respect to ground. The receiver-stimulator component has also been designed to provide 10-15 channels of stimulation. Furthermore, the phase and amplitude of the stimuli to individual electrodes can be varied to enable the localization of the electrical fields to discrete groups of nerve fibres, and the correct method of frequency and intensity coding to be determined. Finally, the device should be used in the first instance for a specially selected group of adults who are post-lingually deaf.

Animals

A multiple electrode cochlear implant.

The University of Melbourne Departments of Otolaryngology and Electrical Engineering (UMDOLEE) receiving and stimulating component of a multiple-electrode cochlear implant hearing prosthesis produces constant stimulation. It has a stimulating pulse shape that minimizes the production of toxic substances and loss of metal from the electrodes, and this is achieved with a biphasic rectangular waveform where the first phase is negative with respect to ground. The duration of each stimulus phase in 180 msec, which is long enough to allow low levels of current stimulation, and short enough to permit rates of 1000 pulses/second to be achieved. In order to be consistent with our present understanding of the perception of pitch, the device permits the independent stimulation of a number of electrodes. Furthermore, to electrically isolate the stimulus to small areas, there is the capacity to vary the current and set the threshold independently at individual electrodes. The phase and amplitude of the pulses to neighbouring electrodes with also be varied to assist in localizing the current flow. The pattern to stimulation to individual or groups of electrodes can also be altered to enable studies to be carried out to determine ways of conveying frequency and intensity information over a more normal dynamic range.

Animals