[Activating group work with residents of retirement and nursing homes].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to I Hensel.
Explore the source record for details and available documents.
In order to investigate the acute effects on lung morphology, lung function, hemodynamic and blood coagulation system, elastase (330 units (U) kg-1 h-1) was continuously infused into 16 anesthetized and mechanically ventilated minipigs. Elastase infusion induced a disturbance of blood coagulation leading to hypocoagulability, a pulmonary leukostasis, interstitial edema, a progressive respiratory failure with prompt increase in pulmonary vascular resistance, decrease in systemic vascular resistance, increased venous admixture, and increased dead space ventilation. Agranulocytosis prevented interstitial edema but not disturbances in pulmonary or hemodynamic function or hypocoagulability. The results clearly indicate that elastase may be involved in the pathophysiology of acute lung failure and defects in the blood coagulation system.
Measurements of pulmonary capillary blood flow by a nitrous oxide rebreathing technique (QN2O) were performed in 21 anesthetized and artificially ventilated minipigs with normal lungs and in nine minipigs with thrombin-induced (75-150 U kg-1 h-1) lung pathology. QN2O was calculated with the Hook-Meyer-formula and compared to cardiac output measurements (thermodilution, QT, or direct Fick's principle, QFick). The coefficient of variation in double QN2O measurements was 0.05. If the tidal volume to dead space ration (VD/VT) is normal, the nitrous oxide method works well, but when the efficacy of ventilation worsens, this gas uptake method fails to detect the circulation of the poorly ventilated parts of the lung. The mean ratio QN2O/QFick in pigs with normal lungs (58 measurements) was 1.00 +/- 0.10 (mean +/- s.d.). During thrombin infusion, the mean ratio QN2O/QT was 0.84 +/- 0.17 (n = 49). After corrections for shunt perfusion (Qs), the mean ration QN2O/(QT-Qs) was 0.89 +/- 0.17 (n = 49). QN2O/QT-Qs) decreased with increasing VD/VT. In measurements during thrombin infusion with VD/VT less than 0.33, the mean ratio QN2O/(QT-Qs) was 0.97 +/- 0.11 (n = 21), with a VD/VT between 0.33 and 0.44, the mean ratio QN2O (QT-QS) was 0.90 +/- 0.08 (n = 20), and with a VD/VT greater than or equal to 0.45, this ratio was 0.62 +/- 0.18 (n = 8). In the presence of only moderate functional inhomogeneities, this noninvasive rebreathing method will offer reliable data on pulmonary perfusion.
The potential role of granulocyte proteinases on experimentally induced ARDS was evaluated. In order to investigate the acute effects on lung function, elastase (330 U kg-1h-1) or thrombin (75-150 U kg-1 h-1) was continuously infused into anaesthetized and mechanically ventilated mini pigs. Both elastase as well as thrombin induced a progressive respiratory failure with prompt increase in pulmonary vascular resistance, and decrease of cardiac output, further a pulmonary leukostasis, and a disturbance of blood coagulation leading to hypocoagulability. High proteolytic activity selectively in the lung indicates a possible role of proteinases released from sequestered polymorphonuclear neutrophils. Similar results following elastase infusion were however obtained in leukopenic animals pretreated with a single dose of dimethylmyleran (5 mg kg-1) which depleted the granulocytes totally. These results offer the possibility that elastase itself may cause respiratory failure and lung tissue damage. On the other hand the digestion pattern of phosphorylase kinase by lung tissue homogenates of thrombin- or elastase-infused mini pigs clearly indicates that elastase is only one of several mediators which may cause experimentally induced ARDS even in the absence of granulocytes.
Explore the source record for details and available documents.
A simple method for determination of the functional residual capacity (FRC) during artificial ventilation by inert gas dilution using a rebreathing technique is described. The measurements can be made during various techniques of mechanical ventilation (eg. PEEP, IMV etc.). Myorelaxation is not required. This technique was used to assess the volume of a lung model (actual volume: 3670 ml) with the result of repeated measures being 3686 +/- 29 ml. Duplicate measurements in artificially ventilated pigs showed a coefficient of variation of +/- 3.2%. In artificially ventilated patients FRC was determined both with this technique and with a reference method, giving a difference of 111 +/- 55 ml (p less than 0.001). The errors in measurements of FRC by this method are small, and as the measurement requires a minimum of time and the apparatus is simple, the method is accurate and yet simple enough to be used on a routine basis in the intensive care unit. Even high risk patients are not disturbed by this technique. The method has the advantage that it can easily be learned by nurses and paramedical personal.
Pulmonary diffusing capacity may be determined by rebreathing techniques using various test gases. The errors caused by functional inhomogenities are smaller with the rebreathing method than those found in the single-breath technique. However, until now there have been some disadvantages to the clinical application of the rebreathing technique. In the present paper, a modification of the rebreathing technique suggested by Piiper, Scheid, Meyer and Adaro (1975 and 1976), in which pulmonary diffusing capacity for carbon monoxide, DCO(RB), is measured, has been applied to intubated and anesthetised patients. Measurements were performed in 39 surgical patients with healthy lungs during artificial ventilation and narcosis. Under these conditions all patients had a DCO(RB) greater than or equal to 75 ml/min . kPa (10 ml/min.torr). The coefficient of variation for duplicate measurements was +/- 4.2%. In the same patients DCO-single-breath-measurements, DCO(SB), were also made. There was a significant (p less than 0.0001) correlation between DCO(RB) in artificially ventilated, anaesthetised patients in a supine position and DCO(SB) for spontaneously breathing, awake patients in a sitting position. A linear regression analysis of the data showed the DCO(SB) was related to DCO(RB) in the following manner: DCO(SB) = 1.62DCO(RB) = 4.44 (ml/min.torr) (r = 0.71, n = 39). The mean value of DCO(RB) was 53.4% of the mean value of DCO(SB). This difference may be due to the combination of different techniques used and different conditions during the measurements (reduced FRC, difference in F1O2 etc.). The histogramm of the distribution of DCO(RB) had a similar form to that of DCO(SB). The modified method has a high reproducibility and can easily be performed as a bed-side test without disturbance to patients with an endotracheal tube.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.