Electrochemotherapy of Mycosis fungoides by interferon-alpha.

Eight patients with 29 lesions of histologically verified 1st stage of Mycosis fungoides were successfully treated by electrochemotherapy with interferon-alpha. For this purpose 8 biphasic pulses were used, each of 50+50 micros duration with 900 micros interpulse intervals, resulting in a burst of 7.1 ms total duration. Compared to the traditional monoimmunotherapy with interferon-alpha applied three times weekly for a total of 4 weeks, the electrochemotherapy was very efficient. Complete response (CR) was observed in 25 (86%) of the 29 treated lesions by single-act electrochemotherapy with interferon-alpha. At the end of the 12-month period, all 29 lesions showed 100% complete response (CR). New lesions for a period of 12 months were not observed. The expected mechanism involved in multiple cytotoxic action of interferon-alpha could be the local increased concentration in the tumour and prolongation of the time of its action after the application of pulses.

Angiogenesis Inhibitors↗

[Electrical stimulation for rapid assessment of extremity tissues vitality in critical ischemia].

INTRODUCTION: In cases of trauma of the extremities, the development of critical tissue ischemia is a frequent complication, requiring surgical intervention with possible amputation. The exact duration of blood supply loss is often difficult to evaluate. Therefore, an easily applicable simple and rapid method for tissues vitality assessment would be of appreciable importance. It could also be used during surgery for delimitation of viable from non-viable tissue. METHOD: The well-known approach for nerve-muscle excitability assessment by electrical stimulation is adopted. Its simplest form is by visual observation of the tissue reaction to the respective excitation. A battery supplied electrical stimulator is built for this purpose, housed in two hand-held electrode holders. The stimuli parameters were selected for efficient excitation of denervated and partially denervated tissue structures. RESULTS: The stimulator was used in assessment of the condition of 23 patients: 16 with severe critical arterial ischemia from arterial occlusive disease and seven with vessel trauma and injuries. Eight extremities were tested immediately after amputation. CONCLUSION: The stimulator was shown to be very efficient for tissue vitality assessment in the diagnostic stage. The easiness of use makes it convenient for application in the ambulatory, during transportation, at the patient bedside, as well as during surgery. It can also be efficient in mass accidents, disasters, or in armed conflicts.

Acute Disease↗

Two-electrode biopotential amplifier with current-driven inputs.

A circuit was developed for a differential two-electrode biopotential amplifier. Current sources at the amplifier inputs were controlled by the common-mode voltage. This principle is well known in telephony for interfacing the telephone line with analogue-type phones. A low impedance of about 1 k(ohm) was obtained between each input and the common point of the circuit. The differential input impedance of 60 M(ohm) was obtained with the use of precision resistors. Considerable reduction in the common-mode voltages of more than 200 times resulted. The circuit can be useful for biosignal acquisition from subjects in areas of very high electromagnetic fields, where high common-mode voltages could saturate the input amplifier stages.

Amplifiers, Electronic↗

Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms.

The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low amplitude high frequency current) of the impedance were considered a solution for selection of adequate shock voltages or for current-based defibrillation dosage. A recent approach, called 'impedance-compensating defibrillation' was implemented, where the pulse duration was controlled with respect to the impedance measured during the initial phase of the shock. These considerations raised our interest in reassessment of the transthoracic impedance characteristics and the corresponding measurement methods. The purpose of this work is to study the variations of the transthoracic impedance by a continuous measurement technique during the defibrillation shock and comparing the data with results obtained by modelling. Voltage and current impulse waveforms were acquired during cardioversion of patients with atrial fibrillation or flutter. The same type of defibrillation pulse was taken from dogs after induction of fibrillation. The electrodes were located in the anterior position, for both the patients and animals.

Animals↗

Electrical field and current distributions in electrochemotherapy.

Electrochemotherapy is a method for cancer treatment consisting in combining intratumor injection of cytotoxic agent with the application of intensive electrical stimuli. Thus transient cell membranes permeabilization is created, allowing the agent to better exercise its destroying effect. Positive results have been published in the treatment of cutaneous malignant formations and other types of cancer are under consideration. The electrode configurations presently used are based mainly on empirical treatment results. In vivo imaging of stimulation currents was attempted in animal models. A preliminary study revealed that having in view the relatively high voltages and currents, there was a virtually resistive load to the electrical source. Assuming a homogeneous medium, potential and current distributions were modeled and studied. The results could help in selection of specific electrode designs, depending on tumor size and location. An optimization of the voltages and/or currents by different electrode arrays can lead to obtaining desired field distribution.

Algorithms↗

In-house development of test equipment for quality control and training. Case study: a prototype ECG simulator-tester.

The support services for biomedical technology address a variety of technical and administrative issues, concerning the safe and efficient operation of medical equipment over the period of its intended use and the training of hospital personnel in issues concerning safety and quality. Clinical Engineering Departments undertake the responsibility of developing and operating training programs in medical equipment utilisation apart from the traditional role of training and supervising technicians involved in testing, calibration and preventive/corrective maintenance of electromedical equipment. In view of the above, the Institute of Biomedical Technology and the Centre of Biomedical Engineering collaborated for the design and development of a prototype digital ECG and arrhythmia simulator. In the absence of internationally accepted inspection protocols for ECG simulators, the verification phase of the project involved mainly the inspection of the device's conformity to its initial technical specifications. The results demonstrated that this tester. due to simplicity in construction and easiness of use could be a practical, reliable and economical solution for electrocardiograph and ECG monitor testing and waveform recognition training.

Arrhythmias, Cardiac↗

Two-electrode telemetric instrument for infant heart rate and apnea monitoring.

Infants may be at risk of life threatening episodes caused by still unknown factors. The Sudden Infant Death Syndrome (SIDS) is believed to be connected with respiration problems due to immature and developing brain breathing control, and many other factors. Currently heart rate and respiration monitoring is considered of major importance to be applied in the hospital and eventually at hoinc. The objective is accurate detection of bradycardia (heart rate below a selected limit, usually between 80 and 100 beats/min) and apnea (cessation of breathing for more than 20 s). A telemetric instrument was developed for monitoring the heart rate and respiration by extraction of the respiration signal from the electrocardiogram QRS complex peak-to-peak amplitude. It makes use of two electrodes integrated in a transmitter module, thus avoiding use of leads and also reducing artifacts to an acceptable minimum. The receiver station can be a simple detector with apnea and bradycardia alarms, a more complicated recorder or a fully developed signal analyser.

Artifacts↗

Monitoring relative fluid balance alterations in haemodialysis of diabetic patients by electrical impedance.

Measurements of total-body electrical impedance in the frequency range between 200 Hz and 300 kHz were performed on 37 diabetic patients undergoing chronic haemodialysis. Special attention was paid to the instrument design, where a self-balancing differential current source was used, reducing considerably the common-mode voltage at the amplifier input. The patient-instrument interface includes screened leads, separately driven by unity-gain buffers. The measurement error was < 1% for the impedance within the range of 20 to 1000 omega and < 0.3 degree (mean) for the phase angle. Impedance/phase and ultrafiltration measurements were carried out throughout the entire procedure. Total and extracellular water were computed and compared with extracted fluid volumes. The trends of change of the extracellular and intracellular fluid volumes during and immediately after dialysis corresponded to the respective clinical condition of the patients and enabled us to divide them into four groups. This approach is a step toward continuous monitoring and adaptive treatment, tailored to the individual patient needs.

Adult↗

High-pass filtering of the electrogastrogram.

The recording and processing of an electrogastrogram require adequate band-pass filtering, to suppress unwanted artefacts but preserve the original signal waveform. High-pass filtering of various types, of different time constants tau, filter order, analogue and digital implementation, have been used to obtain higher baseline stability and faster signal recovery after strong artefacts. Special attention should be given to possible signal amplitude and phase distortions due to high-pass filtering, which can strongly influence accurate amplitude measurements or studies of signal propagation from multichannel recordings. Synthesised and original signals are used to demonstrate the effect of high-pass filtering. The use of a first-order filter with tau = 5 s is recommended for EGG studies if not especially directed to investigation of bradygastria. In the opposite case, tau = 15 s should be used, and with backward filtering a full restoration of the original signal can be obtained. The same is valid for recording the electrical activity of the colon. Lower time constants (tau = 5 s or less) can be applied to acquire signals from the small intestines. A radical solution is the use of a DC amplifier with controllable subtraction of the DC component.

Electromyography↗

Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation.

The measurement of successive RR intervals, obtained from the electrocardiogram (ECG), is the basis of any subsequent method for the assessment of variations in heart rate, for example using intervalograms, histograms, trend curves, spectral analysis, etc. The accuracy of measurement directly depends on the sampling rate used for the acquisition of the ECG signal. Depending on specific applications, rates down to 128 Hz are not uncommon. This considerably limits the resolution if RR interval data are to be derived. Interpolation is often employed for solving problems of this type. Linear, cubic and spline interpolations, obtained directly from the MATLAB software product, were applied and compared for the purpose of RR interval measurement. The cubic method was found to combine the improvement of resolution (+/-1 ms) at sampling rates successfully down to 100 Hz, with a rapid operating speed. Comparison examples are given with ECG signals acquired with 1000 Hz, 16-bit sampling.

Adult↗

Non-invasive electrogastrography. Part 1: Correlation between the gastric electrical activity in dogs with implanted and cutaneous electrodes.

Experiments were made on dogs with bipolar silver ball-shaped electrodes chronically implanted on the muscle wall of the stomach. The electrical activity of the gastric muscle wall (electrogastromyogram-EGMG) was characterized by slow potential changes during the quiescent period of the migrating myoelectric complex (MMC) and bursts of spike potentials during the activity period of MMC. Cutaneous (surface) electrodes were placed on the abdominal wall. Waves with a rhythm of 4.5-5 cpm were led off by the cutaneous electrodes (electrogastrogram-EGG), simultaneously with the EGMg. The bursts of spike potentials with the slow gastric potentials in the EGMG corresponded to an increase of the amplitude of the waves in the EGG. Good correlation was found between the number and frequency of spike potentials in a group and the wave amplitude in the EGG. EGG recorded on an electrogastrograph designed by us was characterized by low-amplitude waves corresponding to the slow waves during the period of quiescence of MMC and high-amplitude waves corresponding to the bursts of spike potentials during the activity period of MMC. Therefore it is possible to determine the MMC of the stomach by the changes in the amplitude of the waves in the EGG.

Action Potentials↗

Non-invasive electrogastrography. Part 2. Human electrogastrogram.

The electrical activity of human stomach muscle wall-electrogastrogram (EGG), was led off by surface (cutaneous) electrodes placed on the abdominal wall and recorded on an electrogastrograph. A method for complete elimination of the cardiac artefact was elaborated and successfully implemented. It consists of a preliminary elimination of the QRS complex, based on its higher amplitude and slope. The eliminated intervals were replaced by linear segments. A subsequent low-pass filtering allowed to obtain a high quality EGG signal. The electrical activity of the stomach of healthy volunteers was characterized by waves with a frequency of 3.35 +/- 0.09 cpm during the quiescent periods and 2.99 +/- 0.14 cpm during the activity periods of the migrating myoelectrical complex (MMC). Bearing in mind the correlation between the bursts of spike potentials with the slow waves in the dog EGMG and the high-amplitude waves, characterizing the periods of activity in the dog EGG, we can better differentiate the periods of quiescence and activity by the amplitude of the waves. The wave amplitude during periods of quiescence was 81.13 +/- 20.61 microV, significantly different from the wave amplitude during periods of activity being 164.74 +/- 43.34 microV (n = 7). Thus with this method in visual inspection it is possible to identify MMC of the human stomach by the changes in the amplitude of the waves in the EGG.

Action Potentials↗

Possibilities of the non-invasive electrogastrography.

A non-invasive method for recording the electrical activity of the gastric muscle wall is presented. Electrogastrograms (EGG) with cutaneous electrodes on the abdominal wall were recorded using an original electrogastrograph. High-quality records without cardiac artifacts allowed for identification of waves belonging to the quiescent or activity period of the migrating myoelectric complex (MMC). The amplitude of the waves of the activity period of MMC were almost twice higher than that of the waves of the quiescent period. The wave amplitude immediately after feeding increased two times and a half compared to that during fasting. The high-amplitude waves in the activity periods of MMC and after feeding in the electrogastromyograms (EGMG) of dogs corresponded to bursts of spike potentials with slow potentials, i.e. to intense gastric muscle wall contractions. The method could contribute to the diagnosis of gastric motility disturbances in clinical practice.

Action Potentials↗