PubMed Health⌕ Search

Biomedical subjects

I Deisenhofer

Publications and source records attributed to I Deisenhofer.

At least 19 recordsLinked to original sources

Morphological characteristics of P waves during selective pulmonary vein pacing.

OBJECTIVES: We sought to assess the value of 12-lead electrocardiogram (ECG) P-wave morphology to recognize the paced pulmonary vein (PV). BACKGROUND: Prediction of arrhythmogenic PVs producing ectopy or initiating atrial fibrillation (AF) using 12-lead ECG may facilitate curative ablation. METHODS: In 30 patients P-wave configurations were studied during sinus rhythm and during pacing at six sites from the four PVs: top and bottom of each superior PV and both inferior PVs. The P-wave amplitude, duration and morphology were assessed, and predictive accuracies were calculated for the most significant parameters. An algorithm predicting the paced PV was developed and prospectively evaluated in a different population of 20 patients. RESULTS; Three criteria were used to distinguish right from left PV: 1) a positive P-wave in lead aVL and the amplitude of P-wave in lead I > or =50 microV indicated right PV origin (specificity 100% and 97%, respectively); 2) a notched P-wave in lead II was a predictor of left PV origin (specificity 95%); and 3) the amplitude ratio of lead III/II and the duration of positivity in lead V(1) were also helpful in distinguishing left versus right PV origin. In addition, superior PVs could be distinguished from inferior according to the amplitude in lead II (> or =100 microV). In prospective evaluation, an algorithm based on the above four criteria identified 93% of left versus right PV and totally 79% of the specific PVs paced. CONCLUSIONS: Pacing from the different PVs produced a P-wave with distinctive characteristics that could be used as criteria in an algorithm to identify the PV of origin with an accuracy of 79%.

Aged↗

Noncontact mapping-guided ablation of atrial flutter and enhanced-density mapping of the inferior vena caval-tricuspid annulus isthmus.

Three-dimensional visualization of cardiac activation has become important in providing further insights into pathophysiological mechanisms of arrhythmias and to increase the efficacy of catheter ablation. The noncontact mapping enables a single beat analysis in a reconstructed geometry of the cardiac chamber. The aim of the study was to describe three-dimensional activation patterns and inferior vena caval-tricuspid annulus (IVC-TA) isthmus conduction characteristics in patients with atrial flutter and the noncontact guidance of the radiofrequency ablation of this arrhythmia. In 34 patients with atrial flutter, the noncontact probe was deployed in the RA. The global three-dimensional activation and the isthmus conduction (enhanced density mapping) were delineated during ongoing a trial flutter and paced rhythms. Ablation was performed nonfluoroscopically based on reconstructed anatomy and conduction patterns. Noncontact mapping was compared and validated with conventional multielectrode technique. IVC-TA isthmus ablation was completed successfully in 33 (97%) of 34 patients. In one patient a lower loop reentry around the inferior vena cava was depicted as a mechanism of atrial flutter. In another patient with positive flutter waves in inferior leads, an activation pattern typical of counterclockwise flutter was demonstrated in propagation maps. During a follow-up of 15.9 +/- 5.9 months, two atrial flutter recurrences occurred (5.8%). A gap of the resumed conduction through the IVC-TA isthmus was delineated as a mechanism of recurrence and ablated with one and three radiofrequency applications. Noncontact mapping allows construction of the global activation patterns in typical and atypical atrial flutter. It enables the nonfluoroscopic guidance of atrial flutter ablation and a comprehensive evaluation of the ablation results.

Atrial Flutter↗

Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study.

INTRODUCTION: Supraventricular tachyarrhythmias are the main cause of inappropriate therapies in patients with conventional single chamber implantable cardioverter defibrillators (VVI-ICD). It was anticipated that dual chamber cardioverter defibrillators (DDD-ICD), with their capacity to analyze atrial and ventricular rhythm, could substantially reduce inappropriate therapies. METHODS AND RESULTS: Our prospective study included 92 patients (87 men; mean age 61 +/- 12.7 years) who were randomly assigned to a VVI-ICD (45 patients) or a DDD-ICD (47 patients). Both groups were followed for 7.5 +/- 3.5 and 7.6 +/- 4.1 months, respectively. During the follow-up period, overall 725 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes were recorded in 45 (49%) of 92 patients. Of these episodes, 404 (56%) occurred in the VVI-ICD group and 321 (44%) episodes occurred in the DDD-ICD group. Twenty-three (51%) patients in the VVI-ICD group and 22 (47%) patients in the DDD-ICD group (P = 0.8) developed VT/VF. Overall, 73 (10%) of 725 treated episodes were inappropriate in 6 (13%) patients in the VVI group and in 10 (21%) patients in the DDD-ICD group (P = 0.2). There were 22 (31%) inappropriately treated episodes in the VVI-ICD group and 51 (69%) in the DDD-ICD group. Thirty-two of the 51 inappropriate episodes in the DDD-ICD patients resulted from intermittent atrial sensing problems that led to failure of the respective dual chamber algorithms. Nonfatal complications occurred in 6 (13%) patients in the VVI-ICD group and in 3 (6%) patients in the DDD-ICD group (P = 0.7). CONCLUSION: We conclude that the implanted DDD-ICD and conventional VVI-ICD are equally safe and effective for therapy of life-threatening ventricular tachyarrhythmias. Although DDD-ICDs allow better rhythm classification, the applied detection algorithms do not offer benefits in avoiding inappropriate therapies during supraventricular tachyarrhythmias.

Aged↗

Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation.

BACKGROUND: Radiofrequency catheter ablation of accessory pathways (APs) is very effective in all but a minority of patients. We examined the usefulness and safety of irrigated-tip catheters in treating patients with APs resistant to conventional catheter ablation. METHODS AND RESULTS: Among 314 APs in 301 consecutive patients, conventional ablation failed to eliminate AP conduction in 18 APs in 18 patients (5.7%), 6 of which were located in the left free wall, 5 in the middle/posterior-septal space, and 7 inside the coronary sinus (CS) or its tributaries. Irrigated-tip catheter ablation was subsequently performed with temperature control mode (target temperature, 50 degrees C), a moderate saline flow rate (17 mL/min), and a power limit of 50 W (outside CS) or 20 to 30 W (inside CS) at previously resistant sites. Seventeen of the 18 resistant APs (94%) were successfully ablated with a median of 3 applications using irrigated-tip catheters. A significant increase in power delivery was achieved (20.3+/-11.5 versus 36.5+/-8.2 W; P:<0.01) with irrigated-tip catheters, irrespective of the AP location, particularly inside the CS or its tributaries. No serious complications occurred. CONCLUSIONS: Irrigated-tip catheter ablation is safe and effective in eliminating AP conduction resistant to conventional catheters, irrespective of the location.

Adult↗

Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

BACKGROUND: The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. METHODS AND RESULTS: Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. CONCLUSIONS: Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.

Angiography↗

Mapping-guided ablation of pulmonary veins to cure atrial fibrillation.

Catheter ablation of triggers inducing paroxysms of atrial fibrillation (AF) is an emerging therapy for this common arrhythmia. In a series of 225 consecutive patients with AF resistant to multiple drugs, 96% presented with triggering foci originating from 1 or multiple pulmonary veins (PV), independently of whether or not the patient had ectopy or structural heart disease. The present article describes the mapping and ablation techniques applicable to individual patients: (1) criteria to define an arrhythmogenic PV; (2) use of provocative maneuvers; and (3) the role of circumferential mapping catheters to provide extent, distribution, and activation of PV muscle as well as monitoring distal PV potentials (PVP) during ablation. Radiofrequency ablation can be performed by targeting the PVP during sinus rhythm (right PV) or left atrial pacing (left PV) with the procedural endpoint of PVP elimination, which is more effective in predicting a successful outcome than suppression of acute ectopy. Complete elimination of AF is presently obtained in 70% of patients, allowing interruption of arrhythmias and in use anticoagulants. It is anticipated that continued technologic improvements will improve and facilitate this technique of curative treatment of AF.

Atrial Fibrillation↗

Relationship between surface electrocardiogram characteristics and endocardial activation sequence in patients with typical atrial flutter.

OBJECTIVES: The relationships that exist between endocardial and surface electrocardiogram (ECG) activity in patients with AFl have not been satisfactorily delineated. The aim of the study was to determine the relationships that exist between the atrial endocardial activity and the surface ECG in patients with atrial flutter (AFl). METHODS: In 40 patients with AFl, a 64-electrode basket catheter (BC) was deployed in the right atrium (RA). A decapolar catheter was inserted into the coronary sinus (CS) to record from the left atrium. The temporal relationship between endocardial and surface ECG activity was determined by means of electronic calipers. RESULTS: In counterclockwise AFl, the activation of the lateral wall of RA coincided with the positive deflections in lead I, V1 and V6 and the upstroke component in inferior leads. Plateau duration in lead III (121 +/- 27 ms) correlated strongly with isthmus conduction time (117 +/- 23 ms) (r = 0.91). Septal and left atrial conduction coincided with negative components in lead I, inferior leads and V6 and positive deflections in leads aVL and V1. In clockwise AFl, the F wave was notched in all ECG leads. The first component resulted from the activation of the septum and posterior wall of the RA. The second component was coincident with activity recorded in CS electrograms. The interval between the two deflections (60 +/- 18 ms) correlated strongly with interatrial conduction time (57 +/- 19 ms) (r = 0.84). Interatrial conduction interval was prolonged during AFl as compared to sinus rhythm (60 +/- 18 ms vs 43 +/- 13 ms, p = 0.04). Activation of the lateral wall of RA coincided with the negative components in lead I, inferior leads and V6. CONCLUSIONS: The electrical activity in surface ECG closely correlates with conduction in specific parts of the atria. Polarity of the F wave in an ECG lead is determined by a resultant of opposing activities from the lateral wall of the RA and the left atrium.

Aged↗

Basket catheter-guided three-dimensional activation patterns construction and ablation of common type atrial flutter.

Construction of three-dimensional activation maps and evaluation of ablation-created bidirectional block in the tricuspid valve-inferior vena caval (TV-IVC) isthmus in patients with atrial flutter (AF) are difficult with conventional mapping technique. In 36 patients with type I AF (25 men, 11 women; mean age 62 +/- 10.5 years) a multielectrode basket catheter (BC) was deployed in the right atrium (RA). Out of 64 BC electrodes, 56 bipolar electrograms were derived. Three-dimensional activation patterns were constructed with a software program. Stable electrograms of satisfactory quality were obtained in 49 +/- 2 electrode pairs. Capture was possible in 36 +/- 3 of bipoles. In counterclockwise AF (CCW-AF) and clockwise AF (CW-AF) episodes, cycle lengths and TV-IVC isthmus conduction times were 248 +/- 26 ms and 251 +/- 23 ms, (P = 0.74) and 105 +/- 28 ms and 106 +/- 33 ms (P = 0.92), respectively. Conduction velocity in the TV-IVC isthmus was lower than in the anterior or septal limbs of the circuit, in counterclockwise or clockwise episodes. Double potentials were recorded in 94% of patients. Three-dimensional activation patterns were delineated and displayed as isochronal maps. The reentry circuit involved the TV-IVC isthmus, septal, and anterior walls and a part of the RA roof anterior to superior vena cava. Postablation isthmus conduction was evaluated through the sequence criteria, local electrogram-based criteria, and the analysis of three-dimensional activation patterns of the paced rhythms. The complete isthmus block was associated with a significant increase of the low anterior low septal conduction interval (152 +/- 29 vs 104 +/- 32 ms, P = 0.001) and the low septal-low anterior conduction interval (150 +/- 31 vs 107 +/- 33 ms, P = 0.001). Radiofrequency ablation was successful in 32 (90%) of 36 patients. In conclusion, the current mapping system enables construction of three-dimensional activation patterns and facilitates evaluation of the postablation TV-IVC isthmus block in patients with AF.

Adult↗

Mid-term follow-up of endocardial biventricular pacing.

Biventricular (BV) pacing is a promising treatment of end-stage heart failure. This article describes our experience with a strictly endocardial BV pacing system in patients with severe congestive heart failure. Three women and eight men (age 65 +/- 9 years) with drug-resistant end-stage CHF underwent implantation of an endocardial BV pacing system. In the first seven patients, the left ventricular lead was placed via a combined femoral and internal jugular approach. In the last four patients, the transseptal puncture was directly performed via the right internal jugular vein with a dedicated kit. The procedure was successful in all 11 patients. The acute left ventricular and BV thresholds were 1.3 +/- 0.6 V and 2.4 +/- 1 V, respectively. The QRS duration decreased from 214 +/- 57 to 176 +/- 25 ms. A functional improvement was noted in ten patients with a decrease in mean NYHA functional class from 3.7 +/- 0.5 before, to 2.6 +/- 0.9 after system implantation. A significant decrease in pulmonary capillary wedge pressure and increase in cardiac output were measured in eight patients. During follow-up, four patients died from CHF (n = 3) or ventricular fibrillation (n = 1). Under oral anticoagulation, no thromboembolic event was observed but one transient ischemic attack occurred in one patient whose anticoagulation was interrupted. Endocardial BV pacing is technically feasible and appears safe, though further studies are needed before it is used on a longer scale.

Aged↗

Multiple sources initiating atrial fibrillation from a single pulmonary vein identified by a circumferential catheter.

The pulmonary veins are the predominant source of ectopic activity initiating AF. The reproducibility of intrapulmonary vein activation during ectopic activity and/or initiation of multiple AF episodes was examined. Eighty-nine pulmonary veins (PVs) among 29 patients undergoing radiofrequency ablation of AF were studied with a 15- to 20-mm diameter, circumferential PV catheter equipped with ten electrodes and a deflectable shaft. Local electrograms were recorded simultaneously during sinus rhythm, ectopic activity, or AF onset, spontaneously or induced via the catheter left in a stable position. Fifty-four arrhythmogenic veins were identified, 39 showing isolated ectopy, and 8 displayed repetitive ectopy (in salvos). The earliest site of activation and the sequence of intra-PV activation during isolated ectopy was identical to that observed during consecutive ectopic complexes in 77% and variable in 23% during isolated ectopy. The earliest activity was sometimes limited to a single bipole. During repetitive ectopy and AF initiation, multiple sources and/or variable activation patterns were noted in 53% of instances, indicating the presence of multiple arrhythmogenic foci within the same PV. Simultaneous electrogram recordings with a circumferential PV catheter identified the presence of multiple arrhythmogenic foci within a single PV.

Atrial Fibrillation↗

Concealed left pulmonary vein potentials unmasked by left atrial stimulation.

Pulmonary vein potentials (PVPs), though obvious during ectopic activity, are frequently invisible during sinus rhythm when they need to be distinguished from left atrial (LA) potentials to perform successful ablation procedures. Thirty-six patients with paroxysmal atrial fibrillation underwent circumferential PV mapping with a circular ten-electrode catheter during sinus rhythm, and during pacing from the right atrium, proximal and distal coronary sinus (CS), and LA. Ablation was performed at the ostium of the PV, the procedural endpoint consisting of electrical disconnection of the PV from the LA. A total of 93 PVs (excluding the right inferior PV) were mapped. During sinus rhythm, distinct right PVPs were present in all instances, while they were concealed within the electrograms recorded from the left inferior and superior PV in 23 (64%) patients. Distal CS or LA appendage pacing unmasked and separated left PV from LA potentials by a mean of 19 +/- 14 ms; the LA-to-left-PV potential interval measured 36 +/- 14 ms. The number of deflections also increased from 2.1 +/- 0.7 during sinus rhythm to 3 +/- 1.4 during LA stimulation. However, in the right superior PV, pacing caused overlapping of atrial potentials with right superior PVPs. RF ablation of the left PVPs was performed during distal or LA pacing in 23 patients, while in the right superior PV it was performed during sinus rhythm eliminating all, including unmasked, left PVPs, providing proof of their PV origin. Distal CS or LA pacing is required to recognize left PVPs in approximately 2/3 of patients and facilitates RF ablation.

Atrial Fibrillation↗

Noncontact mapping-guided catheter ablation of atrial fibrillation associated with left atrial ectopy.

We report the use of a novel noncontact mapping system used to perform left atrial mapping and to guide radiofrequency ablation in two patients, each with atrial fibrillation (AF) triggered by left atrial ectopy. A noncontact multielectrode probe and ablation catheter were advanced into the left atrium through a transseptal puncture or a patent foramen ovale. Isopotential mapping delineated the focal origin at the ostium of the right lower pulmonary vein in one patient and close to the ostium of the left upper pulmonary vein in the other patient. The ablation catheter was guided to the target sites using a locator signal. The foci were ablated successfully in both patients. No recurrences of AF were observed during follow-up at 4 and 6 months, respectively.

Atrial Fibrillation↗

ECG changes in a 25-year-old woman with hypocalcemia due to hypoparathyroidism. Hypocalcemia mimicking acute myocardial infarction.

The case of a 25-year-old woman presenting with chest pain, ECG changes, and laboratory findings suggestive of myocardial infarction is reported. Cardiac catheterization showed impaired left ventricular performance but otherwise normal coronary arteries. Laboratory analyses revealed primary hypoparathyroidism, and supplementation with calcium and vitamin D(3) was initiated. There was subsequent improvement in laboratory findings as well as echocardiographically determined left ventricular performance. Thereafter, the patient remained asymptomatic. Apart from some persisting ECG repolarization disturbances, there was complete normalization of the initial changes. This case demonstrates a combination of clinical, blood biochemical, and ECG findings mimicking acute myocardial infarction.

Adult↗

Electrophysiologically guided ablation of the pulmonary veins for the curative treatment of atrial fibrillation.

Catheter ablation of triggers that induce paroxysms of atrial fibrillation (AF) is an emerging curative therapy for this most common of supraventricular arrhythmias. In a series of 225 consecutive patients with multidrug resistant AF, 96% of triggering foci originated from one or several pulmonary veins (PV) independent of ambient ectopy or structural heart disease. This article describes an ablation procedure that is guided by activation mapping tailored to each individual PV, including criteria to define an arrhythmogenic PV, the use of provocative manoeuvres, the role of circumferential mapping catheters to provide information on the extent, distribution and activation of PV muscle as well as the monitoring of distal PV potentials (PVP) during ablation. Radiofrequency ablation to eliminate distal PVPs is performed by targeting the proximal PVP during sinus rhythm (right PV) or left atrial pacing (left PV). This end-point predicts a successful outcome more often than acute ectopy suppression. Complete elimination of AF is presently achieved in 70% of the patients, resulting in the elimination of antiarrhythmic treatment and suspension of anticoagulant treatment. It is anticipated that continued technological development will improve and facilitate this technique of curative treatment of AF.

Atrial Fibrillation↗

Recurrent symptomatic bilateral bundle branch block in a 74-year-old patient with a prosthetic aortic valve: a description of a case and review of the literature.

This report concerns a 74-year-old patient who had undergone aortic valve replacement 11 years earlier. On admission, the patient complained of shortness of breath when climbing two flights of stairs; there was no history of dizziness, fainting or sensations of arrhythmias. An ECG at rest showed first-degree atrioventricular (A-V) block together with left bundle branch block (LBBB). On bicycle ergometry, there was a fall in blood pressure and in heart rate due to a second-degree (2:1) A-V block along with the LBBB. After termination of exercise, the PR interval increased further from 0.24 s to >0.3 s, together with right bundle branch block (RBBB) and 1:1 A-V conduction instead of LBBB. Finally, at a constant atrial rate of 98/min, the RBBB disappeared, LBBB recurred, again with 2:1 A-V conduction. The diagnosis was bilateral BBB together with first degree A-V block at rest and higher-degree A-V block on effort. The patient underwent pacemaker implantation and was discharged shortly thereafter free of symptoms.

Aged↗

Clinical experience with a novel multielectrode basket catheter in right atrial tachycardias.

BACKGROUND: The complexity of atrial tachycardias (ATs) makes the electroanatomic characterization of the arrhythmogenic substrate difficult with conventional mapping techniques. The aim of our study was to evaluate possible advantages of a novel multielectrode basket catheter (MBC) in patients with AT. METHODS AND RESULTS: In 31 patients with AT, an MBC composed of 64 electrodes was deployed in the right atrium (RA). The possibility of deployment, spatial relations between MBC and RA, MBC recording and pacing capabilities, mapping performance, and MBC-guided ablation were assessed. MBC deployment was possible in all 31 patients. The MBC was left in the RA for 175+/-44 minutes. Stable bipolar electrograms were recorded in 88+/-4% of electrodes. Pacing from bipoles was possible in 64+/-5% of electrode pairs. The earliest activity intervals, in relation to P-wave onset, measured from the MBC and standard roving catheters were 41+/-9 and 46+/-6 ms, respectively (P=0.21). Radiofrequency ablation was successful in 15 (94%) of 16 patients in whom it was attempted, including 2 patients with polymorphic right atrial tachycardia (RAT), 2 with RAT-atrial flutter combination, 1 with macroreentrant AT, and 1 with focal origin of atrial fibrillation. CONCLUSIONS: These data demonstrate that MBC can be used safely in patients with right atrial arrhythmias. The simultaneous multielectrode mapping aids in the rapid identification of sites of origin of the AT and facilitates radiofrequency ablation procedures. The technique is especially effective for complex atrial arrhythmias.

Adult↗