Premature ventricular contraction classification by the Kth nearest-neighbours rule.

An analysis of electrocardiographic pattern recognition parameters for premature ventricular contraction (PVC) and normal (N) beat classification is presented. Twenty-six parameters were defined: 11 x 2 for the two electrocardiogram (ECG) leads, width of the complex and three parameters derived from a single-plane vectorcardiogram (VCG). Some of the parameters include amplitudes of maximal positive and maximal negative peaks, area of absolute values, area of positive values, area of negative values, number of samples with 70% higher amplitude than that of the highest peak, amplitude and angle of the QRS vector in a VCG plane. They were measured for all heartbeats annotated as N or PVC in all 48 ECG recordings of the MIT-BIH arrhythmia database. Two reference sets for the Kth nearest-neighbours rule were used-global and local. The classification indices obtained with the global reference set were 75.4% specificity and 80.9% sensitivity. Using the local reference set we increased the specificity to 96.7% and the sensitivity to 96.9%. The achieved specificity and sensitivity are comparable with, and greater than, the results reported in the literature.

Data Interpretation, Statistical↗

Ranking of pattern recognition parameters for premature ventricular contractions classification by neural networks.

Detection and classification of ventricular complexes from a limited number of ECG leads is of considerable importance in critical care or operating room patient monitoring. Beat-to-beat detection allows the heart rhythm evolution to be followed and various types of arrhythmia to be recognized. A quantitative analysis is proposed of pattern recognition parameters for classification of normal QRS complexes and premature ventricular contractions (PVC). Twenty-six parameters have been defined: the width of the QRS complex, three vectorcardiogram parameters and 11 from two ECG leads. These parameters include: amplitudes of positive and negative peaks, area of positive and negative waves, various time-interval durations, amplitude and angle of the QRS vector, etc. They are measured for all QRS complexes annotated as 'normals' and 'PVCs' from the 48 ECG recordings of the MIT-BIH arrhythmia database. Neural networks (NN) are shown to be a useful instrument for the analysis of large quantities of parameters. Separate ranking of any parameter and homogeneous group ranking (amplitude, area, interval, slope and vector) were performed. From the two ECG leads, the first three ranked parameter groups for clustering of PVCs are amplitude, slope and interval, while for N clustering they are vector, amplitude and area. Considering the entire parameter set, we obtained N = 99.7% correct detection of normal QRS complexes and PVC = 98.5% of premature ventricular complexes. The study also shows that simultaneous analysis of two ECG channels yields better accuracy compared to using a single channel: the improvement is 0.1% in the classification of N beats and 4.5% for PVC beats.

Databases, Factual↗

Modulation of steroidogenesis in human ovarian granulosa cells during aging.

OBJECTIVE: To investigate the in vitro effect of endothelin-1 (ET-1) on the steroid production (progesterone [P] and estradiol [E2]) by cultured human granulosa cells (GCs) during aging. MATERIAL AND METHODS: Human ovarian GCs and granulosa-luteal cells (GLCs) were isolated from ovaries of female patients (young and premenopausal) undergoing surgery for non-ovarian benign gynecological conditions. Cells were cultured with ET-1 in the presence or in the absence of FSH. The concentrations of P and E2 in conditioned media were determined by means of RIA. RESULTS: In human GCs and GLCs obtained from young and premenopausal women, ET-1 in vitro can significantly reduce the FSH stimulated biosynthesis of P, whereas the basal P biosynthesis is only insignificantly diminished. The in vitro application of ET-1 have only a sparse inhibitory effect on both the basal and FSH stimulated biosynthesis of E2 in GCs from the two patient groups. CONCLUSIONS: Our findings support the opinion that ET-1 is a local regulator of ovarian steroidogenesis which might modulate the steroid production and the stimulatory effect of FSH in cultured GCs and GLCs obtained from women at various ages.

Adult↗

In-house development of test equipment for quality control and training. Case study: a prototype ECG simulator-tester.

The support services for biomedical technology address a variety of technical and administrative issues, concerning the safe and efficient operation of medical equipment over the period of its intended use and the training of hospital personnel in issues concerning safety and quality. Clinical Engineering Departments undertake the responsibility of developing and operating training programs in medical equipment utilisation apart from the traditional role of training and supervising technicians involved in testing, calibration and preventive/corrective maintenance of electromedical equipment. In view of the above, the Institute of Biomedical Technology and the Centre of Biomedical Engineering collaborated for the design and development of a prototype digital ECG and arrhythmia simulator. In the absence of internationally accepted inspection protocols for ECG simulators, the verification phase of the project involved mainly the inspection of the device's conformity to its initial technical specifications. The results demonstrated that this tester. due to simplicity in construction and easiness of use could be a practical, reliable and economical solution for electrocardiograph and ECG monitor testing and waveform recognition training.

Arrhythmias, Cardiac↗

High-pass filtering of the electrogastrogram.

The recording and processing of an electrogastrogram require adequate band-pass filtering, to suppress unwanted artefacts but preserve the original signal waveform. High-pass filtering of various types, of different time constants tau, filter order, analogue and digital implementation, have been used to obtain higher baseline stability and faster signal recovery after strong artefacts. Special attention should be given to possible signal amplitude and phase distortions due to high-pass filtering, which can strongly influence accurate amplitude measurements or studies of signal propagation from multichannel recordings. Synthesised and original signals are used to demonstrate the effect of high-pass filtering. The use of a first-order filter with tau = 5 s is recommended for EGG studies if not especially directed to investigation of bradygastria. In the opposite case, tau = 15 s should be used, and with backward filtering a full restoration of the original signal can be obtained. The same is valid for recording the electrical activity of the colon. Lower time constants (tau = 5 s or less) can be applied to acquire signals from the small intestines. A radical solution is the use of a DC amplifier with controllable subtraction of the DC component.

Electromyography↗

Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation.

The measurement of successive RR intervals, obtained from the electrocardiogram (ECG), is the basis of any subsequent method for the assessment of variations in heart rate, for example using intervalograms, histograms, trend curves, spectral analysis, etc. The accuracy of measurement directly depends on the sampling rate used for the acquisition of the ECG signal. Depending on specific applications, rates down to 128 Hz are not uncommon. This considerably limits the resolution if RR interval data are to be derived. Interpolation is often employed for solving problems of this type. Linear, cubic and spline interpolations, obtained directly from the MATLAB software product, were applied and compared for the purpose of RR interval measurement. The cubic method was found to combine the improvement of resolution (+/-1 ms) at sampling rates successfully down to 100 Hz, with a rapid operating speed. Comparison examples are given with ECG signals acquired with 1000 Hz, 16-bit sampling.

Adult↗

Non-invasive electrogastrography. Part 1: Correlation between the gastric electrical activity in dogs with implanted and cutaneous electrodes.

Experiments were made on dogs with bipolar silver ball-shaped electrodes chronically implanted on the muscle wall of the stomach. The electrical activity of the gastric muscle wall (electrogastromyogram-EGMG) was characterized by slow potential changes during the quiescent period of the migrating myoelectric complex (MMC) and bursts of spike potentials during the activity period of MMC. Cutaneous (surface) electrodes were placed on the abdominal wall. Waves with a rhythm of 4.5-5 cpm were led off by the cutaneous electrodes (electrogastrogram-EGG), simultaneously with the EGMg. The bursts of spike potentials with the slow gastric potentials in the EGMG corresponded to an increase of the amplitude of the waves in the EGG. Good correlation was found between the number and frequency of spike potentials in a group and the wave amplitude in the EGG. EGG recorded on an electrogastrograph designed by us was characterized by low-amplitude waves corresponding to the slow waves during the period of quiescence of MMC and high-amplitude waves corresponding to the bursts of spike potentials during the activity period of MMC. Therefore it is possible to determine the MMC of the stomach by the changes in the amplitude of the waves in the EGG.

Action Potentials↗

Non-invasive electrogastrography. Part 2. Human electrogastrogram.

The electrical activity of human stomach muscle wall-electrogastrogram (EGG), was led off by surface (cutaneous) electrodes placed on the abdominal wall and recorded on an electrogastrograph. A method for complete elimination of the cardiac artefact was elaborated and successfully implemented. It consists of a preliminary elimination of the QRS complex, based on its higher amplitude and slope. The eliminated intervals were replaced by linear segments. A subsequent low-pass filtering allowed to obtain a high quality EGG signal. The electrical activity of the stomach of healthy volunteers was characterized by waves with a frequency of 3.35 +/- 0.09 cpm during the quiescent periods and 2.99 +/- 0.14 cpm during the activity periods of the migrating myoelectrical complex (MMC). Bearing in mind the correlation between the bursts of spike potentials with the slow waves in the dog EGMG and the high-amplitude waves, characterizing the periods of activity in the dog EGG, we can better differentiate the periods of quiescence and activity by the amplitude of the waves. The wave amplitude during periods of quiescence was 81.13 +/- 20.61 microV, significantly different from the wave amplitude during periods of activity being 164.74 +/- 43.34 microV (n = 7). Thus with this method in visual inspection it is possible to identify MMC of the human stomach by the changes in the amplitude of the waves in the EGG.

Action Potentials↗

A stable line of turkey bone marrow cells transformed by the myelocytomatosis virus strain MC31. Ultrastructural characteristics and localization of the DNA replication sites.

Attempts were made to characterize cells of the LSTC-SF2 line by scanning electron microscopy and transmission electron microscopy on the ultrastructural level. The virus-transformed cells are of oval, slightly elongated shape with an undulating surface. The cell nucleus is well outlined, poor in heterochromatin but with a strongly developed nucleolus. The cytoplasm is not rich in organelles except for an abundance of mitochondria with dense granules that are often found in them. With high-resolution autoradiography the DNA synthesis sites were identified mainly in proximity to the nuclear membrane and in the perinuclear spaces. The cells under study can be regarded as immature forms of the blood series and most likely as precursors of cells of the granulocyte or monocyte series.

Animals↗

Delayed hypersensitivity reactions in patients with breast cancer.

Fifty six patients with metastatic cancer of the breast (stage IV) were treated with Cyclophosphamide, 5-Fluorouracil and Cyclophosphamide + 5-Fluorouracil. Tests for delayed hypersensitivity to homologous tumor antigen before treatment were positive in 83.9% and negative in 16.1%. Response to DNCB was positive before treatment in 51.8% and negative in 48.2%. Following chemotherapy the skin reaction, to homologous tumor antigen remained positive, only in 12.6% and negative in 87.4%. The reaction of DNCB remained positive after treatment only in 17.8%. In the remaining 82.2% suppression of the reaction occurred. These data show that chemotherapy may suppress, to a certain excent, immune responses. It is established that among patients who have shown a positive reaction to homologous tumor antigen 55.3% of all cases have displayed objective response to the treatment, and among these with negative skin reactions objective responses were observed in 22.22% of all cases. In patients with positive DNCB reactions objective responses were observed in 79.3% and among the negative ones--in 37.4%.

Adult↗

Automatic detection of atrial fibrillation and flutter by wave rectification method.

Rapid detection of atrial flutter or fibrillation is needed in intensive care or home ECG monitoring with alarm generation, and in portable monitors with warningfunction, etc. Detection and assessment of these atrial abnormalities is necessary in computerized morphological analysis as well, to decide whether parameter measurements should be rejected, restricted to QRS and/or T wave only, or limited to those leads where atrial flutter orfibrillation waves are less expressed. A method for the detection and measurement of atrial flutter and fibrillation in the T-P segments of the ECG is proposed. An atrial flutter/ fibrillation parameter (AFF) is defined as the mean value of the differentiated filtered and rectified signal in these segments. The AFF has been measured in 329 patients from an annotated atrial flutter-fibrillation database. A threshold of AFF=0.35% with respect to the maximum signal excursion was chosen by a heuristic algorithm, to separate patients with atrial arrhythmia. The accuracy of the method was 91.8 %. The positive and negative detection errors of the AFF classification are discussed.

Atrial Fibrillation↗