PubMed Health⌕ Search

Biomedical subjects

I Lundström

Publications and source records attributed to I Lundström.

At least 73 records · Page 4Linked to original sources

Bactericidal properties of a titanium-peroxy gel obtained from metallic titanium and hydrogen peroxide.

A stable titanium-peroxy-radical complex is formed when metallic titanium interacts with hydrogen peroxide. The radical appears as one component in an aqueous gel formed when excess peroxides have been (catalytically) decomposed. The interaction between titanium and hydrogen peroxide may be of importance also in vivo during an inflammatory response at the implant. We report in this paper on the bactericidal effects of the titanium gel in the lacto- and myeloperoxidase-halogen systems. Escherichia coli viable count was used to evaluate the bactericidal properties of the gel and of H2O2 for comparison. The gel had only small or no toxic properties at high dilutions. Higher concentrations of the gel had bactericidal properties similar to those of H2O2. The results indicate that at physiological pH, the decomposition products of the gel ae titanium hydroxide (Ti(IV)(OH-)4) and hydrogen peroxide (H2O2). It was found that the gel probably oxidizes glutathione directly in contrast to H2O2, which needs a peroxidase to do so. A model for the interaction between titanium and hydrogen peroxide is suggested. Its consequences for the properties of titanium in vivo are also discussed.

Chlorine↗

Fish scales as biosensors for catecholamines.

Certain fish scales contain specialized cells (chromatophores) with pigment granulas, which can be dispersed or aggregated in the cells. The degree of aggregation is determined by a transmitter substance, noradrenaline, released by the sympathetic nerve endings in the skin. Isolated scales from, for example, cuckoo wrasse (Labrus ossifagus) retain a large sensitivity to externally applied noradrenaline (or more generally catecholamines) for several weeks. The degree of aggregation in isolated scales can be measured objectively by simple photometric techniques. We demonstrate in this paper how fish scales can be used to monitor catecholamine levels in human blood plasma. A discussion of other potential biosensor applications of this intact biological receptor-effector system is also given.

Animals↗

Titanium-hydrogen peroxide interaction: model studies of the influence of the inflammatory response on titanium implants.

In vitro studies of titanium and TiO2 as well as other metals were carried out to investigate the role of these metals in the inflammatory response through the Fenton reaction. The TiOOH matrix formed traps the superoxide radical, so that no or very small amounts of free hydroxyl radicals are produced. Ellipsometry and spin trapping with spectrophotometry and electron spin resonance (ESR) were used to study the interaction between Ti and H2O2. Spectrophotometry results indicated that Ti, Zr, Au and Al are low free OH-radical producers. We propose a new model for the titanium-tissue interface where the oxidized titanium surface is covered with a hydrated TiOOH matrix after the inflammatory reaction. This matrix is suggested to possess good ion exchange properties, and extracellular components may interact with the Ti(IV)-H2O2 compound before matrix formation. The TiOOH matrix is formed when the H2O2 coordinated to the Ti(IV)-H2O2 complex is decomposed to water and oxygen. Superoxide (O2-) may be bound therein. The oxide layer initially present may be partly reformed to a TiOOH matrix due to the interaction with hydrogen peroxide.

Biocompatible Materials↗

Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium.

Hydroxyl radicals formed from hydrogen peroxide during an inflammatory response are potent agents for cellular deterioration. The behaviour of implanted material in terms of its ability to sustain or stop free radical formation may be therefore very important. In vitro studies of titanium which is known to be biocompatible and osseointegrates into human bone were carried out. In our model studies, the production of free radicals from H2O2 at Ti and TiO2 surfaces was measured by spin trapping techniques. Our findings suggest that there is no sustained hydroxyl radical production at a titanium (oxide) surface. We propose that this is due to the quenching of the Fenton reaction through both trapping and oxidation of superoxide radicals in a TiOOH adduct.

Biocompatible Materials↗

Determination of haemoglobin and prothrombin complex in whole blood using optothermal spectrometry.

Optothermal spectrometry measures the thermal energy produced as a result of absorption by molecules at a given modulation frequency and wavelength. Depending on the modulation frequency used, analysis can be performed in very thin layers (50-150 micrometers). A major advantage of optothermal spectrometry is that it is not very sensitive to light scattering. Haemoglobin in whole blood was measured without any reagent at 16 Hz and 2 Hz frequencies. The precisions (within-series, within-day and between-day) were acceptable, and comparisons with reference methods were excellent. As opposed to the reference methods, optothermal spectrometric determinations were not affected by lipaemia. When measured continuously, the signal for haemoglobin increased due to the packing of erythrocytes towards the light source. By converting soluble fibrinogen into insoluble fibrin, the erythrocyte packing could either be inhibited or stopped, and this process could be monitored by assessing the change in the rate of signal increase for haemoglobin. This principle was utilized to analyse the prothrombin complex; the method was found to have acceptable precision and to be comparable to a routine method.

Blood Coagulation Factors↗

Competition between adsorbed fibrinogen and high-molecular-weight kininogen on solid surfaces incubated in human plasma (the Vroman effect): influence of solid surface wettability.

The influence of the surface energy on the competition between fibrinogen and high-molecular-weight kininogen has been studied with the use of a recently described wettability gradient method. One finding is that the decrease in the antifibrinogen binding on plasma incubated gradient surfaces was not associated with an increase in anti-HMWK binding at all parts of the gradient surfaces.

Adsorption↗

Non-chromogenic peptide substrates for detection of enzymes by means of capacitance changes at metal electrodes.

A new type of substrate for enzyme detection has been developed. The substrate is non-chromogenic and is used in an assay method based on electrode adsorption. The rate of change in the electric capacitance of the electrode is monitored and taken as a measure of the substrate adsorption. Substrate adsorption is in turn proportional to substrate bulk concentration and thus subject to changes by enzymes. The new substrate introduces a new concept in enzyme detection: as it is non-chromogenic it may contain appropriate amino acids on both sides of the bond subject to enzymatic cleavage.

Electrochemistry↗

Complement deposition from human sera on silicon surfaces studied in situ by ellipsometry. The influence of surface wettability.

Organic material deposition from human sera on silicon dioxide surfaces was studied in situ by means of ellipsometry, an optical method for quantification of thin organic films. The deposition of organic material from sera was followed continuously for 2 h on hydrophobic and hydrophilic silicon surfaces. Both types of surfaces adsorbed organic material and the additional incubation with anti-C3 resulted in further deposition of organic material indicating the presence of C3 in the organic layers. Addition of EDTA in serum or heat inactivation resulted in a decrease of the amount of organic material deposited on the hydrophobic surface as well as in a lack of subsequent anti-C3 deposition on both hydrophilic and hydrophobic surfaces. Preadsorption with immunoglobulin G on the surfaces caused a pronounced increase of the deposition of material from serum as well as of subsequent anti-C3 deposition. Both effects were absent if EDTA was present in the serum. Our results indicate that complement activation and deposition occur by incubation of human sera on hydrophobic and hydrophilic silicon dioxide surfaces, which are two surfaces with very simple and well-defined chemical composition. The degree of the reversibility of the deposition of immunoglobulin G was furthermore larger on hydrophilic silicon.

Complement Activation↗

Reversible and specific interaction of dehydrogenases with a coenzyme-coated surface continuously monitored with a reflectometer.

Reversible affinity binding of NAD-dependent dehydrogenase to an NAD-coated silicon surface ("NAD biochip") has been accomplished. The silicon surface, which is favorable for use with optical techniques because of its excellent reflection properties, was precoated with a polymer to prevent nonspecific and irreversible adsorption. Using a new reflectometry technique based on measurement of the polarization change of light reflected upon the biochip, continuous monitoring of the affinity binding and subsequent desorption of alcohol dehydrogenase and lactate dehydrogenase from the NAD surface were possible; allowing repeated use of the same NAD chip--an advantage when the assay was carried out in a continuous reflectometer. With a flow rate of 0.5 ml/min, response times on the order of 30 s were obtained.

Adsorption↗

A reflectance method for quantification of immunological reactions on surfaces.

A simple optical method for determination of thicknesses of organic layers on solid substrates is described. The method is based on the use of a substrate with a high refractive index, e.g., silicon, and reflection of light at an angle of incidence close to the pseudo-Brewster angle. Under these conditions, a reflectance minimum is obtained for light polarized in the plane of incidence. The presence of an organic layer on the surface will increase the reflectance, which is used to determine the thickness of the layer. The physical basis of the method is described briefly, and the application to immunology is demonstrated.

Antigen-Antibody Reactions↗

Determination of molecular hydrogen in investigations of the susceptibility of Enterobacteriaceae to ampicillin.

One hundred and five enterobacterial isolates from urinary tract infections were examined for ampicillin-susceptibility by measurement of molecular hydrogen production with a palladium metal oxide semi-conductor (Pd-MOS sensor). Eighty-one per cent of hydrogen producing strains could be placed in the same susceptibility groups as recorded by disc-diffusion tests. However, it was harder to separate susceptible from intermediate types than to determine resistance. In all but five strains the hydrogen production allowed determination of viability within 5 h.

Ampicillin↗

Hydrogen concentration in expired air analyzed with a new hydrogen sensor, plasma glucose rise, and symptoms of lactose intolerance after oral administration of 100 gram lactose.

A rapid breath hydrogen analyzer to detect lactose malabsorption is described. After ingestion of a lactose solution the patient expires into a mouthpiece attached to a hydrogen sensor at 30-min intervals for 3 1/2 h. The hydrogen of the expired air causes a voltage change that can be transformed into ppm from a calibration curve. A tolerance test with a load of 100 g lactose was performed in 43 consecutive patients with various gastrointestinal disturbances, referred to the laboratory for the commonly used lactose tolerance test based on plasma glucose measurements. Eleven patients developed symptoms of lactose intolerance during the test. Biopsy specimens from the distal duodenum or proximal jejunum showed partial villous atrophy in one, in whom celiac disease with lactose intolerance was diagnosed; the other 10 had normal specimens. In nine of them lactose intolerance was diagnosed and confirmed by observation for months on a lactose-poor diet. The 10th patient (H.P.L.) did not improve on such a diet. He also showed pronounced symptoms of intolerance during a test with monosaccharides (glucose + galactose). His intestinal disease remained undiagnosed. The 11 patients with symptoms of intolerance and 3 patients without symptoms during the lactose load showed a flat plasma glucose curve after drinking the lactose solution--that is, a maximum rise of the glucose concentration of 1.5 mmol/l. One of the symptom-free patients dropped out and could not be observed, another did not improve on a lactose-poor diet, and the third noticed a favorable effect of the diet on stool consistency but not on other abdominal symptoms.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗