Proton dosimetry intercomparison based on the ICRU report 59 protocol.

BACKGROUND AND PURPOSE: A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors. MATERIALS AND METHODS: Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations. RESULTS: The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type. CONCLUSIONS: Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.

Algorithms

An application of GafChromic MD-55 film for 67.5 MeV clinical proton beam dosimetry.

The purpose of this study is to explore the use of GafChromic MD-55 (RC) film for 67.5 MeV clinical proton beam dosimetry at the Crocker Nuclear Laboratory, University of California, Davis. Several strips of RC film 6 cm x 6 cm in dimension were irradiated at a depth of 18.2 mm corresponding to the middle of a 24 mm spread-out Bragg peak (SOBP). The films were irradiated to a proton dose in the range of 0.5 Gy to 100 Gy. The beam profiles were also measured at the middle of the 24 mm SOBP. The Bragg peak was measured by using a wedge shaped phantom made of Lucite. The Bragg peak measured with RC film was compared with diode and ionization chamber measurements. After background subtraction, the calibration of the dose response of RC film showed, to a maximum deviation of 10%, a linear increase of optical density (OD) with dose from 0.5 to 100 Gy. The uniformity of OD over a single sheet of film showed a variation of +/-6%. The distal-fall off between 90% and 20% measured with GafChromic film for the Bragg peak was 1.3 mm as compared to 1.1 mm for a diode measurement and 1.4 mm for an ionization chamber measurement. The FWHM of the Bragg peak was 7.5 mm when measured with GafChromic film, 5.3 mm when measured with a diode and 8.1 mm as measured by an ionization chamber. The peak/plateau ratio with GafChromic film was 3.3 as compared to 3.7 with a diode and 3.2 with an ionization chamber. In conclusion, GafChromic MD-55 film may be a useful and convenient detector for dose measurement and quality assurance programmes of proton beams.

Cyclotrons

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration

Experience in charged particle irradiation of tumors of the skull base: 1977-1992.

PURPOSE: To review the experience at University of California Lawrence Berkeley Laboratory in using charged particles to irradiate primary neoplasms of the skull base and those extending to the skull base from the nasopharynx and paranasal sinuses. METHODS AND MATERIALS: During the period from 1977 to 1992, 223 patients were irradiated with charged particles at the Lawrence Berkeley Laboratory for tumors either arising in or extending to the skull base, of whom 48 (22%) had recurrent lesions, either post previous surgery or radiotherapy. One hundred twenty-six patients had lesions arising in the cranial base, mostly chordoma (53), chondrosarcoma (27), paraclival meningioma (27) with 19 patients having other histologies such as osteosarcoma or neurofibrosarcoma. There were also 31 patients with primary or recurrent squamous carcinoma of the nasopharynx extending to the skull base, 44 patients with major or minor salivary gland tumors, mostly adenocarcinoma, and 22 patients with squamous carcinoma of the paranasal sinuses, all with cranial base extension. RESULTS: Local control and survival appeared improved in tumors arising in the skull base, following the ability with charged particles to deliver high doses (mean of 65 Gy-equivalent) with relative sparing of the adjacent normal tissues. The Kaplan-Meier 5-year local control was 85% for meningioma, 78% for chondrosarcoma, 63% for chordoma and 58% for other sarcoma. Follow-up ranged from 4-191 months with a median of 51 months. CONCLUSION: Charged particle radiotherapy is highly effective in controlling cranial base lesions which have have been partially resected. Better tumor localization with CT and MRI, improved 3-D treatment planning and beam delivery techniques have continued to reduce the level of serious complications and increase local control and survival.

Female

Charged particle radiotherapy of paraspinal tumors.

Between 1976 and 1987, 52 patients with tumors adjacent to and/or involving the cervical, thoracic, or lumbar spinal cord were treated with charged particles at the University of California Lawrence Berkeley Laboratory. The histologies included chordoma and chondrosarcoma (24 pts), other bone and soft tissue sarcoma (14 pts), and metastatic or unusual histology tumors (14 pts). Radiation doses ranged from 29 to 80 Gray-equivalent (GyE), with a median dose of 70 GyE. Twenty-one patients received a portion of their treatment with photons. Median followup was 28 months. For 36 previously untreated patients, local control was achieved in 21/36 patients and the 3-year actuarial survival was 61%. Of 16 patients treated for recurrent disease, 7/16 were locally controlled and the 3-year actuarial survival was 51%. For patients treated for chordoma and chondrosarcoma, probability of local control was influenced by tumor volume (less than 100 cc or greater than 150 cc) and whether disease was recurrent or previously untreated. Complications occurred in 6/52 patients, including one spinal cord injury, one cauda equina and one brachial plexus injury, and three instances of skin or subcutaneous fibrosis. Charged particle radiotherapy can safely deliver high tumor doses to paraspinal tumors with good local control.

Adolescent

Recurrent locally advanced nasopharyngeal carcinoma treated with heavy charged particle irradiation.

Between June 1981 and May 1990, 11 patients with recurrent locally advanced nasopharyngeal carcinoma were treated with heavy charged particle radiation at Lawrence Berkeley Laboratory. All patients had previously undergone full course radiotherapy to a median dose of 70.2 Gy [range 61-81 Gy]. Median time to recurrence was 18.2 months. At the time of heavy charged particle radiotherapy treatment, all had evidence of invasion of the base of skull and 7 of 11 had cranial nerve deficits. None of the patients were candidates for brachytherapy because of tumor extent or poor geometry. The tumor histology was squamous cell carcinoma in 10 patients and lymphoepithelioma in one patient. Ten of the 11 patients had received chemotherapy prior to re-irradiation. The heavy charged particle tumor dose delivered ranged from 31.80 GyE to 62.30 GyE (average 50.25 GyE, median 50 GyE). Local control was achieved in 45%. Median survival was 42 months. Actuarial survival was 59% at 3 years and 31% at 5 years (Kaplan-Meier). There were no fatal complications. The results in treating locally advanced recurrent nasopharyngeal carcinoma with heavy charged particles appear superior to those reported by others using photon therapy.

Carcinoma, Squamous Cell

Preliminary results in heavy charged particle irradiation of bone sarcoma.

Between 1979 and 1989, 17 patients with unfavorable bone sarcoma were treated wholly or in part with heavy charged particle irradiation (helium and/or neon ions) at the University of California Lawrence Berkeley Laboratory. The majority of tumors were located near critical structures such as the spinal cord or brain. Gross tumor was present in all but two patients at the time of irradiation. Six patients were treated for recurrent disease. Histologies included osteosarcoma, Ewing's sarcoma, and recurrent osteoblastoma. Four of the osteosarcomata were believed to have been induced by previous therapeutic irradiation for various tumors. Follow-up time since initiation of radiation ranged from 7 to 118 months (median 40 months). The 5-year Kaplan-Maier local control rate was 48%; the corresponding survival rate was 41%. Over half the patients succumbed to distant metastases despite the majority of patients receiving chemotherapy. In this preliminary study, we have shown that heavy charged particle irradiation can be effectively used for control of bone sarcoma. A Phase II trial is warranted to determine optimal treatment for unresectable or gross residual disease.

Antineoplastic Combined Chemotherapy Protocols

Field size dependence of wedge factors.

The radiation output in the presence of wedge filters is characterized by the wedge transmission factor and open beam field size factors. Conventionally, the wedge factor for high-energy photons is measured in a water phantom at depth of maximum dose for a reference field size. Experimental measurements on different wedges indicate that the wedge factors are a function of field size. An analysis of these data show that this is primarily caused by the change in scattered radiation from the treatment head in the presence of wedge filters. The change in phantom scatter and radiation backscattered to the monitor chamber are minimal. For 4- or 6-MV x rays with a 60 degrees wedge, the use of a single wedge factor measured for 10 cm X 10 cm field introduces errors of up to 3.5%, for a 16-cm-wide field. For a 20-cm-wide field with this wedge, the error is 7%. Thinner wedges exhibit less differences.

Humans

Optimization of parameters for fitting linear accelerator photon beams using a modified CBEAM model.

Measured beam profiles and central-axis depth-dose data for 6- and 25-MV photon beams are used to generate a dose matrix which represents the full beam. A corresponding dose matrix is also calculated using the modified CBEAM model. The calculational model uses the usual set of three parameters to define the intensity at beam edges and the parameter that accounts for collimator transmission. An additional set of three parameters is used for the primary profile factor, expressed as a function of distance from the central axis. An optimization program has been adapted to automatically adjust these parameters to minimize the chi 2 between the measured and calculated data. The average values of the parameters for small (6 X 6 cm2), medium (10 X 10 cm2), and large (20 X 20 cm2) field sizes are found to represent the beam adequately for all field sizes. The calculated and the measured doses at any point agree to within 2% for any field size in the range 4 X 4 to 40 X 40 cm2.

Humans

Characteristics of photon beams from Philips SL25 linear accelerators.

The Philips SL25 accelerator is a multimodality machine offering asymmetric collimator jaws and a new type of beam bending and transport system. It produces photon beams, nominally at 6 and 25 MV, and a scattered electron beam with nine selectable energies between 4 and 22 MeV. Dosimetric characteristics for the 6- and 25-MV photon beams are presented with respect to field flatness, surface and depth dose characteristics, isodose distribution, field size factors for both open and wedged fields, and narrow beam transmission data in different materials.

Humans

The effect of patient motion on dose uncertainty in charged particle irradiation for lesions encircling the brain stem or spinal cord.

A specialized charged-particle radiotherapy technique developed at Lawrence Berkeley Laboratory (LBL) is applied to patients with lesions abutting or surrounding the spinal cord or brain stem. This technique divides the target into two parts, one partially surrounding the critical structure (brain stem or spinal cord) and a second excluding the critical structure and abutting the first portion of the target. Compensators are used to conform the dose distribution to the distal surface of the target. This technique represents a novel approach in treating unresectable or residual tumors surrounding the spinal cord or brain stem. Since the placement of the patient with respect to beam-shaping devices is critical for divided-target treatments, a method for calculating dose distributions reflecting random patient motion is proposed, and the effects of random patient motion are studied for two divided-target patient examples. Dose-volume histograms and a normal-tissue complication probability model are used in this analysis. For the patients considered in this study, the normal-tissue-complication probability model predicts that random patient motion less than or equal to 0.2 cm is tolerable in terms of spinal cord complications.

Central Nervous System Neoplasms

Evaluation of fixed- versus variable-modulation treatment modes for charged-particle irradiation of the gastrointestinal tract.

The clinical usefulness of variable-modulation dose delivery of neon ion and proton beams over fixed-modulation beams is evaluated for several patients with tumors in the gastrointestinal tract by comparing dose distributions, dose volume histograms, and predictions of normal tissue complication probabilities calculated with the two methods. Both techniques provide excellent coverage of the target volume with neon ion and proton beams. The advantage of variable modulation is that less dose is delivered proximal to the target volume. For tumors in the gastrointestinal tract, this implies that less dose is given to the liver, gut, kidneys, and lungs. For the ten patients considered in this study, variable-modulation reduced the total integral dose by an average of 17% for neon ion beams and by 18% for protons as compared to fixed-modulation. If the tumor volume is excluded, the reduction in the integral dose to normal tissues ranged from 15% to 32% for neon ions and from 18% to 34% for proton beams. These gains are larger than those anticipated on the basis of an analytic study by Goitein and Chen [Med. Phys. 10, 831-840 (1983)], which predicted integral dose reductions of the order of 10% for protons and 14% for neon ions. They are also larger than those reported in a similar study by Urie and Goitein [Med. Phys. 16, 593-601 (1989)] for proton irradiation of skull-base tumors. This is probably because the tumors in the GI tract considered in this study were more irregularly shaped than Goitein and Chen's analytic model assumes. The results of this study also suggest that due to increased sparing of normal tissues, the number of different portal directions required to achieve a satisfactory treatment plan will be reduced for variable-modulation beam delivery systems. This implies that variable-modulation treatment plans will be easier to execute than current fixed-modulation plans.

Adenocarcinoma