PubMed HealthSearch

Biomedical subjects

I J Das

Publications and source records attributed to I J Das.

At least 19 recordsLinked to original sources

Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH).

OBJECTIVE: The dose-volume histogram (DVH) has been accepted as a tool for treatment-plan evaluation. However, DVH lacks spatial information. A new concept, the z-dependent dose-volume histogram (zDVH), is presented as a supplement to the DVH in three-dimensional (3D) treatment planning to provide the spatial variation, as well as the size and magnitude of the different dose regions within a region of interest. MATERIALS AND METHODS: Three-dimensional dose calculations were carried out with various plans for three disease sites: lung, breast, and prostate. DVHs were calculated for the entire volume. A zDVH is defined as a differential dose-volume histogram with respect to a computed tomographic (CT) slice position. In this study, zDVHs were calculated for each CT slice in the treatment field. DVHs and zDVHs were compared. RESULTS: In the irradiation of lung, DVH calculation indicated that the treatment plan satisfied the dose-volume constraint placed on the lung and zDVH of the lung revealed that a sizable fraction of the lung centered about the central axis (CAX) received a significant dose, a situation that warranted a modification of the treatment plan due to the removal of one lung. In the irradiation of breast with tangential fields, the DVH showed that about 7% of the breast volume received at least 110% of the prescribed dose (PD) and about 11% of the breast received less than 98% PD. However, the zDVHs of the breast volume in each of seven planes showed the existence of high-dose regions of 34% and 15%, respectively, of the volume in the two caudal-most planes and cold spots of about 40% in the two cephalic planes. In the treatment planning of prostate, DVHs showed that about 15% of the bladder and 40% of the rectum received 102% PD, whereas about 30% of the bladder and 50% of the rectum received the full dose. Taking into account the hollow structure of both the bladder and the rectum, the dose-surface histograms (DSH) showed larger hot-spot volume, about 37% of the bladder wall and 43% of the rectal wall. The zDVHs of the bladder revealed that the hot-spot region was superior to the central axis. The zDVHs of the rectum showed that the high-dose region was an 8-cm segment mostly superior to the central axis. The serial array-like of the rectum warrants a closer attention with regard to the complication probability of the organ. CONCLUSIONS: Although DVH provides an averaged dose-volume information, zDVH provides differential dose-volume information with respect to the CT slice position. zDVH is a 2D analog of a 3D DVH and, in some situations, more superior. It provides additional information on plan evaluation that otherwise could not be appreciated. The zDVH may be used along with DVH for plan evaluation and for the correlation of radiation outcome.

Breast Neoplasms

Monte Carlo modelling of a virtual wedge.

Compared with a set of physical photon wedges, a non physical wedge (virtual or dynamic wedge), realized by a moving collimator jaw, offers an alternative that allows creation of a wedged field with any arbitrary wedge angle instead of the traditional four physical wedges (15 degrees, 30 degrees, 45 degrees and 60 degrees). It is commonly assumed that non-physical wedges do not alter the photon spectrum compared with physical wedges that introduce beam hardening and loss of dose uniformity in the unwedged direction. In this study, we investigated the influence of a virtual wedge on the photon spectra of a 6-10 MV Siemens MD2 accelerator with the Monte Carlo code EGS4/BEAM. Good agreement was obtained between calculated and measured lateral dose profiles at the depth of maximum dose and at 10 cm depth for 20 x 20 cm2 fields for 6 and 10 MV photon beams. By comparing Monte Carlo models of a physical wedge and the virtual wedge that was studied in this work, it is confirmed that the latter has an insignificant effect on the beam quality, whereas the former can introduce significant beam hardening.

Computer Simulation

Condensed chromatin and cell inactivation by single-hit kinetics.

Mammalian cells are extremely sensitive to gamma rays at mitosis, the time at which their chromatin is maximally condensed. The radiation-induced killing of mitotic cells is well described by single-hit inactivation kinetics. To investigate if radiation hypersensitivity by single-hit inactivation correlated with chromatin condensation, Chinese hamster ovary (CHO) K1 (wild-type) and xrs-5 (radiosensitive mutant) cells were synchronized by mitotic shake-off procedures and the densities of their chromatin cross sections and their radiosensitivities were measured immediately and 2 h into G1 phase. The chromatin of G1-phase CHO K1 cells was dispersed uniformly throughout their nuclei, and its average density was at least three times less than in the chromosomes of mitotic CHO K1 cells. The alpha-inactivation co-efficient of mitotic CHO K1 cells was approximately 2.0 Gy(-1) and decreased approximately 10-fold when cells entered G1 phase. The density of chromatin in CHO xrs-5 cell chromosomes at mitosis was greater than in CHO K1 cell chromosomes, and the radiosensitivity of mitotic CHO xrs-5 cells was the greatest with alpha = 5.1 Gy(-1). In G1 phase, CHO xrs-5 cells were slightly more resistant to radiation than when in mitosis, but a significant proportion of their chromatin was found to remain in condensed form adjacent to the nuclear membrane. These studies indicate that in addition to their known defects in DNA repair and V(D)J recombination, CHO xrs-5 cells may also be defective in some process associated with the condensation and/or dispersion of chromatin at mitosis. Their radiation hypersensitivity could result, in part, from their DNA remaining in compacted form during interphase. The condensation status of DNA in other mammalian cells could define their intrinsic radiosensitivity by single-hit inactivation, the mechanism of cell killing which dominates at the dose fraction size (1.8-2.0 Gy) most commonly used in radiotherapy.

Animals

Lung and heart dose volume analyses with CT simulator in radiation treatment of breast cancer.

PURPOSE: Radiation pneumonitis and cardiac effects are directly related to the irradiated lung and heart volumes in the treatment fields. The central lung distance (CLD) from a tangential breast radiograph is shown to be a significant indicator of ipsilateral irradiated lung volume. Retrospective analysis of the pattern of dose volume of lung and heart with actual volume data from a CT simulator in the treatment of breast cancer is presented with respect to CLD. METHODS AND MATERIALS: The heart and lung volumes in the tangential treatment fields were analyzed in 108 consecutive cases (52 left and 56 right breast) referred for CT simulation. All patients in this study were immobilized and placed on an inclined breast board in actual treatment setup. Both arms were stretched over head to avoid collision with the scanner aperture. Radiopaque marks were placed on the medial and lateral borders of the tangential fields. All patients were scanned in spiral mode with slice width and thickness of 3 mm each, respectively. The lung and heart structures as well as irradiated areas were delineated on each slice and respective volumes were accurately measured. The treatment beam parameters were recorded and the digitally reconstructed radiographs (DRRs) were generated for the measurement of the CLD and analysis. RESULTS: Using CT data the mean volume and standard deviation of left and right lungs were 1307.7+/-297.7 cm3 and 1529.6+/-298.5 cm3, respectively. The magnitude of irradiated volume in left and right lung is nearly equal for the same CLD that produces different percent irradiated volumes (PIV). The left and right PIV lungs are 8.3+/-4.7% and 6.6+/-3.7%, respectively. The PIV data have shown to correlate with CLD with second- and third-degree polynomials; however, in this study a simple straight line regression is used to provide better confidence than the higher order polynomials. The regression lines for the left and right breasts are very different based on actual CT data. The slopes of regression lines for the left and right lung are 0.6%/mm and 0.5%/mm, respectively which is statistically different with thep value of 0.01. A maximum heart PIV of >3.0% is observed in 80% of the patients. The heart PIV is inversely correlated with gantry angle and weakly correlated with CLD. CONCLUSIONS: The CT-simulator provides accurate volumetric information of the heart and lungs in the treatment fields. The lung PIV is directly correlated to the CLD (0.6%/mm and 0.5%/mm for the left and right lungs). Left and right lungs have different volumes and hence, different regression lines are recommended. An additional 12% lung volume could be irradiated in the supraclavicular field. Heart volume is not correlated with the CLD. The heart PIV is associated to the beam angle. Heart volume may not be accurately visualized in a tangential radiograph; however, this can be easily seen in a DRR with contour delineation and can be minimized with proper beam parameters iteratively with a virtual simulator. Lung and heart PIV along with dose volume histograms (DVH) are essential in reducing pulmonary and cardiac complications.

Adult

Monte Carlo dosimetry study of a 6 MV stereotactic radiosurgery unit.

Small-field and stereotactic radiosurgery (SRS) dosimetry with radiation detectors, used for clinical practice, have often been questioned due to the lack of lateral electron equilibrium and uncertainty in beam energy. A dosimetry study was performed for a dedicated 6 MV SRS unit, capable of generating circular radiation fields with diameters of 1.25-5 cm at isocentre using the BEAM/EGS4 Monte Carlo code. With this code the accelerator was modelled for radiation fields with a diameter as small as 0.5 cm. The radiation fields and dosimetric characteristics (photon spectra, depth doses, lateral dose profiles and cone factors) in a water phantom were evaluated. The cone factor (St) for a specific cone c at depth d is defined as St(d, c) = D(d, c)/D(d, c(ref)), where c(ref) is the reference cone. To verify the Monte Carlo calculations, measurements were performed with detectors commonly used in SRS such as small-volume ion chambers, a diamond detector, TLDs and films. Results show that beam energies vary with cone diameter. For a 6 MV beam, the mean energies in water at the point of maximum dose for a 0.5 cm cone and a 5 cm cone are 2.05 MeV and 1.65 MeV respectively. The values of St obtained by the simulations are in good agreement with the results of the measurements for most detectors. When the lateral resolution of the detectors is taken into account, the results agree within a few per cent for most fields and detectors. The calculations showed a variation of St with depth in the water. Based on calculated electron spectra in water, the validity of the assumption that measured dose ratios are equal to measured detector readings was verified.

Brain

Ionization chamber shift correction and surface dose measurements in electron beams.

Cylindrical ionization chambers produce perturbations (gradient and fluence) in the medium, and hence the point of measurement is not accurately defined in electron beam dosimetry. The gradient perturbation is often corrected by a shift method depending on the type of ion chamber. The shift is in the range of 0.33-0.85 times the inner radius (r) of the ion chamber, upstream from the centre of the chamber, depending upon the dosimetry protocol. This variation in shift causes the surface dose to be uncertain due to the high dose gradient. An investigation was conducted to estimate the effective point of measurement of cylindrical ion chambers in electron beams. Ionization measurements were taken with the ion chamber in air and in a phantom at source to chamber distances of <100 cm and >100 cm respectively. The data in air and in the phantom were fitted with the inverse square and electron depth dose functions, respectively. The intersection of the two functions provides an accurate estimate of the ion chamber shift and the surface dose. Our results show that the shift correction for an ion chamber is energy dependent. The measured shifts vary from 0.9r to 0.5r between 6 MeV and 20 MeV beams respectively. The surface dose measured with the ion chambers and mathematically determined values are in agreement to within 3%. The method presented in this report is unambiguous, fast and reliable for the estimation of surface dose and the shift needed in electron beam dosimetry.

Biophysical Phenomena

Validation of a new virtual wedge model.

Results of a validation study of a commercial virtual wedge device recently installed at our institution are presented. The wedge simulation produces an energy fluence from the treatment head that is equivalent to the primary energy fluence attenuated through a wedge-shaped slab of water with the central axis fluence set to unity. A simple exponential formula used to compute off-axis wedge factors is compared to beam profiles measured in a water phantom. A fast Fourier transform (FFT) convolution dose calculation is compared to measured dose profiles. Measured and calculated central axis wedged/open field ratios as a function of depth are also compared.

Calibration

Beam characteristics of a retrofitted double-focused multileaf collimator.

Multileaf collimators (MLCs) are generally believed to be convenient and cost-effective tools for intensity modulation and conformal therapy. They are becoming a standard feature on new accelerators; however, the older units can be retrofitted with modern MLCs. Before such a unit can be clinically used, the beam characteristics must be verified. In this study the beam characteristics of a Siemens double-focused MLC retrofitted to an MD2 linear accelerator are presented. The head leakage along with inter- and intra-leaf radiation transmission were measured using film. The collimator (Sc), phantom (Sp), total (Scp) scatter factors, central axis depth dose, beam profiles for off-axis ratios, penumbra, and surface dose were evaluated for square, rectangular, and irregularly shaped fields. The maximum head leakage was estimated to be < 0.05% in any plane at a distance of 1 m and maximum transmission through the MLC leaves was estimated to be < 1.4% and < 1.1% for the 10 MV and 6 MV beams, respectively. The maximum differences between pre- and post-MLC installation data for the Sc and Scp were < or = 0.7% and < or = 1.4%, respectively. Similarly, the percent depth dose data for all fields and both beam energies were within 1.5% of the original data. The beam profiles measured at various depths were also in agreement with those of the pre-MLC installation data. The measured beam penumbra (20%-80%) showed a range of 7.8 mm-11.0 mm for the 6 MV and 8.4 mm-11.1 mm for the 10 MV beams from smallest to largest fields. These ranges differ by less than a millimeter from those of the old data. The surface dose measurements were slightly lower than the conventional jaw values suggesting that MLC does not produce significant electron contamination. It is concluded that the retrofitted MLC maintains the integrity of the original beam and may provide a cost-effective conformal therapy.

Biophysical Phenomena

Ion recombination and polarity effect of ionization chambers in kilovoltage x-ray exposure measurements.

Exposure measurements with ionization chambers are dependent on the correction factors related to the beam energy (ke), temperature and pressure (ktp), ionization recombination (Pion), and polarity (kpol) effects. In this work, six different chambers commonly used in diagnostic radiology were investigated for the Pion and kpol at various exposure rates by changing the tube voltage, beam current, exposure time, and distance. A special triaxial connector was used to connect chambers to an electrometer capable of measuring positive and negative polarity and 150 V and 300 V electrode potentials to measure the kpol and Pion, respectively. A mammography unit (24-35 kVp) and a diagnostic x-ray unit (60-125 kVp) were used. Results indicate that the magnitude of the Pion is linearly dependent on kVp for large volume (> 150 cm3) chambers and independent for small volume (< or = 150 cm3) chambers. In general, Pion is higher at higher exposures (increasing kVp, mAs, and decreasing distance); however, kpol is independent of exposure rate and kVp, but strongly depends on the sensitive volume of an ion chamber. Pion and kpol vary between 1-48% and 1-16%, respectively, among various chambers and exposure conditions. Chambers with larger volumes have higher values of Pion and kpol. The desired accuracy of +/- 5% in exposure measurements might not be feasible unless both the polarity and recombination effects are known and accounted accurately.

Biophysical Phenomena

Broad beam attenuation of kilovoltage photon beams: effect of ion chambers.

In kilovoltage X-ray treatment, beam shaping and shielding normal tissue are accomplished by thin sheets of lead cutout, the thickness of which is selected based upon either published data or measurements. Available broad beam attenuation (BBA) data are found to be unsatisfactory and are the subject of this investigation. BBA is defined as the ratio of intensity with (I) and without (I0) attenuating medium for a large field in a phantom. BBA = I(x,t,E)/I0(x,0,E), where x is the depth of measurement, t is the thickness of attenuator, and E is the beam energy. The depth x should be zero for kilovoltage beams and dmax for megavoltage beams. Unfortunately, x is limited by the window thickness which is the core of this study. A Farmer-type cylindrical ion chamber and three parallel plate ion chambers (Capintec, PS-033; Markus; and Holt) were used to measure BBA for kilovoltage beams from a Siemens Stabilipan unit. Results indicate that attenuation is strongly dependent on the window thickness. For the 240 kVp beam, the thickness of lead for 5% and 1% transmissions are 3.1 mm, and 5.2 mm, respectively, with the Capintec chamber. The corresponding values of lead thickness for the Markus chamber are 2.3 mm and 4.0 mm; for the Holt chamber the values are 1.1 mm and 2.2 mm; and for the cylindrical chambers the values are 1.1 mm and 2.3 mm, respectively. Similar variabilities in lead thickness with ion chambers were also noted for the other kilovoltage beams. The large differences in lead thicknesses produce enormous clinical errors, especially for shielding eye and other critical structures. For small thickness of lead (< 0.1 mm), a 20-fold increase in surface dose could be observed instead of usual beam attenuation. This is due to intense low energy photoelectrons liberated from lead sheets in the contact with tissue. It is concluded that the lead thickness required to shield normal tissue varies with ion chamber. Until national or international guidelines for broad beam transmission measurements are established, the shielding materials in contact with skin should be coated with a thin (> or = 0.3 mm) low atomic number medium. In such a situation, transmission measurements will be independent of the choice of an ion chamber.

Humans

Radiation fields backscattered from material interfaces: I. Biological effectiveness.

Confluent cultures of CHO-K1 and CHO-xrs5 cells were irradiated attached to 6 microm Mylar with 137Cs gamma rays and 200 kVp X rays adjacent to scattering materials consisting of polystyrene, glass, aluminum, copper, tin and lead. The absorbed dose in cell nuclei was estimated from measurements of backscattered dose made with a parallel-plate ion chamber with a 5-microm Mylar window and a gas volume whose thickness was equivalent to approximately 2.6 microm of cells or tissue. Cell inactivation after various doses was measured by clonogenic assays after trypsinization and enumeration. Survival curves constructed from data pooled from at least two independent experiments were best fitted to a linear-quadratic (LQ) or a linear equation for CHO-K1 and CHO-xrs5 cells, respectively. An average distance of 9.3+/-1.9 microm from the scattering surfaces to the midline of nuclei for both the cell lines was estimated from electron micrographs of fixed cell sections. The major differences in biological effect observed when the cells were irradiated adjacent to these materials could be largely explained by the differences in the physical dose. Further analyses using the LQ equation suggested additional biological effects with implications for the mechanisms involved. CHO-K1 cells showed a small but consistent increase in the low-dose (alpha-inactivation coefficient) mechanism for both radiations scattered from high-Z material. An increased value of the alpha coefficient suggests an increase in RBE which could be associated with a higher proportion of low-energy and track-end electrons in these fields. The radiation fields which produced maximum single-hit killing in CHO-K1 cells also produced less killing by the quadratic (beta-inactivation coefficient) mechanism. In contrast, when similarly irradiated, CHO-xrs5 cells exhibited significantly lower alpha coefficients of inactivation. The mechanistic basis for this opposite effect of backscattered radiations in these cell lines is as yet unknown.

Animals

Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields.

PURPOSE/OBJECTIVE: Acute and chronic small bowel toxicity associated with pelvic irradiation limits dose escalation for both chemotherapy and radiotherapy for rectal cancer. Various surgical and technical maneuvers including compression and belly board devices (BBD) have been used to reduce small bowel volume in treatment fields. However, quantitative dose volume advantages of such methods have not been reported. In this study, the efficacy of BBD with CT-simulation is presented with dose-volume histogram (DVH) analyses for rectal cancer. METHODS AND MATERIALS: Twelve consecutive patients referred to our department with rectal cancer were included in this study. Patients were given oral contrast 1.5 h prior to scanning and instructed not to empty their bladder during the procedure. The initial CT scan without BBD was taken in the prone position with an immobilization cast. A second CT study was performed with a commercially available BBD consisting of an 18-cm thick hard sponge with an adjustable opening (maximum 42 x 42 cm2). All patients were positioned prone over the BBD so that the opening was above the treatment volume and usually extended from the diaphragm to the bottom of the fourth lumbar spine. Image fusion between both sets of CT scans (with and without BBD) was performed using common bony landmarks to maintain the same target volume. The critical structures including small bowel and bladder were delineated on each slice for DVH analysis. On each study, a three-field optimized plan with conformal blocks in beams-eye-view was generated for volumetric analysis. The DVHs with and without BBD were evaluated for each patient. RESULTS: The median age and body weight of 12 patients (4 females and 8 males) were 57.5 years and 82.7 kg, respectively. The changes in posterior-anterior (PA) and lateral separation with and without BBD at central axis slices were analyzed. The changes in lateral separation were minimal (<0.8 cm); however, the PA separation was reduced by 11.3 +/- 3.3% when BBD was used. The reduction in PA separation was directly related to the reduction in small bowel volume. The small bowel volume was significantly reduced with a median reduction of 70% (range 10-100%) compared to the small bowel volume without BBD. The small bowel volume reduction did not correlate either with body weight, age, gender, or sequence of radiation treatment with surgery (pre-op vs. post-op). The DVH analysis of small bowel with BBD showed significant volume reduction at each dose level. For 50% patients, the DVH analysis demonstrated an increase in bladder volume with BBD. All patients treated with the BBD completed their treatment without any break and without significant acute gastrointestinal or genitourinary toxicity. CONCLUSIONS: For rectal cancers, small bowel is the dose-limiting structure for acute and chronic toxicity. The use of the BBD should improve the tolerance of aggressive combined modality treatment by reducing the small bowel volume within the pelvis compared to the prone position alone. The BBD provides an easy, economical, comfortable, and noninvasive technique to displace small bowel from pelvic treatment fields. The small bowel volume is dramatically reduced at each dose level. The volume reduction does not correlate with gender, age, weight, pelvic separation, and sequence of radiation treatment vs. surgery.

Aged

Dosimetric comparison of treatment planning systems in irradiation of breast with tangential fields.

PURPOSE: The objectives of this study are: (1) to investigate the dosimetric differences of the different treatment planning systems (TPS) in breast irradiation with tangential fields, and (2) to study the effect of beam characteristics on dose distributions in tangential breast irradiation with 6 MV linear accelerators from different manufacturers. METHODS AND MATERIALS: Nine commercial and two university-based TPS are evaluated in this study. The computed tomographic scan of three representative patients, labeled as "small", "medium" and "large" based on their respective chest wall separations in the central axis plane (CAX) were used. For each patient, the tangential fields were set up in each TPS. The CAX distribution was optimized separately with lung correction, for each TPS based on the same set of optimization conditions. The isodose distributions in two other off-axis planes, one 6 cm cephalic and the other 6 cm caudal to the CAX plane were also computed. To investigate the effect of beam characteristics on dose distributions, a three-dimensional TPS was used to calculate the isodose distributions for three different linear accelerators, the Varian Clinac 6/100, the Siemens MD2 and the Philips SL/7 for the three patients. In addition, dose distributions obtained with 6 MV X-rays from two different accelerators, the Varian Clinac 6/100 and the Varian 2100C, were compared. RESULTS: For all TPS, the dose distributions in all three planes agreed qualitatively to within +/- 5% for the "small" and the "medium" patients. For the "large" patient, all TPS agreed to within +/- 4% on the CAX plane. The isodose distributions in the caudal plane differed by +/- 5% among all TPS. In the cephalic plane in which the patient separation is much larger than that in the CAX plane, six TPS correctly calculated the dose distribution showing a cold spot in the center of the breast contour. The other five TPS showed that the center of the breast received adequate dose. Isodose distributions for 6 MV X-rays from three different accelerators differed by about +/- 3% for the "small" patient and more than +/- 5% for the "large" patient. For two different 6 MV machines of the same manufacturer, the isodose distribution agreed to within +/- 2% for all three planes for the "large" patient. CONCLUSION: The differences observed among the various TPS in this study were within +/- 5% for both the "small" and the "medium" patients while doses at the hot spot exhibit a larger variation. The large discrepancy observed in the off-axis plane for the "large" patient is largely due to the inability of most TPS to incorporate the collimator angles in the dose calculation. Only six systems involved agreed to within +/- 5% for all three patients in all calculation planes. The difference in dose distributions obtained with three accelerators from different manufacturers is probably due to the difference in beam profiles. On the other hand, the 6 MV X-rays from two different models of linear accelerators from the same manufacturer have similar beam characteristics and the dose distributions are within +/- 2% of each other throughout the breast volume. In general, multi-institutional breast treatment data can be compared within a +/- 5% accuracy.

Body Constitution

Dose estimation to critical organs from vertex field treatment of brain tumors.

PURPOSE: Radiation management of intracranial tumors may require a noncoplanar vertex field that often irradiates the entire length of the body. In view of radiation related risks to the normal tissues dose estimation to the extracranial organs such as the thyroid gland, spinal cord, heart, and genitalia is performed for a vertex field. METHODS AND MATERIALS: A vertex field used clinically was reproduced on an anthropomorphic Rando phantom to measure radiation dose to various organs in the primary beam. Three photon beams (4, 6, and 10 MV), and two high energy electron beams (16 and 20 MeV) were used. Dosimetry was performed with an ion chamber sandwiched between phantom slices at the appropriate positions. All doses were normalized to the target dose at a depth of 5 cm. The effect of the head position was studied by rotating the gantry angle up to +/-20 degrees to mimic the extension and flexion of the head. Theoretical calculation was performed using an exponential best fit to the depth dose table to estimate the dose to various points and compare with the measured dose. RESULTS: The measured normalized dose to the cervical cord, thyroid, heart, and female and male gonads are 60, 36, 16, 2.5, and 1.6%, respectively, for a 6 MV photon beam. The dose from 4 MV and 10 MV are slightly lower and higher, respectively. Doses from electron beams are about a factor of 4-10 lower than those of the photon beams. The measured gonadal dose from the primary beam is <5% of the target dose for all energies used in the study. The actual value, however, is dependent on the body structure, length, and the posture of the patient. A +5 degree head flexion had little effect on the dose to the various parts of the body. The head rotations greater than +/-10 degrees produced relatively lower doses by a factor of 10(-2) to the organs at distances greater than 40 cm from the prescription point. The radiation doses to the different critical organs estimated from the fitted curves are lower than the measured doses up to 35%. CONCLUSIONS: When a vertex field is used for the treatment of the brain tumors, the entire axial length of the body is irradiated which adds to the integral dose. Unlike the scattered and leakage radiation, the primary dose to extracranial critical organs is greater for higher energies. For a 10 MV beam the ovary and testis at a distance of 80 cm and 90 cm may receive a dose of 4.2 and 3%, respectively, of the target dose. The gonadal dose could be quite significant if the entire treatment is delivered using a vertex field. For pediatric and smaller patients, dose to the critical organs at known distances could be estimated from the empirical equation obtained from the measured data. While the risk-benefit ratio is often evaluated and acceptable for treating malignant tumors, the long-term complications need thorough assessment in younger and curable patients. In view of radiation carcinogenesis and genetic burden, dose reduction to critical organs should be considered using a 3D planning system to arrange beams in other nonaxial planes and by considering electron beams for the vertex field.

Brain Neoplasms

Patterns of dose variability in radiation prescription of breast cancer.

PURPOSE: Comparison of radiation outcome of various treatment protocols is difficult due to the variability of dose prescription. A retrospective analysis of the pattern and intercomparison of dose prescriptions is presented for the treatment of breast cancer. MATERIALS AND METHODS: To represent the clinical practice for breast irradiation with tangential fields, commonly used prescription points were chosen that lie on the perpendicular bisector of the chest wall separation (s) that represents the breast apex height (h). These points are located at 1.5 cm from the posterior beam edge, at the chest wall-lung interface (2-3 cm), at distances of h/3 and h/2, and at the isocenter. One hundred consecutive patients treated with intact breast following excisional biopsy were used in this study. For analysis, treatment planning was carried out without lung correction with a 6 MV beam for all patients, even though some of the patients were treated with high energy beams for dose uniformity. Dose distributions were optimized with wedges and beam weights to provide a symmetrical dose distribution on the central axis plane. The statistical analyses of the different parameters, s, h, maximum dose, and doses at various prescription points were carried out. RESULTS: The maximum dose (hot spot) in breast varied from +5% to +27% above the prescribed dose among the patient population. The hot spot was directly related to s, and appeared to be independent of h and the ratio h/s. Among 55%, 40%, and 5% of the patients, the magnitude of the hot spot was 5-10%, 10-15%, and >15%, respectively. Except for the magnitude of the hot spot, the doses at various prescription points were independent of the breast size. For a prescription point at h/3 or at the lung-chest wall interface, the dose variation within +/- 1% is observed for 90% of the patient population. On the other hand, the average dose variation is about +/- 3% among other protocols with dose prescription point varying up to the h/2 point. With the prescription point at the isocenter, an average and maximum variation of 4-5% and 11% were observed, respectively. The maximum dose inhomogeneity for some patients was significantly higher, i.e. up to +27% even without the lung correction. CONCLUSIONS: A wide variation in prescription dose is observed among the different treatment protocols commonly used in breast treatment. For a total dose of 46-50 Gy delivered at 2 Gy/fraction to the breast, the prescribed dose may vary between 50 and 55 Gy and the hot spot dose per fraction may range between 2.3 and 2.5 Gy depending on the protocol and breast size. Thus dose normalization at hot spot and the isocenter should be discouraged unless the total dose to the breast is modified. A uniform definition of dose prescription for breast treatment is greatly required for intercomparison of clinical data.

Breast Neoplasms

Forward dose perturbation at high atomic number interfaces in kilovoltage x-ray beams.

High atomic number (Z) materials such as lead, used for field shaping and shielding normal tissues in kilovoltage beams could produce significant dose enhancement in the forward direction contrary to our normal belief with respect to the attenuation of photon beams. Such a dose enhancement has not been studied in kilovoltage beams, which is investigated in this study. Using a Siemens ortho-voltage unit (60-240 kVp) and a thin window (5 microns) parallel plate ion chamber, forward dose perturbation factor (FDPF) was measured at interfaces created by high- and low-Z materials. The FDPF is defined as the ratio of doses with and without an interface (FDPF = Di/Dh; where Di is the dose at an interface and Dh is the dose in a homogeneous medium). Results indicate that dose enhancement (FDPF > 1) as high as 20-fold can be observed for a thin (> or = 0.02 mm) Pb sheet in contact with soft tissue. The magnitude of FDPF is relatively independent of field size and falls off exponentially with Pb thickness. The typical photon beam attenuation takes at a thickness > 1 mm. This intense dose enhancement is localized within 250 microns of the interface. The FDPF is energy dependent but saturates above 140 kVp, unlike the backscatter dose perturbation that peaks around 200 kVp. The FDPF varies inversely with the thickness of high Z and distance between the surface and high-Z medium. The FDPF falls off rapidly to a level of photon transmission usually predicted by exponential attenuation when distance is increased. In conclusion, with kilovoltage beam, a high-Z medium placed in contact with soft tissue may not attenuate radiation dose unless adequate thickness and proper distance between the surface and high-Z medium is used. The localized intense dose enhancement (approximately 20-fold) created by the high-Z interface could be exploited for clinical use.

Biophysical Phenomena

Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit.

A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be < 0.5 mm with a compounded accuracy of < or = 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within +/- 0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed.

Equipment Design