Snoring noise pollution--the need for objective quantification of annoyance, regulatory guidelines and mandatory therapy for snoring.

Habitual snoring without episodes of apnea or hypoventilation and without respiratory related arousals is considered to be annoying and without any need for treatment. However, studies seem to suggest an enormous psychosocial impact of annoyance for the bed partner. Apart from subjective questionnaires there still exists no generally accepted mode of measurement that can describe snoring objectively. We therefore adapted methods developed for environmental medicine and established a new snore score using psycho-acoustic parameters. For quantification of snoring noise we conducted nocturnal measurements in 19 habitual snorers. Free-field snore sounds were acquired with two low-cost non-contact microphones and transferred to a PC (sampling frequency 11 kHz). The data were recorded, analysed and stored automatically using a MATLAB script. Following the analysis of sound characteristics and levels, the score was computed from relevant parameters containing the rating level (L(R)), maximum level, two percentile levels for frequent maxima (L(5)S; L(1)) and snoring time. The determined values substantially exceeded the prescribed limits defined by WHO noise guidelines, and mainly affected the equivalent continuous sound exposure level, rating level and the immission standard values of brief noise peaks, whose maximum was exceeded by up to 32 dB(A). The Berlin snore score illustrated the objective acoustic annoyance on a scale from 0 to 100. It allows inter-individual comparison and objectifies the need for therapy. The clinical applicability of evaluating the reduction of snoring after surgical therapy is discussed exemplarily. The presented measuring method was found to be suitable for quantifying snoring noise and can be easily integrated into existing polysomnographic applications. In the case of habitual snoring with objective evidence of psychosocially disturbing acoustic annoyance, health fund providers should assume the costs of mandatory medical therapy.

Acoustics↗

Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome.

The current study investigated the night-to-night variability and diagnostic accuracy of the oxygen desaturation index (ODI), as measured by ambulatory monitoring, in the diagnosis of mild and moderate obstructive sleep apnoea-hypopnoea syndrome. To assess the variability of the ODI, 35 patients were monitored at home during 7 consecutive nights by means of a portable recording device, the MESAM-IV. The ODI variability factor and the influence of age, body mass index (BMI), alcohol, and body position were assessed. Furthermore, the diagnostic accuracy of the MESAM-IV was measured by comparison with polysomnographical outcomes in 18 patients. During home recording, the median ODI was 10.9 (interquartile range: 5.8-16.1) across the patients. Although the reliability of the ODI was adequate, the probability of placing the patient in the wrong severity category (ODI < or =15 or ODI >15) when only one single recording was taken is 14.4%. ODI variability was not significantly influenced by age, BMI, time spent in a supine position, or mild dosages of alcohol. A good correlation was found between the apnoea-hypopnoea index and the ODI. In conclusion, the findings suggest that the diagnostic accuracy of the MESAM-IV is strong, since the oxygen desaturation index is correlated with the apnoea-hypopnoea index. In most obstructive sleep apnoea-hypopnoea syndrome patients, oxygen desaturation index variability is rather small, and screening could be reliably based on single 1-night recordings.

Female↗

Spectral oscillations of RR intervals in sleep apnoea/hypopnoea syndrome patients.

A recent study has shown that daytime heart rate variability is reduced in obstructive sleep apnoea/hypopnoea syndrome (OSAHS) patients. In the present study, the hypothesis was that sympathovagal balance around apnoeas/hypopnoeas and nocturnal autonomic activity are altered in OSAHS patients. Frequency- and time-domain analyses of RR intervals were performed to monitor sympathovagal activity noninvasively. Fourteen untreated OSAHS patients and seven healthy subjects underwent overnight polysomnography. Low (LF) and total (TF) frequency power increased 2 min around the end of apnoeas/hypopnoeas (LF 229+/-38 ms2 TF 345+/-45 ms2) compared with undisturbed sleep (LF 106+/-18 ms2, TF 203+/-23 ms2). The increase in high frequency (HF) power was not significant. LF increase was proportionally higher than the HF increase (normalised LF (LFn) 67+/-1 units, normalised HF (HFn) 33+/-1 units) compared with undisturbed sleep (LFn 52+/-2 units, HFn 48+/-2 units). RR duration did not change around apnoeas/hypopnoeas (RR 904+/-28 ms). The LF and TF power increase was greater around arousal-inducing (LF 260+/-45 ms2 TF 390+/-65 ms2) compared with self-terminating (LF 161+/-31 ms2, TF 249+/-40 ms2) apnoeas/hypopnoeas; the LF and LFn increases were significant in both groups compared with undisturbed sleep and HF power differences were nonsignificant. RR intervals were longer around self-terminating apnoeas/hypopnoeas (RR 914+/-29 ms); the differences were not significant compared with undisturbed sleep. RR interval spectral power was not influenced by the event type. RR duration decreased (912+/-28 ms) and LF, HF and TF power increased (LF 111+/-16 ms2 , HF 62+/-6 ms , TF 173+/-21 ms2) across patients, compared with healthy controls (RR 1138+/-91 ms, LF 57+/-3 ms2, HF 35+/-3 ms2, TF 91+/-6 ms2). LFn and HFn did not change significantly. Sympathetic activity increases around apnoeas/hypopnoeas. The recurrent nocturnal fluctuations of sympathovagal balance and the overall increase of nocturnal autonomic activity may be of importance in the development of cardiovascular disease in sleep apnoea patients.

Adult↗

Arousability in sleep apnoea/hypopnoea syndrome patients.

Sleep disruption and daytime sleepiness in obstructive sleep apnoea/hypopnoea syndrome (OSAHS) patients result from recurrent apnoeas/hypopnoeas and arousals from sleep. Around 30% of apnoeas/hypopnoeas are not terminated by visible cortical arousals. The current authors tested the hypotheses that arousal induction is linked to sleep stage, oxygen desaturation, event type, event duration and time of occurrence during the night. Fifteen patients with OSAHS of varying severity were studied and all their apnoeas/hypopnoeas were evaluated. Eight of 15 patients had apnoeas/hypopnoeas in all sleep stages, and all their 610 apnoeas/hypopnoeas were analysed in the between stages comparison; data from all 15 patients were included in other comparisons. Thirty-four per cent of apnoeas/hypopnoeas during slow wave sleep (SWS) were associated with arousal, significantly less than the 77% during nonrapid eye movement (NREM) 1 and 2 and 62% during rapid eye movement (REM) sleep. Arousal induction was not affected by oxygen desaturation, event type, duration or time of the night. The apnoeal/hypopnoea index was 39 x h(-1) in REM 1 and 2, significantly higher compared to 17 x h(-1) in REM or to 11 x h(-1) in SWS sleep. In conclusion, apnoeas/hypopnoeas in slow wave sleep are associated with fewer cortically apparent, visually detected arousals.

Arousal↗

Electroencephalographic spectral analysis: detection of cortical activity changes in sleep apnoea patients.

There are no visible electroencephalographic (EEG) changes at the termination of some apnoeas and hypopnoeas. This study tests the hypothesis that cortical activity fluctuates at apnoea/hypopnoea termination, despite the lack of visible changes. To detect these changes, EEG spectral analysis was performed and centred around the end of apnoeas/hypopnoeas in 15 sleepy patients. Ten second windows were applied and comparisons were conducted between the normalised power of the same frequency bands before and after termination of each apnoea/hypopnoea. Comparisons were performed within patients between apnoeas/hypopnoeas and periods of undisturbed sleep as well as between patients and healthy subjects during sleep. Normalised theta power (4-8 Hz) decreased significantly at apnoea/hypopnoea termination. No significant changes were found between consecutive periods of undisturbed sleep across the 15 patients. During nonrapid eye movement sleep, changes were detected irrespective of arousal visibility. During rapid eye movement sleep, nonarousal apnoeas/hypopnoeas were not accompanied by any significant spectral power changes. Theta power was significantly lower across patients compared to healthy subjects (p=0.03) and was correlated to the apnoea/hypopnoea index (rho=0.6, p=0.008). The authors conclude that electroencephalographic spectral analysis improves detection of changes at apnoea/hypopnoea termination. Further validation is needed to determine whether it improves correlation between nocturnal measures and daytime symptoms.

Arousal↗

Quantification of the effect of inhaled budesonide on airway inflammation in intermittent asthma by bronchitis index.

The bronchitis index (BI) is a scoring system for the visual quantification of airway inflammation by flexible bronchoscopy. A prospective study was carried out to determine whether patients with intermittent asthma present a considerable visible airway inflammation. Ten steroid-naive patients with intermittent asthma taking only inhaled beta2-agonists were enrolled and received budesonide (800 microg/day) over a period of 4 weeks. The airway inflammation was assessed by flexible electronic videobronchoscopy before and after the steroid treatment phase and quantified using the BI. Despite normal pulmonary function, all patients with intermittent asthma showed a marked visible airway inflammation that was reversed by a 4-week treatment with the inhaled steroid budesonide. The present study demonstrates that the BI may be useful as a clinical research tool for the assessment and quantification of airway inflammation in asthma. Furthermore, our results support the widely recognized theory that airway inflammation is present even in patients with mild asthma, and emphasize the necessity of an early therapy with inhaled steroids.

Administration, Inhalation↗

Value of bronchial artery embolisation with platinum coils in tumorous pulmonary bleeding.

We performed bronchial artery embolizations (BAE) using platinum coils with Dacron fibres in 30 consecutive patients with haemoptysis due to bronchial carcinoma. The aim of the study was to compare immediate results of bleeding cessation, recurrence and survival rates with a historical control group of 15 patients with tumorous pulmonary bleeding who were treated conservatively (non-BAE-group). Bronchial artery embolisation with platinum coils stopped active bleeding in all patients immediately. Comparing the BAE group and controls the cessation of first time haemoptysis (BAE 100% versus non-BAE 93%) and the rates of bleeding recurrence (BAE 50% versus non-BAE 47%) were similar in either group. In case of recurrent bleeding, repeated BAE led to a definite cessation of pulmonary haemorrhage in every case. In contrast, all patients with recurrent haemoptysis without a repeated BAE (8 patients, 27%) and all patients with bleeding recurrence in the non-BAE group died from pulmonary haemorrhage (8 patients, 53%). The mean survival time of the BAE group was significantly longer compared with the non-BAE group, 139 (range: 1-818) days versus 62 (range: 1-186) days (P<0.05). We conclude that consistent BAE proved beneficial in tumorous pulmonary bleeding, particularly with regard to the permanent arrest of haemorrhage in case of recurrence.

Aged↗

Critical evaluation of the effect of valerian extract on sleep structure and sleep quality.

A carefully designed study assessed the short-term (single dose) and long-term (14 days with multiple dosage) effects of a valerian extract on both objective and subjective sleep parameters. The investigation was performed as a randomised, double-blind, placebo-controlled, cross-over study. Sixteen patients (4 male, 12 female) with previously established psychophysiological insomnia (ICSD-code 1.A.1.), and with a median age of 49 (range: 22 to 55), were included in the study. The main inclusion criteria were reported primary insomnia according to ICSD criteria, which was confirmed by polysomnographic recording, and the absence of acute diseases. During the study, the patients underwent 8 polysomnographic recordings: i.e., 2 recordings (baseline and study night) at each time point at which the short and long-term effects of placebo and valerian were tested. The target variable of the study was sleep efficiency. Other parameters describing objective sleep structure were the usual features of sleep-stage analysis, based on the rules of Rechtschaffen and Kales (1968), and the arousal index (scored according to ASDA criteria, 1992) as a sleep microstructure parameter. Subjective parameters such as sleep quality, morning feeling, daytime performance, subjectively perceived duration of sleep latency, and sleep period time were assessed by means of questionnaires. After a single dose of valerian, no effects on sleep structure and subjective sleep assessment were observed. After multiple-dose treatment, sleep efficiency showed a significant increase for both the placebo and the valerian condition in comparison with baseline polysomnography. We confirmed significant differences between valerian and placebo for parameters describing slow-wave sleep. In comparison with the placebo, slow-wave sleep latency was reduced after administration of valerian (21.3 vs. 13.5 min respectively, p<0.05). The SWS percentage of time in bed (TIB) was increased after long-term valerian treatment, in comparison to baseline (9.8 vs. 8.1% respectively, p<0.05). At the same time point, a tendency for shorter subjective sleep latency, as well as a higher correlation coefficient between subjective and objective sleep latencies, were observed under valerian treatment. Other improvements in sleep structure - such as an increase in REM percentage and a decrease in NREM1 percentage - took place simultaneously under placebo and valerian treatment. A remarkable finding of the study was the extremely low number of adverse events during the valerian treatment periods (3 vs. 18 in the placebo period). In conclusion, treatment with a herbal extract of radix valerianae demonstrated positive effects on sleep structure and sleep perception of insomnia patients, and can therefore be recommended for the treatment of patients with mild psychophysiological insomnia.

Adult↗

Sleep apnea syndrome in patients with cardiac pacemaker.

BACKGROUND: Heart rhythm disturbances are cardiac side effects in patients with sleep-disordered breathing (SDB), which in itself is considered to be a risk factor for bradycardic rhythm disturbances. OBJECTIVE: We analyzed the prevalence and degree of SDB in patients who received a cardiac pacemaker due to bradycardic rhythm disturbances and investigated the relationship between the severity of an underlying SDB and the type of heart rhythm disturbance. METHODS AND RESULTS: 192 patients (100 males, 92 females, mean age 62.2 +/-12.2 years) were studied using the portable screening device MESAM IV. The respiratory disturbance index (RDI) was calculated visually. The mean RDI in all patients was 9.13+/-11. 09/h, 11.7+/-13.15/h in males and 6.33+/-7.42/h in females. The prevalence ratio of SDB between men and women was 1.7:1, with significant differences in the respective severity (p<0.05). The screening showed a prevalence of SDB (RDI >10/h) of 32.3%. The highest prevalence was found in the group of patients with atrial fibrillation and bradycardia. However, there were no significant differences compared to other types of rhythm disturbances. The RDI in the population studied depended on age and body mass index, but not on the existence or type of rhythm disturbance and not on concomitant diseases. CONCLUSION: The prevalence of SDB in cardiac pacemaker patients is similar to that in patients of comparable age without a pacemaker. A heart rhythm disturbance does not seem to be an independent risk factor for development of SDB. Nevertheless, the differential diagnosis of bradycardic rhythm disturbances in this age group should include a screening for sleep apnea.

Age Distribution↗

Respiratory arousals in mild obstructive sleep apnea syndrome.

The objective of the study is to identify patients with mild sleep apnea by counting not only apneas and hypopneas, but also mild respiratory events, which do not fulfill apnea or hypopnea criteria, but result in an arousal (Type-R arousal). Arousals related to body movements (Type-M arousal) were separately counted. The influence of nasal continuous positive airway pressure (nCPAP) on respiratory and movement arousals was analyzed. Daytime sleepiness before and after nCPAP and its relationship to arousal types was investigated using the Multiple Sleep Latency Test (MSLT) and a standardised questionnaire. Twenty-two patients with a mean age of 43.6 +/- 9.2 years underwent polysomnographic evaluation on a baseline night, and during three nights with nCPAP. On the baseline night, subjects presented with a mean RDI of 10.5 +/- 7.2/h, an apnea index (AI) of 1.2 +/- 1.5/h, a hypopnea index (HI) of 9.3 +/- 6.6/h, a R index of 5.2 +/- 5.9/h, and a M index of 9.7 +/- 5.6/h. Use of nCPAP lowered the RDI (p < 0.001) and the R index (p < 0.01). Mean sleep latency in the MSLT increased with nCPAP (p < 0.05) and the patient's subjective well being improved (p < 0.01). Correlation analysis revealed a relationship between Type-R arousals and RDI and HI (r = 0.5, p < 0.01) as well as between questionnaire scores and mean sleep latency. The decrease of Type-R indicates the positive effect of nCPAP. Arousal analysis and detection of mild respiratory events associated with arousals are helpful in investigating the sleep structure and in objectifying clinical symptoms and treatment success in patients with mild OSAS.

Adult↗

A new bronchoscopic method to measure airway size.

Bronchoscopic evaluation of stenosis is limited due to radial distortion of bronchoscopic images and the unknown distance between the endoscope and the stenotic area. The purpose of this study was the development and validation of a method for measuring cross-sectional areas in large airways. Distance measurements were performed using a laser probe inserted into the working channel of a bronchoscope. The laser probe was positioned to the locus of interest in the airway, a ring of light (helium/neon) projected on to the luminal wall and the images acquired using an electronic bronchoscope. The images taken were distortion-corrected by means of a computer program. The method was validated by simulating airways using tubes of known diameter. Additionally, distortion-corrected bronchoscopic images were compared with distortion-free videoscopic image analysis of tracheal slices taken from pigs. In the case of the plastic tubes, Pearson's correlation coefficient (r) as well as the intraclass correlation coefficient (ICC) were slightly higher (r=0.99, p<0.01, ICC=0.97) than the correlation of cross-sectional areas between bronchoscopic and videoscopic images of tracheal slices (r=0.88, p<0.01, ICC=0.87). This concept allows accurate and reproducible determination of cross-sectional areas in large airways.

Animals↗

Plasmacytoid monocytes appear in the bronchoalveolar lavage: differences between smokers and nonsmokers.

The primary purpose of this study was to describe the expression pattern of the surface antigens CD68, CD36, 27E10, G16/1, and RM3/1 on bronchoalveolar lavage (BAL) cells of smokers and nonsmokers. We found a cell type, morphologically similar to lymphocytes, which showed a strong expression of the monocyte markers CD68 and CD36. We therefore recognized these cells as plasmacytoid monocytes (PM). Hereby we report the appearance of PM in the BAL and its dependency of smoking. The study was conducted in 40 patients with various lung diseases and normal subjects. Sixteen patients and normal subjects were smokers and 24 were nonsmokers. There was a significant increase of PM in the BAL of smokers compared to nonsmokers. However we could not find a disease-related increase of PM in the BAL. This is the first report demonstrating the occurrence of PM in the BAL. Our data support the monocytic origin of PM and suggest an involvement in T cell-mediated responses of the lung.

Antibody Specificity↗

Pulmonary involvement in diffuse cutaneous systemic sclerosis: broncheoalveolar fluid granulocytosis predicts progression of fibrosing alveolitis.

OBJECTIVE: The clinical course of fibrosing alveolitis (FA) in patients with systemic sclerosis (SSc) may vary considerably from stable condition for years to continuous fatal progression. This prospective study aimed at identifying the prognostic value of bronchoalveolar lavage fluid (BALF) analysis in FASSc. METHODS: Seventy three consecutive patients with SSc and clinical signs of pulmonary involvement were enrolled. Every patient underwent clinical examination, lung function tests, computed tomography (CT), gallium scan, echocardiography, and bronchoalveolar lavage (BAL). Forty nine patients, 26 with pathological and 23 with normal BALF findings were prospectively followed up for two years and re-evaluated annually. RESULTS: At baseline, 51 subjects (70%) showed radiological signs of lung fibrosis and/or alveolitis by CT and diffusion capacity for carbon monoxide (DLco) was decreased in 47 patients (64%). Thirty five patients (48%) had pathological BALF findings. BALF differential counts included BALF granulocytosis in 18, BALF lymphocytosis in 12, and a mixed increase of both granulocytes and lymphocytes in five patients. On follow up, a progression of FA with a significant decrease of DLco was only observed in patients with BALF granulocytosis. In contrast, patients with BALF lymphocytosis or normal BALF cell count had stable lung function parameters during the study period. In none of our patients echocardiography showed evidence of pulmonary hypertension. CONCLUSION: BALF granulocytosis predicts progression of FA with deterioration of lung function, which is most sensitively monitored by DLco. Immunosuppressive treatment is recommended in patients with granulocytic FASSc.

Bronchoalveolar Lavage Fluid↗

Circadian reactions to nCPAP treatment.

To determine possible effects of apnea attacks on the spontaneous behavior of the circadian system (body temperature, sleeping behavior, vigilance), 11 patients with obstructive sleep apnea (OSA) were observed before therapy over a 24 h period under a special constant routine (bed-rest study) and again during therapy with nCPAP (nasal continuous positive airway pressure). Clinical indicators (polysomnographical, subjective sleep quality, etc.) indicated successful therapy. During the bed-rest study with nCPAP therapy, the 24 h amplitude of core temperature was found to be greater than the amplitude measured before therapy. Also, therapy decreased sleep disturbances at night and reduced daytime sleeping times. Consequently, the level of subjective vigilance was higher during the daytime during therapy. OSA attacks do not only impair sleep; they disturb the whole circadian system. This may also impair recuperation and sleep. Further research should test whether measurements of the spontaneous circadian system could have additional diagnostic value and whether the stabilization of the circadian system has therapeutic value.

Adult↗

Arousals and sleep stages in patients with obstructive sleep apnoea syndrome: Changes under nCPAP treatment.

Nocturnal arousals are the essential cause of disturbed sleep structure in patients with obstructive sleep apnoea syndrome (OSAS). The aim of this study was to analyse the relationship between sleep stages, respiratory (type-R) and movement (type-M) related EEG arousals. Furthermore, the value of these arousals as a criterion for the efficiency of nCPAP treatment was estimated. We examined 38 male patients aged between 30 and 71 (49.1 +/- 20.9 SD) y. All patients suffered from OSAS. The mean respiratory disturbance index (RDI) was 47.3 +/- 27.8 per h. Polysomnographic monitoring was carried out on 4 subsequent nights: baseline night, 2 nights of nCPAP titration and nCPAP control night. Sleep was visually scored and EEG arousals were classified into type R and M, depending on whether changes of respiration or movement caused the arousal. The RDI, the R index (type-R/h), the M index (type-M/h) and the R and M indices in different sleep stages were calculated. During the baseline night a deficit of slow wave sleep (SWS) and REM sleep was found. Furthermore there were more type-R than type-M arousals registered (17.4 h-1 [3.6-43.6] vs. 5.9 h-1 [1.6-11.8]) (P < 0.01). They occurred during stages NREM 1, NREM 2 and REM (P < 0.01). An SWS sleep rebound and a reduction of the SWS and REM latencies were already found during the first CPAP night. The R index was reduced during the first CPAP night in all sleep stages (P < 0.01) and remained approximately the same in the following 2 nights (3. CPAP night: 1.1 h-1 [0.3-5.0]). Type M arousals occurred more in stages 1 and 2 (P < 0.01), and remained unchanged under nCPAP. We concluded that differentiation of nocturnal arousals may provide more detailed information regarding the influence of breathing disturbances on sleep. Respiratory related, not movement related, arousals may be a useful additional tool in judging the efficiency of OSAS.

Adult↗

Severe prosthetic valve-related endocarditis following dental scaling: a case report.

There is a well-known correlation between surgical dental procedures and the risk of bacterial endocarditis in patients with prosthetic cardiac valves. A 43-year-old patient with prosthetic aortic and mitral valves, which already have been removed twice because of endocarditis, suffered from a prosthetic valve-related endocarditis following dental scaling, which was performed without any antibiotic prophylaxis. Invasive medical procedures in patients with prosthetic heart valves may lead to endocarditis. Antibiotic prophylaxis is recommended even for dental procedures considered to be "harmless," such as dental scaling.

Adult↗

[Multiple sleep latency test in patients with obstructive snoring].

The objective of our study was to examine the effect of the n-CPAP on day tiredness of patients suffering from obstructive snoring. This effect was objectified by means of the Multiple Sleep Latency Test (MSLT). The MSLT was performed with optimal pressure at 8.00, 10.00, 12.00 and 14.00 hrs. subsequent to the control night and the third CPAP night. The latencies of falling asleep and the sleep stages were determined in accordance with the criteria of Rechtschaffen and Kales. The average latency of falling asleep before therapy was: at 8.00 hrs 9.0 +/- 14.2 min, at 14.00 hrs. 7.2 +/- 6.3 min. The following latencies of falling asleep were observed after the third CPAP night: 8.00 hrs. 14.2 +/- 6.3, 10.00 hrs. 13.4 +/- 6.4, 12.00 hrs. 13.7 +/- 6.4 hrs. 13.7 +/- 6.0 min. This means that after the therapy there was a marked tendency to longer latencies at all 4 points of measurement with significant differences at 12.00 and 14.00 hrs. A comparison of the quality of sleep before and after the therapy yielded an increase in deep sleep and a significant increase in REM density during dream sleep. MSLT enabled objectivation of improved sleep quality and of subjective decrease in day tiredness after CPAP therapy in patients with obstructive snoring. The latency in falling asleep increased at all the points of measurement. Nevertheless, interindividual differences are great, compared with the uniform subjective success of CPAP therapy achieved with these patients.

Adult↗

[Complications of nasal CPAP therapy. Consequences for general practice].

BACKGROUND: The prevalence of the obstructive sleep apnea syndrome is about 5% in the entire population. The amount of treatment-indications grows for this particular sleep-related breathing disorder due to the increasing usage of diagnostic screening tests. In most cases, the positive-pressure ventilation, PPV (nCPAP, nBiPAP) is considered as a highly effective form of treatment, in comparison to other treating methods. The residential polysomnographic supervised adjustment of the treatment is optimally applied to most of the patients. Due to the increasing number of the treated patients, the reports about the appearance of short-termed side effects during the adjustment of the PPV become more frequent. PATIENTS AND RESULTS: We report on 9 patients who showed complications during the initial stage of treatment. The most common one, during the nCPAP-therapy, was the increase of central apneas. Because of this complication, a rapid optimization of the respiratory pressure or a change to a nBiPAP-therapy was necessary in 5 of the patients. 2 of the patients showed cardiac arrhythmias, some of which were severe. One patient produced a remarkable central hypoventilation during the initial phase of a nCPAP-therapy. The nBiPAP-titration combined with right-heart-catheter monitoring could demonstrate in another patient a possible cardiac decompensation through an increased ventilatory pressure. CONCLUSION: The risk of a positive-pressure ventilation is higher in patients with accompanying cardiac, pulmonary, neuropsychiatric and/or otorhinolaryngologic disorders. Considering the various predisposing factors of the patients we suggest an intensive apparative monitoring as well as stuff-supervision during the introduction to a respiratory treatment. If complications appear, a rapid improvement of the ventilatory pressure or a change to another respiratory treatment is indicated.

Aged↗