PubMed HealthSearch

Biomedical subjects

I Hino

Publications and source records attributed to I Hino.

15 recordsLinked to original sources

[A case of pseudoinfarct of the liver (Zahn's infarct)].

We reported a case of pseudoinfarct (Zahn's infarct) of the liver caused by the inflammatory pseudotumor. A dense segmental staining in the area of Zahn's infarct, which was thought to be characteristic finding, was found on the hepatic angiography. This finding was supposed to be consistent with sinusoidal hyperemia according to the pathological finding.

Adult

[Ultrasonographic diagnosis of mild fatty infiltration of the liver with the difference between liver and kidney echolevels].

At the same dynamic range (DR) a constant difference of echolevels was found between two materials with different acoustic impedance in any gain-setting by the phantom study. Our retrospective study in which we compared the difference between liver-kidney echolevels with the US-findings of fatty liver indicated that the difference over 10 in echoleveled by our equipment with 3.5 MHz phased array sector scan and 42 dB DR had a possibility of the fatty infiltration of the live. In our prospective study of 1452 abdominal US-studies we found 93 cases (6.5%) with the difference over 10 in echolevel. In all these patients the difference of liver-spleen CT-numbers and liver-kidney echolevels was compared. Although the liver CT-number is normally higher than the spleen, 75 of 93 patients showed the lower liver CT-number than that of the spleen, indicating fatty infiltration of the liver. The abnormal difference of echolevels were independent from the severity of fatty infiltration. Concerning the US-findings, "bright liver" (77.4%) and "masking sign" (66.7%) were more sensitive than "vascular blurring" (44.1%) and "deep attenuation" (44.1%). But for the severe fatty infiltration with the difference over -20 H.U. between liver-spleen CT numbers, the last two findings seemed very credible. The abnormal difference between liver-kidney echolevels was most sensitive (80.7%), especially in mild cases with 0 to -19 H.U. (53 in 75 cases), and very objective than the other US-findings.

Fatty Liver

A kinetic study on secretion and elimination of endogenous thyrotropin in the thyrotropin-releasing hormone test.

Serum thyrotropin (TSH) concentrations in normal young men were measured by a high-sensitivity immunoradiometric assay before and after intravenous administration of 500 micrograms of TSH-releasing hormone (TRH). A kinetic model was applied to evaluate the secretion rate both before (V0) and after (V0 + V* at maximum rate) the administration of TRH, the elimination constant (K), the latent time (L) between TRH administration and start of the stimulated secretion, and the total amount of TSH (T) released in response to TRH. V0, V* and T varied widely from individual to individual, but correlated well with TSH before TRH administration (r = 0.93, 0.80 and 0.87, respectively). A few minutes (1.89 +/- 1.30 min) after the administration of TRH, the secretion of TSH (0.025 +/- 0.016 microU/min ml) was stimulated, and the total release over about 1 h was 12.5 +/- 5.6 microU/ml. Serum TSH was maximum at 31.5 +/- 5.7 min. The half-time of disappearance of TSH was 42 +/- 9 min. These data confirm that the stimulated secretion continues for more than 30 min, and that the pituitary releases 43.2 +/- 22.9 mU of TSH (assuming the distribution volume of TSH is 5.8% of body weight) in response to TRH, an amount which correlates closely (r = 0.91) with TSH before TRH administration.

Adult

[Scintigraphic estimation of dearterialization after transcatheter hepatic arterial embolization therapy].

Radionuclide angiography was performed by bolus injection of 99mTc-phytate in 10 patients with liver neoplasms before and after the transcatheter hepatic arterial embolization therapy. The ratio of the slopes of the upstrokes for the hepatic arterial and abdominal aortic first transit curves constitutes the regional hepatic arterial to aortic blood flow ratio (RHA/A ratio), which represents quantitatively the arterial blood flow of hepatic region of interest as a fraction of aortic blood flow. The degree of embolic dearterialization was estimated by the change of this ratio derives from the same region of interest for each patient before and after the embolization. The values and post-embolic reduction of the ratio correlated well individually with the angiographic features and other patients' data. The arterial blood supply to the tumor could not be reducted using Lipiodol alone as the embolic material in only 1 case. The finding that the splenic arterial to aortic blood flow ratio (S/A ratio), calculated in the same way, was practically unchanged after the hepatic arterial embolization indicates the good reproducibility of these measurements. This noninvasive method may be helpful to evaluate the therapeutic effect of hepatic arterial embolization.

Aged

[An evaluation of predicting postoperative residual liver function using 99mTc tin colloid].

The rate of clearance (K value) of 99mTc tin colloid in the liver differentiates normal subjects from liver cirrhosis patients; so 99mTc tin colloid is as useful as 198Au colloid as a marker of liver function. There are several reports concerning volume estimation using liver scintigraphy. Our original method was devised to measure the effective liver volume by scintigraphy. By combining the K value with effective liver volume, a predictive index was obtained in order to predict the residual liver function before hepatic resection. The index in 24 patients with liver diseases was investigated before hepatic resection. Three of them died due to hepatic failure after hepatic resection. The indices were between 0.40 and 0.45 in two of these three patients and 0.338 in one. Among the patients without hepatic failure, the indices showed more than 0.45 in 19 patients and between 0.40 and 0.45 in two. These results indicate that the limitation of hepatic resection is between 0.40 and 0.45 of the predictive index.

Adult

[Evaluation and comparison of high-sensitivity immunoradiometric assay kits for thyroid stimulating hormone].

Fundamental and clinical characteristics of 3 kinds of high-sensitivity immunoradiometric assay (IRMA) kits for thyroid stimulating hormone (TSH). i.e., RIA BEADS II (kit A), TSH kit Daiichi II (kit B) and Ab tube TSH 'Eiken' (kit C) and one conventional radioimmunoassay (RIA) kit, i.e., TSH kit Daiichi (kit D), were studied. In the recovery test and the reproducibility test, there was no significant difference between the 4 kits. The sensitivities of kits A, B and C were much higher than that of kit D, and those IRMA kits were sensitive enough to distinguish hyperthyroidism from normal samples. For low concentrations of TSH (less than 5 microU/ml), the data from kits D, B, C and A tended to show higher values in that order. The correlation between the data measured by kits B and D, and the tendency of kit A toward lower values agreed well with other reports.

Evaluation Studies as Topic

[Evaluation of pN factors in patients with primary lung cancer by using perfusion, inhalation and ventilation studies].

The interpretation of scintigraphic patterns and the role of pathophysiological mechanisms in patients with primary lung cancer were investigated. To determine the relative roles of perfusion, inhalation and ventilation scintigraphy, the relationship between the count ratio of the affected side to the healthy side and the post-surgical histological lymph nodes factors were observed in this study. These scintigraphic count ratio's in patients with primary lung cancer did not reflect the pN factors except in the perfusion study in patients with hilar primary lung cancer.

Humans

Double aortic arch with aneurysm-a surgical case report.

An unusual case of double aortic arch with aneurysm is described. A 61-year-old, hypertensive and syphilitic male patient complained of increasing difficulty in swallowing of approximately five months duration. Barium swallow and subsequent aortography showed the presence of an aneurysm of the ascending aorta involving the left (anterior) arch of the double aortic arch. The tightening of the vascular ring by aneurysmal dilatation of the left aortic arch appeared to be responsible for the delayed onset of the symptom. Surgical correction was made by removing the aneurysmal ascending aorta and left aortic arch and a Dacron graft was inserted between the ascending aorta and the right (posterior) aortic arch. The patient died of cerebral complication about forty hours postoperatively. Surgical problems associated with this unusual condition were discussed retrospectively from the operative and autopsy findings. In reviewing the pertinent literatures this case appeared to be the first operated case of double aortic arch associated with aneurysm.

Aorta