Benefit of single setting rate responsive ventricular pacing compared with fixed rate demand pacing in elderly patients.

In order to assess the value of a simple, single setting rate response option to VVI pacing, 12 patients (mean age 75.1 +/- 6.2, range 62-83 years, seven males, five females) with symptomatic complete heart block were entered into a double-blind, randomized crossover trial of VVI versus VVIR (single setting rate responsive) pacing using Medtronic Activitrax pacemakers. Assessment was by time taken in seconds (sec) and Borg scale symptom score (6-20) for simple activities (standing from chair x 30; walking 800 meters; 52 steps on stairs [slow and fast pace], and incremental, noninclined maximal treadmill exercise), performed after a 4-week period with the patient in each pacing mode. Times were significantly improved in VVIR mode for standing from chair [mean +/- SD] (78.7 +/- 22.5 vs 70.7 +/- 19.5 sec; P less than 0.05), for 800 m walk (1032 +/- 80 vs 885 +/- 59 sec; P less than 0.05), fast ascent of stairs (29.5 +/- 7.7 vs 26.5 +/- 5.6 sec; P less than 0.02), and treadmill exercise (626.7 +/- 189.5 vs 741.0 +/- 170.2 sec, P less than 0.005) although no difference in time for slow stair ascent was demonstrated. Symptom scores were significantly less in VVIR for standing from chair (12.7 +/- 2.8 vs 10.3 +/- 1.8; P less than 0.01), 800 m walk (10.9 +/- 2.7 vs 9.0 +/- 2.4; P less than 0.01), slow ascent of stairs (11.6 +/- 2.1 vs 10.0 +/- 2.0; P less than 0.01), and fast ascent of stairs (13.0 +/- 2.0 vs 11.7 +/- 1.9; P less than 0.02) but unchanged for treadmill exercise.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

The Activitrax rate responsive pacemaker system.

Bipolar Medtronic Activitrax rate responsive pacemakers were implanted in 31 patients for ventricular (28) or atrial (3) pacing. Mean follow-up was 16 months (range 10 to 26). Twenty pacemakers were implanted after catheter ablation of the His bundle, 7 for sick sinus syndrome. 1 for atrioventricular block and 3 for sick sinus syndrome with atrioventricular block. A rate response value was selected that gave a pacing rate of about 100 pulses/min during walking. Of the 31 patients, all had 24-hour ambulatory electrocardiographic monitoring with diary, 11 walked a 20-minute circuit, including a flight of stairs, and 20 had a treadmill exercise test. In 9 patients the pacing rate could be compared with the underlying sinus rate during exercise and was seen to match it very closely. In 12 patients the pacing rate during car driving was found to be similar to the sinus rate of 5 volunteers under similar conditions (mean minimum and maximum rate was 80 and 99 pulses/min, respectively). No pacing-induced arrhythmias were seen during ambulatory electrocardiographic monitoring. At high pacing rates slightly irregular pacing intervals were sometimes observed, which was due to polarization sensing. Sporadically, 1 pacing interval shortened to the upper rate value, because of a known and now resolved timing anomaly. Neither anomaly was of clinical consequence and the first could be resolved by reprogramming.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult