PubMed Health⌕ Search

Biomedical subjects

I Castiglioni

Publications and source records attributed to I Castiglioni.

10 recordsLinked to original sources

Early diagnosis of Alzheimer's disease using a grid implementation of statistical parametric mapping analysis.

A quantitative statistical analysis of perfusional medical images may provide powerful support to the early diagnosis for Alzheimer's Disease (AD). A Statistical Parametric Mapping algorithm (SPM), based on the comparison of the candidate with normal cases, has been validated by the neurological research community to quantify ipometabolic patterns in brain PET/SPECT studies. Since suitable "normal patient" PET/SPECT images are rare and usually sparse and scattered across hospitals and research institutions, the Data Grid distributed analysis paradigm ("move code rather than input data") is well suited for implementing a remote statistical analysis use case, described in the present paper. Different Grid environments (LCG, AliEn) and their services have been used to implement the above-described use case and tackle the challenging problems related to the SPM-based early AD diagnosis.

Algorithms↗

Shared cortical anatomy for motor awareness and motor control.

In everyday life, the successful monitoring of behavior requires continuous updating of the effectiveness of motor acts; one crucial step is becoming aware of the movements one is performing. We studied the anatomical distribution of lesions in right-brain-damaged hemiplegic patients, who obstinately denied their motor impairment, claiming that they could move their paralyzed limbs. Denial was associated with lesions in areas related to the programming of motor acts, particularly Brodmann's premotor areas 6 and 44, motor area 4, and the somatosensory cortex. This association suggests that monitoring systems may be implemented within the same cortical network that is responsible for the primary function that has to be monitored.

Adult↗

A publicly accessible Monte Carlo database for validation purposes in emission tomography.

Monte Carlo (MC) methods provide ideal data sets to assess reconstruction and correction techniques in emission tomography (ET). Although several ET-dedicated MC codes are available, their use is hindered by the heavy computation burden required for high statistics simulations as well as by the need to adapt the code to the purpose of the individual user. In this work a publicly accessible database of MC-simulated ET data sets (the MC-ET database) was created and published on an Internet web site (http://www.ibfm.cnr.it/mcet/index.html), in order to provide MC-simulated data ready to be downloaded and used by researchers at different sites with similar evaluation purposes. At present, the MC-ET database provides direct access to MC-simulated raw data of unscattered, scattered and total events: (a) obtained by different MC codes, (b) relative to different radioactive sources, from simple geometrical phantoms to studies of normal and pathological subjects and (c) derived from different SPECT and PET scanners. The main features of the MC-ET data sets are: (a) validation by comparison with measured data, (b) classification according to pre-defined database characteristics, (c) common-use file format and (d) easy and free access and download.

Algorithms↗

Automatic registration of PET and CT studies for clinical use in thoracic and abdominal conformal radiotherapy.

AIM: Implementation and validation of an automatic registration method based on mutual information (MI) for the integration of thoracic and abdominal positron emission tomography (PET)/computed tomography (CT) studies, with the purpose to facilitate in a clinical context the inclusion of PET metabolic information in conformal radiotherapy (RT). METHODS: Registration was obtained by modeling a rigid spatial transformation between CT and PET transmission studies. The registration method was based on Normalized Mutual Information (NMI), by iteratively transforming the PET volume, until its optimal alignment to the CT study is achieved, in correspondence of the maximum of NMI. To avoid entrapment in local maxima and to improve convergence speed we introduced a multiresolution scheme. Accuracy of the proposed approach was investigated in experimental data, relative to phantom and patient studies, acquired in conditions similar to clinical situations. RESULTS: In phantom studies the mean error in the 3D space is 3.6 mm (range 3-4 mm) in thoracic region and 3.2 mm (range 2.9-3.7 mm) in abdominal region, considerably less than PET spatial resolution. In patient studies the spatial mean error increases with respect to phantom studies (5.4 mm and 5.2 mm for thorax and abdomen, respectively) but remains comparable to the PET spatial resolution. The accuracy of spatial realignment was thus found adequate for the registration of PET/CT registration, if good patient repositioning was adopted. CONCLUSIONS: The proposed registration method, based on MI, was validated for the integration of PET/CT studies of patients candidate for thoracic and abdominal conformal RT. The method is automatic and provided with a user interface, thus suitable for clinical use.

Abdominal Neoplasms↗

Multi-modal medical image integration to optimize radiotherapy planning in lung cancer treatment.

This work presents a method for CT and PET image registration, and multi-modal analysis, to optimize radiotherapy planning in lung cancer treatment. The method relies on an image registration technique based on fiducial external markers to realign, spatially, PET images with the CT spatial reference system. The method was set up for clinical use in radiotherapy, allowing minimal modifications to be introduced in the management of patients undergoing radiation treatment. The accuracy of the registration technique was evaluated on patient studies in terms of Target Registration Error and was found to be less than 6.40 mm. The method was applied in the treatment planning of five patients affected by non-small-cell lung cancer, revealing the usefulness of PET/CT integration in delineating the extension of both the tumor mass and the tissues involved in the neoplastic process. Moreover, the functional information provided by PET often led to alterations in the treatment planning, changing the size and/or direction of radiation portals. The proposed method for PET/CT integration has been confirmed as being useful for optimizing radiotherapy planning in lung cancer treatment.

Algorithms↗

Monte Carlo simulations in SPET and PET.

Monte Carlo methods are extensively used in Nuclear Medicine to tackle a variety of problems that are difficult to study by an experimental or analytical approach. A review of the most recent tools allowing application of Monte Carlo methods in single photon emission tomography (SPET) and positron emission tomography (PET) is presented. To help potential Monte Carlo users choose a code, we present advantages and disadvantages of the different types of Monte Carlo codes currently available for SPET and PET, discuss common and specific features of the codes, classify the codes with respect to these features, comment key properties for a code to be appropriate for a given purpose and, at last, we consider the possibility of going towards a standardisation of the description of the codes which could facilitate their comparison.

Computer Simulation↗

Acupuncture produces central activations in pain regions.

Acupuncture is largely used for pain control in several pathological conditions. Its effects on the central nervous system are not well defined. We investigated the effect of the application of acupuncture to 13 normal subjects (males, 21-32 years). H2(15)O bolus PET scans were read before the application of the needles (Rest, R) and after 25 min of needle insertion. Data were acquired by scanning in 3-D mode. The acupuncture application, true acupuncture (TA), was alternated to a placebo needle application (PA) in two different sequences (seven and six subjects, respectively), either R,PA,R, TA or R,TA,R,PA, a period of 15 min being left after every first TA or PA to allow for the recovery of basal conditions. Here we show that classic acupuncture activates the left Anterior Cingulus, the Insulae bilaterally, the Cerebellum bilaterally, the left Superior Frontal Gyrus, and the right Medial and Inferior Frontal Gyri. Most of the activated areas are shared with areas activated in acute and chronic pain states as described in the literature. Thus acupuncture appears to act by activating areas also involved in pain. This indicates that acupuncture could relief pain by unbalancing the equilibrium of distributed pain-related central networks.

Acupuncture Points↗

An automatic classification technique for attenuation correction in positron emission tomography.

In this paper a clustering technique is proposed for attenuation correction (AC) in positron emission tomography (PET). The method is unsupervised and adaptive with respect to counting statistics in the transmission (TR) images. The technique allows the classification of pre- or post-injection TR images into main tissue components in terms of attenuation coefficients. The classified TR images are then forward projected to generate new TR sinograms to be used for AC in the reconstruction of the corresponding emission (EM) data. The technique has been tested on phantoms and clinical data of brain, heart and whole-body PET studies. The method allows: (a) reduction of noise propagation from TR into EM images, (b) reduction of TR scanning to a few minutes (3 min) with maintenance of the quantitative accuracy (within 6%) of longer acquisition scans (15-20 min), (c) reduction of the radiation dose to the patient, (d) performance of quantitative whole-body studies.

Brain↗

Functional heterogeneity of left inferior frontal cortex as revealed by fMRI.

Using functional magnetic resonance imaging (fMRI), we mapped brain activity in six normal volunteers during two silent verbal fluency tasks, one with a phonemic (letter) cue and one with a semantic (category) cue. In comparison with resting state, both tasks activated the anterior triangular portion of the left inferior frontal gyrus (IFG or F3, for third frontal gyrus) and the left thalamus. There were also areas activated in one task but not in the other: the posterior opercular portion of the left IFG for phonemic fluency, and the left retrosplenial region for semantic fluency. Our findings concur with normal psychophysical data and neuropsychological observations to suggest the recruitment of two overlapping but dissociable systems for the two tasks, and demonstrate functional heterogeneity within the left IFG (Broca's area), where the opercular portion is responsible for obtaining access to words through a phonemic/articulatory route.

Adult↗

Evaluation of pre- and post-reconstruction count-dependent Metz filters for brain PET studies.

In this study we evaluated pre- (PR-R) and post-reconstruction (PO-R) count-dependent Metz filters for PET brain studies in order to increase signal-to-noise ratio. A set of studies using a 3D Hoffman brain phantom was performed at various count levels, and a reference image set was created from extremely high count images. Several combinations of PR-R and PO-R filtering were considered to find the optimal means of processing, including: Hann filter alone; PR-R Metz filter without or with a PO-R low pass filter; and PO-R Metz filter without or with a PR-R low pass filter. A formula was established to correlate the optimal PO-R Metz filter order with the net counts. Resolution [full width at half-maximum (FWHM) and fill width at tenth maximum (FWTM)], normalized residual mean square differences (NRMSD) between the ideal and the processed images, noise reduction and contrast were used as parameters for the evaluation of the different filter combinations. Resolution is decreased by all filter combinations that can effectively control noise; however, FWTM increases less than FWHM. NRMSD indicates that the use of Hann and (optimal) PO-R Metz filter is the most powerful combination from among those tested. A close correlation (r = 0.969) was found between the net counts and the optimal order of the PO-R Metz filter. At the count levels of clinical studies the PO-R Metz filter was found to control noise much more effectively and enhance the contrast when compared to the routinely used Hann filter alone, and produced images of better quality.

Biophysical Phenomena↗