PubMed Health⌕ Search

Biomedical subjects

I P Pappas

Publications and source records attributed to I P Pappas.

3 recordsLinked to original sources

A reliable gait phase detection system.

A new highly reliable gait phase detection system, which can be used in gait analysis applications and to control the gait cycle of a neuroprosthesis for walking, is described. The system was designed to detect in real-time the following gait phases: stance, heel-off, swing, and heel-strike. The gait phase detection system employed a gyroscope to measure the angular velocity of the foot and three force sensitive resistors to assess the forces exerted by the foot on the shoe sole during walking. A rule-based detection algorithm, which was running on a portable microprocessor board, processed the sensor signals. In the presented experimental study ten able body subjects and six subjects with impaired gait tested the device in both indoor and outdoor environments (0-25 degrees C). The subjects were asked to walk on flat and irregular surfaces, to step over small obstacles, to walk on inclined surfaces, and to ascend and descend stairs. Despite the significant variation in the individual walking styles the system achieved an overall detection reliability above 99% for both subject groups for the tasks involving walking on flat, irregular, and inclined surfaces. In the case of stair climbing and descending tasks the success rate of the system was above 99% for the able body subjects and above 96 % for the subjects with impaired gait. The experiments also showed that the gait phase detection system, unlike other similar devices, was insensitive to perturbations caused by nonwalking activities such as weight shifting between legs during standing, feet sliding, sitting down, and standing up.

Adult↗

Stability criterion for controlling standing in able-bodied subjects.

A new stability criterion that can be used to assess the standing condition of a subject from center of pressure (CoP) measurements is presented. This criterion can be applied, for example, to control a standing prosthesis, which should allow a paraplegic subject to stand up, sit down and stand safely without using hands for support. Experiments conducted with able-bodied subjects enabled us to establish a relationship between its stability and the subject's CoP position. Four CoP stability zones were identified: high preference, low preference, undesirable and unstable zones. The high preference zone is defined as the area where the CoP is found 99% of the time during quiet standing. The area where the CoP is found during the remaining 1% of the time is called the low preference zone. The undesirable zone is defined as the CoP area where the subject is forced to change posture in order to maintain balance, and the unstable zone is defined as the CoP area in which the subject is forced to step forward, backward or sideways to maintain stability. A general model of the proposed four stability zones was derived, which can be used to compute stability zones a priori for any subject and thus allows one to assess the subject's stability condition from the CoP measurements.

Adult↗