A survey into the respiratory effects of prolonged exposure to pulverised fuel ash.

Previous studies of respiratory disorders in workers exposed to pulverised fuel ash (PFA) have been confined to radiological effects that were found to be minimal. The present survey included 268 men (88% of the defined population) with a history of more than 10 years exposure to PFA in six power stations in the south east of England. Respiratory questionnaires with full occupational histories were obtained from all of these subjects, of whom 207 were actively employed and 61 had retired; 243 had lung function tests and 208 had chest x ray examinations. The men were grouped, using their occupational histories, into high, medium, and low exposure categories. Dust concentrations were obtained by personal sampling on a representative sample of men from the three exposure categories. Lung function tests showed that a modest effect on forced vital capacity, vital capacity, forced expiratory volume in one second, peak flow, and gas transfer (DCO) was associated with prolonged heavy exposure to PFA. The men with prolonged heavy exposure also showed higher prevalences of respiratory symptoms. No definite relation between exposure and x ray changes was established. The results of this cross sectional survey indicate that exposures to PFA should not exceed the limits recommended by the Health and Safety Executive for low toxicity dusts.

Adult↗

An evaluation of the vitalograph pulmonary monitor.

The Vitalograph pulmonary monitor has recently been altered by the manufactures to read in litres per minute. In 200 pairs of measurements comparing the monitor to the Wright peak flow meter (PFM) the mean difference between the instrument was 0.57 litres/min and there was a strong positive correlation (r = 0.92). The mean within subject coefficient of variation was 5.8% (range 2.6% to 10.7%). There was a statistical difference (P less than 0.05) in measurements obtained with different monitors but in practical terms this difference was small. The monitor is pocket-sized and light and is therefore suitable for following changes in peak expiratory flow away from the physiology laboratory.

Evaluation Studies as Topic↗

An evaluation of the mini-Wright peak flow meter.

The mini-Wright peak flow meter (MPFM) has been evaluated, and the results obtained from it show a strong positive correlation (r=0.970) with the Wright's peak flow meter (PFM). MPFM measurements, however, were biased to be about 38 1/min higher than PFM measurements (95% confidence limits 31.01/min to 45.01/min). Between instrument variation was found (F--ratio 3.67 with 9 and 81 degrees of freedom: P less than 0.001). In practice this did not appreciably affect individual measurements greatly as 95% confidence limits on any individual measurements were increased from +/-24 1/min to +/-27 1/min. There was no significant day-to-day variability in measurements obtained with individual instruments. The MPFM is a pocket-sized, simple, cheap, and robust instrument for following changes in ventilatory function. In clinical trails and surveys, however, both the bias in favour of the MPFM compared to the PFM and inter-machine variation must be taken into account. As the manufacturers have altered the scale to remove the bias since this study was performed, it will be important to know whether the original or the modified meter is being used in future studies.

Evaluation Studies as Topic↗

Demeclocycline in the treatment of the syndrome of inappropriate secretion of antidiuretic hormone.

Fourteen patients with the syndrome of inappropriate secretion of antidiuretic hormone (SIADH) have been treated with demethylchlortetracycline (demeclocycline) 1200 mg daily. In 12 patients the underlying lesion was malignant. The serum sodium returned to normal (greater than 135 mmol/l) in all patients after a mean of 8.6 days (SD +/- 5.3 days). Blood urea rose significantly from the pretreatment level of 4.2 +/- 2.3 mmol/l to 10.1 +/- 5.1 mmol/l at ten days (P less than 0.001). The average maximum blood urea was 13.4 +/- 6.8 mmol/l. In four patients the urea rose above 20 mmol/l, and in two of these demecyocycline was discontinued because of thie rise. The azotaemia could be attributed to a combination of increased urea producation and a mild specific drug-induced nephrotoxicity. Discontinuation of demeclocycline in six patients led to a fall in serum sodium, in one case precipitously, and return of the urea towards normal levels. Demeclocycline appears therefore to be an effective maintenance treatment of SIADH, and the azotaemia that occurs is reversible and probably dose dependent.

Adult↗