Estimation of hydroxyl free radical levels in vivo based on liquid chromatography with electrochemical detection.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to I N Acworth.
Explore the source record for details and available documents.
Two simple modifications to a commercially available thin layer electrochemical detector cell permitted the attainment of ultra-low detection levels of two neurotransmitter catecholamines. An ESA model 5041 analytical cell was modified with a glassy carbon embedded ceramic composite electrode to allow the use of a thin 12 microm gasket. Also a capillary HPLC column was connected directly to the detector cell using a 30 microm i.d. fused silica capillary. These modifications permitted the extensive redox cycling of the electrochemically reversible catecholamines. The ensuing amplified analytical signal allowed the detector cell to achieve efficiencies of 1300%. This resulted in a mass limit of detection of 4 fg and a concentration limit of detection of 116 pM for dopamine with an S/N of 3.
The study of phytoestrogens in food sources and their metabolism, effects, and mechanism of action in animals requires very selective and often sensitive analytical techniques. We have applied coulometric array detection, which uses a series of flow-through electrochemical sensors each providing 100% electrolytic efficiency, for measurement of a variety of phytochemicals in complex matrices. Recent work has involved the resolution of coumestrol (COM), daidzein (DE), daidzin (DI), diethylstilbestrol (DES), enterodiol (ED), enterolactone (EL), equol (EQ), estradiol (E2), estriol (E3), estrone (E), genistein (GE), and quercetin (QE). Binary gradient reversed-phase (C18) chromatography was used with a sodium acetate buffer (pH 4.8)-methanol-acetonitrile solvent system. Eight coulometric sensors were set at 260, 320, 380, 440, 500, 560, 620, and 680 mV (vs Pd reference). Compounds were resolved in 30 min via both their oxidation/reduction characteristics and chromatographic behavior. Respective maximal oxidation potentials (mV) were: COM = 380; DE = 500; DI = 620; DES = 440; ED = 620; EL = 620; EQ = 560; E2 = 560; E3 = 560; E1 = 560; GE = 500; and QE = 260 with limits of detection of 5-50 pg. Uterine tissue homogenates (30 mg/ml in Tris-EDTA) and plasma from Sprague-Dawley rats sacrificed 1 hr after sc injection with either vehicle, dimethylsulfoxide, 10 microg DES, or 1.0 mg EQ were analyzed before and after enzymatic hydrolysis with beta-glucuronidase/sulfatase. Urine samples from humans receiving a Boston-area diet with or without soy protein isolate supplements were also analyzed. Ethanol extracts were evaporated and reconstituted in 20% methanol before HPLC analysis. DE, ED, EL, EQ, and GE were determined in urine with less than 5% (R.S.D.) intraassay imprecision and 85%-102% recovery. Levels (ng/ml) of GE (1.8), QE (11.2), and EQ (1.7) were found in control plasma before hydrolysis and GE (293), QE (183), and EQ (22) after hydrolysis. Higher concentrations, corresponding to sc injection, in free and total EQ were found in both tissue and plasma.
Free radical damage to proteins, lipids, DNA and RNA has been thought to play an important role in many diseases as well as the aging process. One free radical, the hydroxyl free radical (HFR), is extremely reactive and is difficult to measure directly. HFRs were quantified by measuring the hydroxylation products 2,3- and 2,5-dihydroxybenzoic acids (DHBAs) formed as a result of the reaction between HFR and systemically administered salicylate (SAL). DHBAs and SAL concentrations were determined using RP-HPLC with dual coulometric electrode detection. The method has limits of detection of 1 pg for the DHBAs and 100 pg for SAL (signal-to-noise ratio 3:1). A detailed interference study as well as analyte stability and linearity studies were performed. This method was used to determine basal ratios of DHBA/SAL in a variety of tissues and to study the effects of glutamatergic and dopaminergic drugs on DHBA/SAL ratios in brain region homogenates.
Explore the source record for details and available documents.
An improved high-performance liquid chromatographic (HPLC) method using electrochemical detection (ED) is described capable of routinely measuring the low levels of acetylcholine (ACh) typically found in rat brain microdialysis samples. Microdialysis was performed in the striatum of the urethane anesthetized rat using a 4-mm membrane length, high recovery (40% at 1.0 microliters/min; ambient conditions), loop-design probe perfused with an artificial cerebrospinal fluid (aCSF) solution containing physiologically normal calcium levels (1.2 mM). The HPLC method utilizes a polymeric stationary phase to resolve choline (Ch) from ACh. These analytes are then converted to hydrogen peroxide (H2O2) by a solid-phase reactor (containing immobilized choline oxidase and acetylcholinesterase enzymes). The H2O2 is detected amperometrically and quantitated on a platinum (Pt) working electrode (+300 mV; with a unique analytical cell featuring a solid-state palladium reference electrode). Two designs of the Pt working electrode were examined, differing only in the support material used (Kel-F or PEEK). The Kel-F/Pt electrode had a limit of detection (LOD) for both analytes of < 30 fmol per 10 microliters with a signal-to-noise ratio of 3:1. Striatal microdialysis perfusates were monitored for ACh and Ch over a 0-1000 nM range of neostigmine (NEO) in the CSF perfusion medium. Using the 4-mm probe, basal ACh and Ch levels were detected with a NEO level as low as 10 nM and were found to be 37 +/- 3 fmol and 22 +/- 1 pmol per 10 microliters (mean +/- S.E.M., n = 6 replicates) respectively. In similar experiments using 3-mm concentric probes comparable (lower) levels of ACh were found with the 50 and 1000 nM NEO doses (n = 4-21 animals). ACh could not be reliably quantitated when animals were perfused with the 10 nM dose of NEO (n = 4). The PEEK/Pt electrode had an improved LOD of < 20 fmol per 10 microliters due to a two- to three-fold decrease in the background noise component. Basal striatal levels of ACh in the absence of NEO approached the LOD and were found to be 15 +/- 2 fmol per 10 microliters; Ch was 5 +/- 1 pmol per 10 microliters (n = 2, mean of five basal samples). The analytical system requires very little maintenance; a simple electrochemical electrode cleaning step eliminates the need for routine polishing of the Pt electrode and the mobile phase is stable for up to one week.(ABSTRACT TRUNCATED AT 400 WORDS)
A high-performance liquid chromatographic method with coulometric array electrochemical detection is described for the simultaneous analysis of monoamines, their metabolites and o-phthalaldehyde (OPA)-derivatized amino acids. This method has been used to examine metabolite levels in both striatal tissue homogenates and striatal microdialysis perfusates. An aliquot of sample was initially analyzed for monoamines and metabolites by isocratic elution and electrochemical detection on a serial electrode array of eight coulometric flow-through graphite electrodes (0 to 490 mV; 70-mV increment). The remaining sample was derivatized pre-column with OPA-beta-mercaptoethanol and after column switching was analyzed for amino acids on a second isocratic system with electrochemical detection on four electrodes. Metabolites were then identified based on their retention time as well as electrochemical behavior across the arrays. The analysis, derivatization procedure, column switching, data reduction and peak identification were fully automated. The limit of detection for striatal tissue homogenates was approximately 1.38 ng/g wet weight for the monoamines and 8.25 ng/g wet weight for amino acids. The limit of detection for striatal perfusates was approximately 2.5 pg per 20-microliters sample for the monoamines and 15 pg per 20-microliters sample for the amino acids with analysis completed within 25 min making it ideal for microdialysis samples.
Analysis of phenolics and flavonoids in juice beverages using reversed-phase HPLC with coulometric array detection is described. Sixteen serial coulometric detectors were used for on-line resolution of co-eluting compounds and generation of voltammetric data. Within each class of compounds, oxidation potential corresponded to specific substitution patterns where: catechol < methoxycatechol < monohydroxyl < methoxyl. Twenty-seven standard compounds were resolved in a 45-min run. The limits of detection were in the low ng/ml range with a linear response range of at least three orders of magnitude. Intra-run retention time variation was < 1% (R.S.D.) and adjacent sensor response ratios varied by < 5% (R.S.D.). The utility of this technique in generating multivariate data for differentiation of juices and juice mixtures is shown.
We describe a procedure for the direct measurement of metanephrine (MN) and normetanephrine (NMN) in hydrolyzed urine, using HPLC with coulometric array detection. Acid-hydrolyzed samples were diluted and filtered before separation by isocratic reversed-phase ion-pair chromatography. Eight serial coulometric sensors, set at incrementally increasing anodic potentials, were used to screen lower-oxidizing interferences and provide stepwise oxidation of the metanephrines. Voltammetric behavior across three adjacent sensors was used to assess resolution and aid in peak identification. Values obtained in commercial controls were consistently within the specified target range. Variability, expressed as CV, was 5.45-9.22% between runs and 1.60-4.52% within-run for both compounds. The limit of detection was 2.6 micrograms/L for MN and 2.8 micrograms/L for NMN, with a linear response to 15.0 mg/L for both analytes. Results from patients' samples correlated well with those by a method involving dual ion-exchange extraction (r = 0.963, n = 82 for MN; r = 0.9768, n = 83 for NMN). This procedure provided high selectivity and objective peak purity information while greatly simplifying sample preparation.
We examined the effects of systemically administered thyrotropin-releasing hormone (TRH) on the release of dopamine (DA), as assessed by brain microdialysis within the corpus striatum of anesthetized rats. A single dose (10 micrograms i.v.) elevated DA levels in brain extracellular fluid (ECF) by 240% above baseline levels after 150 min. Systemic tyrosine ([TME] 20 mg/kg i.v.) also increased DA release (by 190% after 150 min), while combined treatment with both agents was associated with significant potentiation of the DA response (to 640% after 150 min). None of the treatments significantly altered striatal tissue levels of DA or its metabolites. A large dose of TRH (50 micrograms i.v.) significantly increased DA release (by 1150%) whether or not animals had received an active or denatured prolactin (PRL) antiserum prior to the experiment, suggesting that the TRH effect is not mediated by PRL. Although TRH is rapidly metabolized in plasma and penetrates the blood-brain barrier only poorly, our results suggest that even relatively small doses of the hormone can affect striatal dopaminergic neurotransmission.
Published evidence suggests a role for dopaminergic (DA) brain pathways in feeding-associated behaviors. Using the novel technique of brain microdialysis of striatal extracellular fluid (ECF) as an index of DA release, Church et al. described increases in levels of DA when animals had limited access to pellets, but not with free access. Dopamine release from the nucleus accumbens did increase with free access to pellets post starvation or after food reward. We used permanently implanted microdialysis probes to measure ECF levels of DA, DOPAC, HVA, and large neutral amino acids (LNAA) for up to 72 hours after implantation among rats experiencing different dietary regimens.
Intracerebral microdialysis was used to monitor dopamine release in rat striatal extracellular fluid following the intraperitoneal administration of dopamine's precursor amino acid, L-tyrosine. Dopamine concentrations in dialysates increased transiently after tyrosine (50-100 mg/kg) administration. Pretreatment with haloperidol or the partial lesioning of nigrostriatal neurons enhanced the effect of tyrosine on dopamine release, and haloperidol also prolonged this effect. These data suggest that nigrostriatal dopaminergic neurons are responsive to changes in precursor availability under basal conditions, but that receptor-mediated feedback mechanisms limit the magnitude and duration of this effect.
We used intracerebral dialysis to monitor extracellular levels of dopamine and its major metabolites dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) in rat striatum. Levels of these compounds were determined after intraperitoneal administration of phenylalanine (200, 500 and 1000 mg/kg). A dose of 200 mg/kg phenylalanine increased basal dopamine release by 59%, peaking at 75 min. There was no change in basal dopamine release after the 500 mg dose, whereas the 1000 mg/kg dose significantly reduced (26%) dopamine release. No significant changes were observed in the concentrations of DOPAC and HVA with any of the treatments, indicating that changes in brain phenylalanine and tyrosine levels may selectively affect production of the dopamine molecules that are preferentially released into synapses.
Intracerebral dialysis was used to monitor extracellular fluid from rat striatum and nucleus accumbens following the intraperitoneal administration of tyrosine. Dopamine concentrations in dialysates from both the striatum and the nucleus accumbens increased significantly in response to the tyrosine. The magnitude of the tyrosine effect was greater in the nucleus accumbens than in the striatum. Hence, mesolimbic dopaminergic neurons may be especially responsive to precursor availability.
Tyrosine administration elevates striatal levels of dopamine metabolites in animals given treatments that accelerate nigrostriatal firing, but not in untreated rats. We examined the possibility that the amino acid might actually enhance dopamine release in untreated animals, but that the technique of measuring striatal dopamine metabolism was too insensitive to demonstrate such an effect. Dopamine release was assessed directly, using brain microdialysis of striatal extracellular fluid. Tyrosine administration (50-200 mg/kg IP) did indeed cause a dose related increase in extracellular fluid dopamine levels with minor elevations in levels of DOPAC and HVA, its major metabolites, which were not dose-related. The rise in dopamine was short-lived, suggesting that receptor-mediated feedback mechanisms responded to the increased dopamine release by diminishing neuronal firing or sensitivity to tyrosine. These observations indicate that measurement of changes in striatal DOPAC and HVA, if negative, need not rule out increases in nigrostriatal dopamine release.