PubMed Health⌕ Search

Biomedical subjects

I M Brook

Publications and source records attributed to I M Brook.

At least 19 recordsLinked to original sources

In vitro biocompatibility of fluorcanasite glass-ceramics for bone tissue repair.

Fluorcanasite glass-ceramics were produced by controlled two stage heat-treatment of as-cast glasses. These glasses were modified from stoichiometric fluorcanasite composition by either adding P(2)O(5) or altering the molar ratios of Na(2)O and CaO. Commercial bioactive 45S5 Bioglass(R) was also prepared in-house to evaluate the relative in vitro biocompatibility of fluorcanasite glass-ceramics. The scanning electron microscopy (SEM) images showed that cells had colonized the surfaces of fluorcanasite glass-ceramics to form a confluent sheet. Quantitative MTT assay results were in good agreement with the qualitative SEM observations. It was concluded that incorporation of excess calcium oxide or P(2)O(5) in stoichiometric glass composition improved in vitro biocompatibility. Controlled heat-treatment further improved the biological response of cultured bone cells to modified fluorcanasite glass-ceramics when compared with their parent glasses. Ion release and pH data suggested a strong correlation between solubility (in particular, Na ion release) and biocompatibility. Reduced solubility, Na ion release, and related pH effects appeared to be the principal mechanisms responsible for improvement in in vitro biocompatibility.

Animals↗

HPLC analysis of components released from dental composites with different resin compositions using different extraction media.

Components released from dental composite resins are essential factors in the assessment of biocompatibility of these materials. The effect of different extraction media on monomer release from composite resins based on different monomer types was evaluated. Three types of visible light cured composite resins were formulated based on the following monomers: triethylene glycol dimethacrylate (TEGDMA), bisphenol A glycerolate dimethacrylate (BisGMA), and urethane dimethacrylate (UDMA). Seventy-five composite resin discs were fabricated and light cured for 1 min in the absence of oxygen. Extraction media used were: distilled water, saline solution, artificial saliva, serum-free culture medium, and culture medium with 10% fetal calf serum. The analysis of extracts from the composite resins was carried out by High Performance Liquid Chromatography (HPLC). Quantifiable amounts of TEGDMA were released into the aqueous media. However, BisGMA and UDMA were not detectable in any of the extracts from the composite resins. Statistical analysis by one-way ANOVA followed by Tukey's test showed that there was a significant difference in TEGDMA release between culture media and other media (p < 0.05). From the results of this experiment it can be concluded that TEGDMA-based composite resins can release a high quantity of monomer into aqueous environments. The type of extraction medium may have a significant effect on monomer release from composite resins.

Biocompatible Materials↗

Biocompatibility of glass-ionomer bone cements.

Glass-ionomer cements (GIC) have been extensively used in dentistry for over 30 years. Due to their excellent biocompatibility in dental applications GIC have been formulated for medical applications. The past decade has seen some impressive advances in the development of medical GICs, however these advances have been matched by serious critical problems. This review examines the properties of GICs, which can influence their behaviour in a biological environment. The progress made and the problems encountered in the development of these bone cements will also be addressed. The review will conclude with the research currently being employed to optimise the biocompatibility of these important biomaterials. There is little doubt that GICs compare favourably with alternative bone cements for specific applications, based on in vitro and in vivo studies. There is however, a degree of risk inherent in the use of any medical device or biomaterial. GICs must therefore be used carefully and in accordance with the instructions that are based on a significant body of research data.

Aluminum↗

Bone response to a titanium aluminium nitride coating on metallic implants.

The design, surface characteristics and strength of metallic implants are dependant on their intended use and clinical application. Surface modifications of materials may enable reduction of the time taken for osseointegration and improve the biological response of bio-mechanically favourable metals and alloys. The influence of a titanium aluminium nitride (TAN) coating on the response of bone to commercially pure titanium and austenitic 18/8 stainless steel wire is reported. TAN coated and plain rods of stainless steel and commercially pure titanium were implanted into the mid-shaft of the femur of Wistar rats. The femurs were harvested at four weeks and processed for scanning electron and light microscopy. All implants exhibited a favourable response in bone with no evidence of fibrous encapsulation. There was no significant difference in the amount of new bone formed around the different rods (osseoconduction), however, there was a greater degree of shrinkage separation of bone from the coated rods than from the plain rods (p = 0.017 stainless steel and p = 0.0085 titanium). TAN coating may result in reduced osseointegration between bone and implant.

Aluminum Compounds↗

Crystallization modifies osteoconductivity in an apatite-mullite glass-ceramic.

The response to implantation of novel apatite glass-ceramics was evaluated using a weight bearing in vivo bone implant model. Five novel glasses with varying calcium to phosphate ratios were cast as short rods and heat-treated to crystallize principally apatite. One glass ceramic had an apatite stoichiometry (Ca : P=1.67); three were phosphate-rich and one calcium-rich. One of the phosphate-rich glasses was also tested in its glassy state to determine the effect of crystallization on the biological response. Rods were implanted into the midshaft of rat femurs and left for 28 days. The femurs were then harvested and processed for scanning electron microscopy, energy dispersive X-ray microanalysis and conventional histology as ground and polished sections. Four of the materials exhibited evidence of osseointegration and osteoconduction. However, there was a marked inflammatory response to one of the phosphate-rich glass-ceramics, and to the non-crystallized glass. Crystallization of the latter significantly improved the bone tissue response. The glass-ceramic with an apatite stoichiometry elicited the most favorable response and merited further study as an osteoconductive bone substitute in maxillofacial and orthopedic surgery.

Journal Article↗

Implant treatment.

Explore the source record for details and available documents.

Alveolar Bone Loss↗

In vivo response of strontium and zinc-based ionomeric cement implants in bone.

In this study the osteoconductive properties of strontium based ionomeric cements (ICs) named, LG125 and LG119, as well as zinc-based ICs, designated by LG130 and LG132, were compared. Wet ICs were surgically implanted into the femora of weaned Wistar rats for 4 weeks. To assess the percentage osseointegration the perimeter of the implant and the perimeter of bone in contact with the implant were measured using a pointer (the length of bone/implant interfacial contact). Osteoconduction was determined by taking six points at random around the perimeter of each ionomeric rod measuring the thickness of newly formed bone. The degree of osteoconduction was taken as the average thickness of new bone produced on the implant surface. It was found that osteoconduction was greatest in the strontium based IC implant LG125. From these studies it can be concluded that the composition LG125 might provide a useful purpose as a bone cement.

Journal Article↗

In vitro and in vivo evaluation of e-PTFE and alkali-cellulose membranes for guided bone regeneration.

Guided bone regeneration (GBR) is employed to encourage the formation of new bone in osseous defects by restricting the infiltration of soft tissues. While a variety of membranes have been evaluated for this surgical procedure, the non-resorbable material of choice is currently expanded polytetrafluoroethylene (e-PTFE). A new alkali-cellulose membrane produced by a biotechnological process has been developed as an alternative to e-PTFE for GBR. In this study, the biocompatibility of this novel alkali-cellulose membrane and e-PTFE was compared using tissue culture and an in vivo GBR model. In vitro both materials supported the attachment, migration and differentiation of osteoblast-like cells in culture for up to 3 weeks. The in vivo model was based upon full-thickness transcortical bone defects in the mandibular rami of Sprague-Dawley rats. The right rami were used as controls, contralateral defects being covered bucally and lingually with either e-PTFE or alkali-cellulose membranes. Pathological and histomorphometric analysis was undertaken at 4 and 10 weeks post-implantation. Bone regeneration associated with alkali-cellulose membranes was predominantly endochondral in type in contrast to e-PTFE which induced direct bone formation (intramembranous ossification). The amount of new bone formed in defects was similar for both types of membrane, but alkali-cellulose membranes induced significantly greater inflammatory response; characterized by lymphocytes, macrophages and multinucleated giant cells. Degradation and possible exposure of individual cellulose fibres may account for the poor performance of alkali-cellulose membranes in vivo. This animal and in vitro study indicates that when choosing a non-resorbable membrane for GBR, e-PTFE membranes are likely to perform better than those produced from alkali-cellulose.

Alveolar Bone Loss↗

Glass-ionomer cement: evaluation as an orbital implant.

BACKGROUND: To assess the potential of a porous glass-ionomer cement (GIC) as an alternative material for spherical orbital implants, the handling, side effects and rates of fibrovascular ingrowth of this material were compared with those of a synthetic hydroxyapatite (HA) implant. METHOD: Twenty-one GIC and 8 HA uncovered 14-mm spheres were implanted into the orbits of New Zealand albino rabbits. Postoperative reactions, animal's behaviour, weight increase and socket conditions were monitored. Light and electron microscopy of the exenterated orbits were performed 2, 3 and 6 months after primary insertion. RESULTS: Implanting of GIC was easier than HA. Postoperatively all animals did well. Three HA and 1 GIC implant caused conjunctival dehiscences, but no implant extrusion was observed. Histologically, both materials caused mild inflammation in the surrounding connective tissue capsule, decreasing with time. GIC implants proved to be not truly porous, with only peripheral pores partly occupied by relatively acellular collagenous connective tissue. Free glass particles were observed in both the connective tissue and giant cells, occupying the partly filled pore spaces. HA implants showed extensive ingrowth of vital host tissue from the beginning. CONCLUSIONS: Considering the clinical findings and the mild inflammation in the connective tissue capsule surrounding both materials, they would appear to be equally well tolerated at the implant site. The significantly different microstructure and the histological results make GIC, despite better handling, less suitable as an orbital implant.

Animals↗

Plasma copolymer surfaces of acrylic acid/1,7 octadiene: surface characterisation and the attachment of ROS 17/2.8 osteoblast-like cells.

The purpose of this study was: (a) to examine the effect of plasma-gas composition on plasma polymer oxygen/carbon (O/C) ratio, functional group composition and stability in water, and then (b) to examine cell attachment to surfaces containing different concentrations of O/C and functional groups. Oxygen-functionalised surfaces were deposited by means of the plasma copolymerisation of acrylic acid/1,7-octadiene. The use of a diluent hydrocarbon allowed the deposition of surfaces with a range of O/C concentrations. Plasma copolymer surfaces were characterised by X-ray photoelectron spectroscopy (XPS). Changes in functional group composition with % acrylic acid monomer and the non-dispersive and dispersive parts of the surface energy of these plasma copolymers were measured. The solubility of the plasma copolymers was assessed by means of XPS. The degree of attachment of ROS 17/2.8 osteoblast-like cells to plasma copolymer surfaces deemed to be 'stable' in aqueous medium was measured. Tissue culture polystyrene (TCPS) was included as a control. Attachment was found to be greatest to the plasma copolymer surface with an O/C of 0.11. This surface had a carboxylic acid concentration of ca. 3%. Attachment did not correlate with increased surface wettability (i.e. the non-dispersive component of the surface energy).

Acrylates↗

Glass-ionomers: bioactive implant materials.

Glass-ionomer cements (GICs) originally designed for use as dental materials have a number of advantages over acrylic bone cements. These include lack of exotherm during setting, absence of monomer and improved release of incorporated therapeutic agents; this has resulted in the development of GICs for biomedical applications. Major landmarks in this history are the formulation of defined-composition ionomer glasses and an improved understanding of the biological and material properties of GICs. Following implantation, GICs can form a stable integration with bone, and affect the growth and development of bone, both adjacent to their surface and systemically, through an ion release mechanism. The 'non-inert' nature of this group of materials is also demonstrated by their adverse effects on neural tissue. Successful clinical use of GICs, both as bone cements and as preformed implants for hard tissue replacement, have been reported in the fields of otologic surgery (Cochlear implant fixation, repair of the tympanic chain, eustation tube obliteration and as ear ossicles), and oral and reconstructive surgery. The use of GICs in situations where they will come into contact with nerves or neural tissue is contraindicated.

Animals↗

Dependence of in vitro biocompatibility of ionomeric cements on ion release.

The in vitro biocompatibility of a group of ionomeric cements (ICs) was evaluated with respect to their ion release properties. These ICs were made from a defined series of glasses with the general formula 1.5SiO2.0.5P2O5.Al2O3.(1.0-Z)CaO.0.75CaF2 where Z was the mole fraction (ranging from 0-0.1) of an alkali metal oxide, either sodium or potassium or a mixture of both. For these alkali metal ICs, the amount of sodium released was directly related to the sodium content of the constituent glass. Similarly, the amount of potassium released was directly related to the potassium content. There was no correlation between the aluminum content of the glass and the aluminum ion release. Increasing the monovalent cation concentration, however, produced ICs with increased fluoride release. The biocompatibility of the ICs, as assessed by in vitro cell growth and viability measurements, was inversely proportional to aluminum ion release. Fluoride ion release, although important in terms of in vitro biocompatibility, would appear to be less important than aluminum ion release in determining the overall biocompatibility of the ICs studied.

Journal Article↗

Role of exchanged ions in the integration of ionomeric (glass polyalkenoate) bone substitutes.

Ionomeric (glass polyalkenoate) implants are synthetic materials which can be used for repairing bone defects. It has been suggested that ions are leached from these implants during healing and that they influence cellular activity in the surrounding tissues. Morphological, immunohistochemical and microanalytical techniques were used to compare the osteogenic capacity of implants which eluted aluminium ions with implants which did not elute aluminium ions. The extracellular matrix molecules fibronectin and tenascin were located upon the surface of both implanted materials. Thick seams of lamellar bone were apposed to implants containing labile aluminium ions, but the bone was poorly mineralized. At the same time, transient increases were apparent in osteoblast activity on periosteal and endosteal surfaces and in chondrocyte activity in the growth plate and articular cartilages. In contrast, small amounts of mineralized lamellar bone were apposed to substituted implants (without aluminium) and the growth plate and articular cartilages remained normal in thickness and morphology. These results suggest that exchanged ions can influence the amount and quality of bone apposed to the implant. They also suggest that the effect of the ions depends upon their concentration and the state of differentiation of osteogenic cells.

Aluminum↗

The response of cultured bone cells to resorbable polyglycolic acid and silicone membranes for use in orbital floor fracture repair.

Two membranes intended for use in repairing fractures of the orbital floor--reinforced silicone and biodegradable polyglycolic acid (PGA)--were evaluated in vitro using a rat bone cell culture model. After two weeks in culture, cells had colonised the surface of both materials. Bone cells penetrated the weave of the PGA membrane after three weeks in culture, forming a calcified collagenous bone-like tissue within the weave of the PGA at the same time as there was evidence of resorption of the PGA. In contrast, cells could easily be dislodged from the surface of the reinforced silicone membrane and there was less evidence of mineralised extra cellular matrix production. The production of a bone-like tissue within the weave of the PGA membrane supported previous reports of osteoconductive activity of this material.

Animals↗

X-ray microanalytical detection of iron in pigmentation of oral mucosa.

A patient was referred to the Charles Clifford Dental Hospital with a grey metallic pigmentation of the hard palate. Conventional histopathological examination was inconclusive, suggesting the presence of either an ephelis (freckle) or pigmentation resulting from a stainless steel upper denture. Material from the pathological specimen was dewaxed and reembedded in Spurr's resin. Examination in the TEM revealed electron dense deposits in the cytoplasm of macrophages. Energy dispersive X-ray microanalysis demonstrated that these inclusions contained iron. The results suggested that the iron was in a form similar to haemosiderin and had arisen from the steel denture.

Dentures↗