PubMed Health⌕ Search

Biomedical subjects

I Giráldez

Publications and source records attributed to I Giráldez.

8 recordsLinked to original sources

Organotin contamination in the Atlantic Ocean off the Iberian Peninsula in relation to shipping.

Imposex in female snails, a bioindicator of TBT contamination, and the presence of organotins in snails' tissue and sediments were studied at nine sites off the western Iberian Peninsula. The study was part of a European project (acronym HIC-TBT) co-financed by the EU-LIFE programme, intending to investigate and communicate the impact of organotins from ships in marine ecosystems. Snails and sediments were sampled during two cruises in May/June 1999 and in January 2000 in areas of high, intermediate and low-shipping density. Imposex was found in female snails from several sampling sites, some of which had an imposex incidence of 100%. Differences in sensitivity were found between species; hence comparison of imposex levels between locations where different species were collected was not straightforward. Total organotin concentrations in sediments (sum of butyl and phenyltin compounds) ranged from 21 to 185 ng Sn g(-1) with higher values for most sites sampled in the vicinity of shipping lanes. Organotin concentration in snails' tissue ranged from <5 to 196 ng Sn g(-1), which are similar to those found in snails from other offshore areas contaminated by TBT. Overall, these results give further support to the recent ban on the use of organotin based antifouling paints to all ship size.

Animals↗

Determination of polychlorinated biphenyls in biota samples using simultaneous pressurized liquid extraction and purification.

In order to reduce time and cost of analysis, a new pressurised liquid extraction method that automatically and rapidly achieves quantitative and selective (i.e., lipid-free) extraction of polychlorinated biphenyls (PCBs) in biota tissues was optimized. It consists of on-line clean-up by inclusion of sorbents in the extraction cell. The freeze-dried sample is dispersed with Florisil and loaded in the extraction cell containing an extra amount of Florisil. The extraction is performed under mild conditions using 55 ml of a dichloromethane-pentane (15:85) mixture, a temperature of 40 degrees C, a static extraction time of 10 min and two extraction cycles. The Florisil retains coextracted lipids from the matrix, and the extract, after pre-concentration, is clean enough for direct injection into GC-MS and GC-electron-capture detection (ECD). Quantitative recoveries (from 90 to 106%) are obtained for both native and spiked PCB congeners in samples with a high lipidic content (up to 42% dry mass, in spoonbill eggs). The reproducibility of replicate extractions was better than 11% relative standard deviation. Method detection limits were in the ranges of 0.001-0.004 and 0.002-0.07 ng g(-1) dry mass for GC-ECD and GC-MS-MS, respectively. The method was validated using the standard reference material SRM 2974 (a mussel tissue) from the US National Institute of Standards and Technology, compared to Soxhlet and matrix solid-phase dispersion extraction methods, and used to evaluate the contamination by PCBs in bivalves from South of Spain.

Animals↗

Sample treatment in chromatography-based speciation of organometallic pollutants.

Speciation analysis is nowadays performed routinely in many laboratories to control the quality of the environment, food and health. Chemical speciation analyses generally include the study of different oxidation state of elements or individual organometallic compounds. The determination of the different chemical forms of elements is still an analytical challenge, since they are often unstable and concentrations in different matrices of interest are in the microg l(-1) or even in the ng l(-1) range (e.g., estuarine waters) or ng g(-1) in sediments and biological tissues. For this reason, sensitive and selective analytical atomic techniques are being used as available detectors for speciation, generally coupled with chromatography for the time-resolved introduction of analytes into the atomic spectrometer. The complexity of these instrumental couplings has a straightforward consequence on the duration of the analysis, but sample preparation to separate and transfer the chemical species present in the sample into a solution to be accepted readily by a chromatographic column is the more critical step of total analysis, and demands considerable operator skills and time cost. Traditionally, liquid-liquid extraction has been employed for sample treatment with serious disadvantages, such as consumption, disposal and long-term exposure to organic solvent. In addition, they are usually cumbersome and time-consuming. Therefore, the introduction of new reagents such as sodium tetraethylborate for the simultaneous derivatization of several elements has been proposed. Other possibilities are based in the implementation of techniques for efficient and accelerated isolation of species from the sample matrix. This is the case for microwave-assisted extraction, solid-phase extraction and microextraction, supercritical fluid extraction or pressurized liquid extraction, which offer new possibilities in species treatment, and the advantages of a drastic reduction of the extraction time and the embodiment into on-line flow analysis systems. This new generation of treatment techniques constitutes a good choice as fast extraction methods for feasible species-selective analysis of organometallic compounds under the picogram level, that can be used for national regulatory agencies, governmental and industrial quality control laboratories, and consequently, for manufacturers of analytical instrumentation.

Chromatography↗

Column-switching system for selenium speciation by coupling reversed-phase and ion-exchange high-performance liquid chromatography with microwave-assisted digestion-hydride generation-atomic fluorescence spectrometry.

Speciation of selenocysteine (SeCys), selenomethionine (SeMet), selenoethionine (SeET), selenite (Se(IV)) and selenate (Se(VI)) has been accomplished using high-performance liquid chromatography, with the aid of an anion exchange column and a reversed-phase column, both connected through a six-port switching valve. On-line microwave-assisted digestion and hydride generation steps were performed prior to the atomic fluorescence detection. The elution of the seleno amino acids was accomplished in the reversed-phased column using water as mobile phase. Selenite and selenate were separated in the anion exchange column, using gradient elution with an acetate buffer. The separation of the five selenium compounds took place in 15 min. The detection limits obtained ranged between 0.6 and 0.9 microg l(-1). Values of r>0.998 were obtained for linear fit graphs. A commercial available urine sample was analyzed, in which SeCys and Se(IV) were quantified.

Chromatography, High Pressure Liquid↗

Comparison of the feasibility of three extraction procedures for trace metal partitioning in sediments from south-west Spain.

The feasibility of three sequential extraction schemes (a modification of the Tessier procedure, the scheme proposed by Meguellati and the protocol designed by BCR (now called the Standards, Measurements and Testing Programme, M&T) have been compared to study the distribution of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb and Zn in sediment samples. The comparison has been performed by analyzing Certified Reference Material (CRM-601), a test material (S-12) and seven sediments from the Odiel Marshes Natural Park (located at the Atlantic coast of southern Spain). Samples were classified as sandy (with low iron oxide and organic matter contents) and clay-silty (with high iron oxide and organic matter contents) sediments. A higher metal mobility, especially under reducing conditions, was more properly assessed using the modified Tessier scheme compared to both the BCR and Meguellati procedures, these two later presenting comparative results for the reducible and residual phases. Significant Hg losses were found using the BCR procedure but the quantification of the acid phase for Cd, Cr and Ni was more reliable than that obtained with the modified Tessier and Meguellati schemes.

Environmental Monitoring↗

Temporal fluctuations of tributyltin in the bivalve Venerupis decussata at five stations in southwest Spain.

Filter feeding clams, Venerupis decussata, were sampled every 4 months for 8 years at five locations on the southwest Spain coast and analysed for organotins. All the stations showed a significant sinusoidally shaped seasonal evolution pattern for tributyltin (TBT) superimposed upon a linear decreasing tendency. The amplitude and frequency of fluctuations differed among stations and were correlated to the harbour activities. Fluctuations were greatest at stations with the greatest TBT presence. The long-term trend of TBT in clams indicated half-life values of about 7-14 years. During 1993, water and sediment samples were also collected at monthly intervals and analysed. Correlations between TBT bivalve contents and water concentrations were higher than those found between biota and sediments.

Journal Article↗

Stability and storage problems in organotin speciation in environmental samples.

The stability of both tributyltin (TBT) and triphenyltin (TPT) in water, sediment, oysters and cockles was studied over a period of 18 months using several storage conditions. Butyltins were stable in unacidified sea-water stored in polycarbonate bottles in the dark at 4 degrees C for 7 months, but half of the TBT concentration was lost after 540 d. A comparable preservation time was achieved for butyltins stored on C18 cartridges at room temperature. However, phenyltins extracted from sea-water were stable for only 60 d stored on cartridges and even more pronounced losses (about 90% after 540 d) occurred when they were stored in either polycarbonate or Pyrex glass bottles. Losses of organotins were observed in sediments after air drying and pasteurization treatments using a freeze-dried sediment as a comparator, whereas both butyltin and phenyltin species remained stable in sediments stored at -20 degrees C for the 18 months tested, irrespective of the treatment used for stabilization. Air drying followed by pasteurization was shown to be superior to other treatments for the stabilization of organotin compounds in sediments stored at higher temperatures, but 30% of TBT was lost after 540 d at 25 degrees C. Finally, butyltins were stable in both frozen cockles and oysters in the dark over a 7 month period and in freeze-dried samples stored at 4 degrees C for 5 months, but TBT losses of about 70% were observed after 540 d.

Animals↗

Determination of dialkyldiselenides in water by gas chromatography-mass spectrometry using 1-fluoro-2,4-dinitrobenzene as derivatization reagent.

The feasibility of gas chromatography-mass spectrometry for the speciation of traces of dialkyldiselenides in the presence of dialkylselenides and inorganic selenium species is described, and the procedure is applied to environmental samples. The analysis is based on the reaction of dialkyldiselenide species with 1-fluoro-2,4-dinitrobenzene after volatilization of selenium species as alkylselenols using a volatilization and trap device. Parameters affecting the volatilization and derivatization of the selenium compounds are discussed, and the performance of the method is described. The approach reaches detection limits in the order of nanograms (after a preconcentration step) and has been applied to the analysis of dimethyldiselenium and diethyldiselenium in natural waters.

Dinitrofluorobenzene↗