PubMed Health⌕ Search

Biomedical subjects

I Kósa

Publications and source records attributed to I Kósa.

9 recordsLinked to original sources

[Laparoscopic cardiomyotomy in the treatment of achalasia].

The laparoscopic cardiomyotomy (Heller) with Dor type anterior fundoplication is accepted for treatment of esophageal achalasia. Between December 1994 and December 1998, 21 patients with esophageal achalasia underwent laparoscopic Heller's operation with Dor's antireflux procedures after preoperative assessment which involved radiological, endoscopic and manometric investigations. Results were evaluated on the basis of our experiences and postoperative investigations. There were no intraoperative complications. Operating time was 40-90' (mean 65'). Conversion to laparotomy was not required. One patient had postoperative stenosis, and another had esophageal perforation which was treated. Postoperative manometry in all patients showed a decreased lower esophageal sphincter pressure. Based on the obtained results it could be concluded that cardiomyotomy with Dor fundoplication through a laparoscopic approach leeds to good functional results and seems effective and safe procedure in the treatment of esophageal achalasia.

Adolescent↗

Myocardial perfusion scintigraphy to evaluate patients after coronary stent implantation.

UNLABELLED: Coronary stent implantation is an increasingly accepted revascularization method. The 20%-30% restenosis rate during the first 6 mo requires a close follow-up of the patients. Since there is very little data available defining the role of perfusion scintigraphy in the management of this population, the aim of this study was to assess the diagnostic performance of stress myocardial perfusion imaging for detecting restenosis in patients after coronary stent implantation. METHODS: In 82 patients, 93 rest or stress SPECT studies were performed using 201Tl and 99mTc-hexakis-2-methoxyisobutyl isonitrile to evaluate 99 vascular territories with implanted coronary stents. The average interval between the stent implantation and the scintigraphic study was 210.5 +/- 129.6 days. The scintiscans were visually evaluated. A stress-induced perfusion defect with reversibility at rest was used as the criterion for stent restenosis. RESULTS: Coronary angiography revealed a stenosis of > 50% diameter in the region of the stent in 19 arteries, while in 80 arteries there was no evidence of restenosis angiographically. With perfusion scintigraphy, 15/19 vascular territories with restenosed stents showed stress-induced perfusion abnormalities (sensitivity = 79%), while 62/80 territories without restenosis did not (specificity = 78%). In territories without a myocardial infarction (n = 48), sensitivity and specificity values were 8/8 (100%) and 36/44 (82%), and in territories with a myocardial infarction (n = 47) 7/11 (64%) and 26/36 (72%), respectively. Side branch stenosis was fairly frequent in patients without stent restenosis but with a reversible perfusion pattern on their scintiscan (8/18); however, these stenoses were induced infrequently by the stents (3 cases). CONCLUSION: Using the criterion of defect reversibility, stress perfusion SPECT can accurately detect restenoses of coronary artery stents. This method is most accurate for evaluating patients without a previous myocardial infarction in the stented vascular territory.

Coronary Disease↗

Recovery of myocardial perfusion in acute myocardial infarction after successful balloon angioplasty and stent placement in the infarct-related coronary artery.

OBJECTIVES: This study sought to investigate changes in myocardial perfusion after direct percutaneous transluminal coronary angioplasty (PTCA) in acute myocardial infarction (MI). BACKGROUND: After initially successful recanalization of the infarct-related artery, coronary perfusion may deteriorate as a result of reocclusion, distal embolization of platelet aggregates formed at the dilated plaque or microvascular reperfusion injury. This change could offset the benefit from early intervention. METHODS: The study included 19 patients in whom the infarct-related artery was successfully recanalized by PTCA with Palmaz-Schatz stent placement within 24 h after the onset of pain. Basal and papaverine-induced coronary blood flow were assessed by Doppler flow velocity measurements and quantitative coronary angiography. In addition, basal and adenosine-induced myocardial blood flow were measured by nitrogen-13 ammonia positron emission tomography (PET). RESULTS: Immediately after completion of the intervention, the average coronary flow reserve (CR) in the recanalized vessel was 1.56 +/- 0.51; it increased to 2.04 +/- 0.65 at 1 h (p = 0.013) and to 2.66 +/- 0.72 at 2 weeks after reperfusion (p = 0.008, n = 16). PET studies in 12 patients revealed that perfusion defect size and CR in the infarct region (2.19 +/- 0.89 vs. 2.33 +/- 0.86) did not change significantly between day 2 after recanalization and 2 weeks. However, we found significant (p < 0.03) increases in basal (by 26%) and adenosine-induced (by 40%) blood flow in the infarct region. CONCLUSIONS: Despite the persistence of a perfusion defect after successful recanalization of the occluded artery in acute MI, CR of the infarct region improves in most patients within 1 h and further improves within 2 weeks.

Adult↗

Prospective evaluation of thallium-201 reinjection in single-vessel coronary patients undergoing coronary bypass surgery.

Twenty-two patients with single-vessel left anterior descending coronary artery disease were investigated by means of dipyridamole stress thallium-201 myocardial perfusion scintigraphy, using single photon emission tomography (SPET), 1 week before and 2-5 weeks after coronary bypass surgery. The dose of dipyridamole was 0.56 mg/kg, and the injected activity of 201Tl was 74 MBq. Before surgery, and after completion of the redistribution study, a further 37 MBq of 201Tl was injected. Ten minutes and 1 h later, repeated SPET imaging were performed. SPET images were evaluated both subjectively and semiquantitatively, using a five-grade segmental defect score system, with higher scores for more severe perfusion defects. Before surgery, the 3-h redistribution images revealed complete or partial persistence of the perfusion defects in all patients. On the images taken 10 min after reinjection, these defects were completely filled in four cases, and partially filled in ten cases. Further positive changes were observed on the 1-h post-reinjection images in four cases. Three of the 1-h post-reinjection images exhibited a paradox redistribution. The stress images after surgery corresponded well to the 201Tl distribution on the preoperative 1-h post-reinjection images in 11 cases. The average of the segmental defect severity scores was 17.0 after stress, 10.1 at rest, 7.1 10 min after reinjection and 6.4 1 h after reinjection. After surgery, the average of both the post-stress and the 3-h redistribution scores was 3.1.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Artery Bypass↗

[False positive results of exercise tests with thallium myocardial scintigraphy].

The authors have examined supposed causes of positive Th-201 stress scintigraphy. Patients were divided into two groups according to the presence of exercise-induced transitory hypoperfusion or in absence of it. In both groups negative coronarograms were verified. Results of two groups were compared according to parameters of the left ventricle function, pulmonary pressure, to the presence of disorder of system stimulus-conduction (LBBB, RBBB), mitral prolapsus, foramen ovale apertum, anomalous coronary anatomy, level of load during exercise, body weight, heart volume-index. Significant difference was found in disorder of left ventricle motion, ejection fraction and in comprehensive value of left ventricle function (F1).

Adult↗

[Ergometric stress test using Tl-201 myocardial perfusion. Tomographic or planar imaging?].

The clinical performance of the planar vs. tomographic ergometric stress 201-Tl myocard perfusion scintigraphy was compared. The results of the investigations of 80 patients were analysed retrospectively. In 59 patients planar, in 21 tomographic imaging was performed. As a consequence of clinical decision making cardiac catheterization was made in all of the patients, within 3 months after the perfusion scintigraphy. The sensitivity of the planar method was 23/27 (85%), the specificity 18/32 (56%), the accuracy 41/59 (69%). The respective values of the SPECT technique were: Sensitivity: 12/12 (100%), specificity 6/9 (66%), accuracy 18/21 (86%). It is concluded, that in comparison to the planar imaging the SPECT technique is superior in the detection of the perfusion abnormalities of the myocard due to significant coronary narrowings.

Coronary Disease↗

[Cardiolite (99m-Tc-isonitrile) SPECT studies in patients prior to coronary bypass surgery].

The authors studied with 99m-Tc Cardiolite (methoxy-isobutyl-isonitrile) SPECT examination the effect of coronary bypass operation on the myocardial perfusion. One week before and 3 weeks after the operation examinations were performed first with dipyridamol loading and 24 hours later in rest. The regional perfusion of the myocardium was studied on the basis of transversal section-pictures of corrected axis position. In the examinations preceding the operation the global sensitivity of the method was found to be 100%. In the demonstration of the structures of the ramus descendens 95%, of the ramus circumflexus and of the right coronary artery 100% sensitivity was reached. In postoperative examinations following the bridging of the ramus descendens anterior the improvement of the perfusion of the corresponding ventricular segment was found in 15/20 during the loading and in 7/8 cases following the bridging of the ramus circumflexus and right coronary artery. Improving perfusion was demonstrated in 17/20 and in 6/8 cases in rest. On the basis of the results the authors consider their method suitable for the study of the regional blood perfusion and for the examination of the changes taking place upon coronary bypass operations.

Aged↗

Complications after large vein catheterization.

Serious complications of the introduction of pacemaker electrodes and of the catheterization of large veins performed in the course of 6 years are discussed. The majority of the 24 observed complications occurred on the left side. In the case of constant suction and thoracic haemorrhage, surgical exposure is unavoidable. In five cases the complications were due to temporary pacemaker electrodes. Four of the patients died of organ damage. Three typical case records are presented.

Adult↗