PubMed Health⌕ Search

Biomedical subjects

I P Panidis

Publications and source records attributed to I P Panidis.

At least 19 recordsLinked to original sources

Effect of percutaneous balloon valvuloplasty on pulmonary hypertension in mitral stenosis.

Percutaneous mitral balloon valvuloplasty (PMBV) has been useful in decreasing mitral valve obstruction in mitral stenosis; however, the long-term effects of valvuloplasty on pulmonary artery pressure have not been extensively studied. Thirty-three patients underwent PMBV in our institution between January 1988 and December 1991. There were significant reductions in peak (19 +/- 1 to 12 +/- 1 mm Hg) and mean (10 +/- 0.7 to 6 +/- 0.4 mm Hg) mitral valve gradients estimated by Doppler techniques immediately after PMBV. The mitral valve area, as assessed by the pressure half-time method, increased from 1.06 +/- 0.05 to 1.98 +/- 0.08 cm2 (p < 0.001) after the procedure and remained significantly greater (1.68 +/- 0.11 cm2) at 17 +/- 2 months. Right ventricular systolic pressure (RVSP) was estimated in patients with tricuspid regurgitation (TR) using the modified Bernoulli equation. There was a good correlation between Doppler and catheterization for RVSP (r = 0.83 pre valvuloplasty; r = 0.87 post valvuloplasty). Right ventricular systolic pressure by Doppler was 56 +/- 4 mm Hg before valvuloplasty and 48 +/- 4 mm Hg immediately afterwards (p < 0.001). Nine patients had TR on follow-up Doppler studies with an estimated RVSP of 53 +/- 9 mm Hg (p = NS compared with pre- and post-valvuloplasty values). Six of these nine patients had moderate or severe mitral regurgitation (MR), compared with one patient without TR at follow-up (p < 0.05). There appears to be a good correlation between the RVSP determined by Doppler and measured at catheterization.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Dynamic changes in left ventricular outflow tract flow velocities after amyl nitrite inhalation in hypertrophic cardiomyopathy.

Doppler echocardiography was performed in 21 patients with hypertrophic cardiomyopathy (HC), in nine patients with no evidence of left ventricular (LV) hypertrophy by two-dimensional echocardiography, and in five patients with systemic hypertension and concentric LV hypertrophy. The LV outflow tract (LVOT) peak velocity was recorded by continuous wave Doppler technique at rest and after amyl nitrite inhalation. The LVOT pressure gradient was calculated by the modified Bernoulli equation. A significant increase in heart rate and a drop in systolic blood pressure were observed in all patients after amyl nitrite inhalation; no adverse effects were encountered. The peak LVOT velocity and pressure gradient increased significantly after provocation in all patients, but the increase was much more pronounced in patients with HC (peak LVOT velocity increased from 2.2 +/- 0.8 to 4.3 +/- 1.0 m/sec and peak gradient increased from 22 +/- 17 to 78 +/- 36 mm Hg). The Doppler spectral signal in patients with HC demonstrated a characteristic contour, with peak velocity occurring in late systole. However, the observed increase in LVOT peak velocity was not statistically different between treated (with beta-blockers and calcium blockers) and untreated patients with HC. We conclude that LVOT peak velocity and pressure gradients in patients with HC can be readily assessed by Doppler echocardiography both at rest and after amyl nitrite inhalation. The dynamic changes in LVOT velocity induced by this provocation have certain characteristic features in obstructive HC but appear to be independent of the medical regimen used, at least in the dosages tested in our study.

Administration, Inhalation↗

Hemodynamic effects of octreotide in patients with autonomic neuropathy.

BACKGROUND: The somatostatin analogue, ectrootide, is being used to treat postprandial hypotension in patients with autonomic neuropathy. Although the therapeutic effect of the drug is presumably secondary to a splanchnic vasoconstrictor action, its effect on splanchnic hemodynamics has never been characterized in patients with autonomic neuropathy. Moreover, it is unknown whether octreotide acts on other vascular beds in this group of patients or whether it affects cardiac output. We, therefore, measured splanchnic, forearm, and systemic vascular resistance and cardiac output before and after administering octreotide (0.4 microgram/kg s.c.) to patients with idiopathic autonomic neuropathy and diabetic autonomic neuropathy. METHODS AND RESULTS: Splanchnic blood flow was determined from the clearance of indocyanine green in seven patients. We observed that octreotide decreased splanchnic blood flow (from 850 +/- 77 to 664 +/- 48 ml/min, p less than 0.005), increased mean blood pressure (from 97 +/- 6 to 115 +/- 3 mm Hg, p less than 0.005), and increased splanchnic vascular resistance (from 0.118 +/- 0.012 to 0.18 +/- 0.018 mm Hg/ml/min, p less than 0.005). Forearm blood flow was measured by plethysmography in 13 patients. Octreotide increased forearm vascular resistance in patients with idiopathic autonomic neuropathy (n = 8) from 19.1 +/- 1.0 to 27.2 +/- 3.8 mm Hg/ml/min/100 ml forearm volume (p less than 0.01) and from 25.2 +/- 3.9 to 41.0 +/- 6.8 mm Hg/ml/min/100 ml (p less than 0.01) in patients with diabetic autonomic neuropathy (n = 5). Cardiac output was measured by two-dimensional echocardiography. Octreotide administration increased cardiac output in five of six patients with idiopathic autonomic neuropathy (from 4.4 +/- 0.4 to 5.0 +/- 0.5 l/min, p less than 0.02) and five of five patients with diabetic autonomic neuropathy (from 3.8 +/- 0.4 to 5.1 +/- 0.4 l/min, p less than 0.02). Systemic vascular resistance increased in patients with idiopathic autonomic neuropathy from 21.2 +/- 2 to 24.9 +/- 2.6 (p less than 0.05) but did not change in patients with diabetic autonomic neuropathy. CONCLUSION: The pressor effect of octreotide in patients with autonomic neuropathy is associated with increased splanchnic and forearm vascular resistance and with increased cardiac output.

Adolescent↗

Hemodynamic consequences of left atrial myxomas as assessed by Doppler ultrasound.

Seven patients with left atrial (LA) myxoma who were studied by M-mode, two-dimensional, and Doppler echocardiography and who underwent surgical excision of the tumor are described. In six patients, the myxoma was attached to the lower interatrial septum and was protruding through the mitral valve (MV) during diastole. Significant MV obstruction (mean diastolic gradient of 16 mm Hg) was detected by Doppler in only one patient and was confirmed by hemodynamic studies; another patient had only a small gradient (peak 8 and mean 4 mm Hg). Mild mitral regurgitation (MR) was found preoperatively in four of five patients who underwent left ventriculography, but was not detected by Doppler. Postoperatively, however, five patients were found to have mild MR and one patient had moderate MR by Doppler. The use of Doppler echocardiography can provide important additional information regarding the hemodynamic consequences of LA myxomas.

Adult↗

Value and limitations of Doppler ultrasound in the evaluation of aortic stenosis: a statistical analysis of 70 consecutive patients.

Continuous-mode Doppler ultrasound and cardiac catheterization were performed within 1.4 +/- 2.0 days in 70 patients, aged 26 to 84 (mean 67 +/- 11) years, with suspected aortic stenosis. Optimal Doppler spectral display signal was recorded from the apical window in 43% of the patients, the second or third right parasternal area in 34%, and from the suprasternal notch view in 20% of the patients. Aortic valve gradients by Doppler ultrasound were calculated by the simplified Bernoulli equation: pressure gradient = 4X (velocity). There was an overall fair correlation between the peak gradient by Doppler technique and both the maximal instantaneous (r = 0.66) and peak-to-peak aortic pressure gradient (r = 0.68) obtained at catheterization and a good correlation (r = 0.75) between mean gradient by Doppler technique and catheterization. These correlation coefficients improved significantly in the last 51 patients as compared to the initial 19 patients of the study. Of the last 51 patients, correlation was better in those in normal sinus rhythm as compared to those in atrial fibrillation, and in patients with no or insignificant coexistent AR as compared to those with greater than or equal to 2+ AR. The age of the patient and the status of cardiac output did not significantly affect the accuracy of correlations. We conclude that measurements of aortic valve gradient by continuous-mode Doppler ultrasound may not correlate closely with those by catheterization when the experience with the Doppler technique is limited and when patients in atrial fibrillation or with significant coexistent AR are studied.

Adult↗

Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Doppler echocardiography was performed in 136 patients with a normally functioning prosthetic valve in the aortic (n = 59), mitral (n = 74) and tricuspid (n = 3) positions. These included patients with St. Jude (n = 82), Björk-Shiley (n = 18), Beall (n = 13), Starr-Edwards (n = 7) or tissue (n = 16) valves. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. The prosthetic valve orifice (PVO, in square centimeters), only in the mitral position, was calculated by the equation: PVO = 220/pressure half-time. In the aortic position, the St. Jude valve had a lower peak velocity (2.3 +/- 0.6 m/s, range 1.0 to 3.9), peak gradient (22 +/- 12 mm Hg, range 4 to 61) and mean gradient (12 +/- 7 mm Hg, range 2 to 32) than the other valves (p less than 0.05) when compared with Starr-Edwards). In the mitral position, the St. Jude valve had the largest orifice (3.0 +/- 0.6 cm2, range 1.8 to 5.0) (p less than 0.0001 compared with all other valves). Insignificant regurgitation was commonly found by pulsed mode Doppler technique in patients with a St. Jude or Björk-Shiley valve in the aortic or mitral position and in patients with a Starr-Edwards or tissue valve in the aortic position. In 17 other patients with a malfunctioning prosthesis (four St. Jude, two Björk-Shiley, four Beall and seven tissue valves) proven by cardiac catheterization, surgery or autopsy, Doppler echocardiography correctly identified the complication (significant regurgitation or obstruction) in all but 2 patients who had a Beall valve. It is concluded that 1) the St. Jude valve appears to have the most optimal hemodynamics; mild regurgitation can be detected by the Doppler technique in normally functioning St. Jude and Björk-Shiley valves in the aortic or mitral position and in Starr-Edwards and tissue valves in the aortic position, and 2) Doppler echocardiography is a useful method for the detection of prosthetic valve malfunction, especially when the St. Jude, Björk-Shiley and tissue valves are assessed.

Adolescent↗