PubMed Health⌕ Search

Biomedical subjects

I I Stewart

Publications and source records attributed to I I Stewart.

3 recordsLinked to original sources

18O labeling: a tool for proteomics.

An evaluation of the proteolytic labeling and quantification of proteins for diagnostic purposes using trypsin and 18O-enriched H2O is presented. We demonstrate that comparative or relative quantitation can be performed effectively with this approach. We have developed a protocol that allows the conservation of the labeled peptides in natural abundance water without fear of back-exchange providing that pH is sufficiently low to quench the catalytic activity of trypsin, but not so low as to promote chemical back-exchange. Because the labeling efficiency depends on the nature of the peptide, a simple linear relationship between the relative 16O/18O digest buffer mixture content (x) and labeling efficiency (y) does not exist; rather it follows a probability based y = x(2) relationship. As such, the extent of peptide labeling using 16O/18O digest buffer mixture ratios may deviate significantly from that expected based on a linear relationship. The evaluation of the relative Ziptip efficiency indicated a loss in sample recovery as the peptide concentration was reduced using normal conditions, suggesting that there is a limit below which there are diminishing returns. In addition, the adsorptive losses due to Speedvac dry down and recovery indicated modest (20%) losses that may vary widely (0-50%) from peptide to peptide. The in-solution digestion efficiency of standard protein mixtures as a function of concentration revealed a linear decrease with decreasing concentration. This is consistent with enzyme kinetic effects and emphasizes a potential quantitation error that could arise when evaluating differential expression based on peptide detection. The results from our studies demonstrate the power of 18O labeling as an optimization tool for proteomics process development.

Hydrogen-Ion Concentration↗

Investigation of Cr(III) hydrolytic polymerisation products by capillary electrophoresis-inductively coupled plasma-mass spectrometry.

The development of a new method for the determination of Cr(III) hydrolytic polymerisation products using capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) is described. The results indicate that CE-ICP-MS can be used to separate and detect monomeric and polymeric Cr(III) species. The various species migrate through the capillary at a rate proportional to their equilibrium distribution, which is dictated by the solution pH, metal ion concentration and ageing period. In general, the data suggest that the relative mobility follows the order trimer>dimer>monomer. The experimentally determined speciation shows a good qualitative agreement with that described in the literature. Independent confirmation of the presence of polymeric Cr(III) species was performed by ionspray mass spectrometry.

Chromium↗

Time-resolved measurements with single droplet introduction to investigate space-charge effects in plasma mass spectrometry.

An investigation of the space-charge induced effects of high concentrations of Pb+ matrix ions on Li+ analyte ions in inductively coupled plasma mass spectrometry (ICP-MS) is presented using a vertically oriented mass spectrometer with single droplet introduction. Greater reproducibility and stability in droplet-to-droplet sample introduction using the monodisperse microparticulate injector (MDMI) was achieved with the vertical orientation. Typical variation (%RSD) in the droplet-to-droplet arrival times, and mass spectrometry peak analytical areas are better than 5%. With this precision, a more quantitative description of the space-charge effect on a single cloud of ions is obtained. Both radial and axial space-charge effects were found to occur in the ion beam. Radial effects result in a loss in intensity because of poor transmission or collisions at surfaces within the mass spectrometer. Axial effects modify the kinetic energy distribution of background ion beam components (e.g., 16O+ and 40Ar+) and sampled ion cloud constituents (e.g., 7Li+). However, axial effects do not appear to generate significant broadening of sampled ion clouds within the mass spectrometer. At the point of charge separation and high ion-beam charge density, the ion cloud maxima for Li and Pb are not coincident. This is because of mass dependent diffusion in the ICP as the ion clouds approach the sampling orifice. Space-charge induced ion loss occurs predominantly at a localized region after the Li+ sampled cloud peak maximum. When the Pb concentration in the sample is sufficiently high the 7Li+ sampled signal has a bimodal peak shape. The existence of the dip and its relative location in the bimodal 7Li+ sampled signal suggests that space-charge effects are localized to the region of high charge density occurring just after charge separation.

Algorithms↗