[Periodogram analysis for signal and noise evaluation in roentgen video signals].

Movements of the heart, the large vessels and the gastrointestinal tract can be evaluated for diagnostic purposes using fluoroscopic video systems. A new means of quantitatively evaluating the signal and noise components of the video signal is described. The signal and noise power components are determined from the periodogram after prior Fourier analysis. Variance is reduced by averaging and keeping the measuring conditions constant. For measurements of signal transfer properties, a radiological phantom capable of producing sinusoidal movements of the edge of the object was developed. An analysis of the performance of the theoretically derived evaluation parameters was carried out at a fluoroscopic unit under clinical conditions. Periodogram analysis makes possible objective image quality evaluation in clinical motion studies and in the technical quality assurance of fluoroscopic video systems. The use of a compact PC-based video measuring system renders application both practical and easy.

Artifacts↗

[Results of animal experiments with videodensitometry in the assessment of gastrointestinal motility].

It is possible to register video-densitometrically the gastrointestinal motility visible in fluoroscopic image using a video-signal analyser. The influence of metoclopramide at the propulsive movement of the stomach wall of rats was checked in vivo. The propulsive gastric movement increased in case of small doses of metoclopramide, higher doses stopped the motility. The propulsive gastric movement is parallel to the evaluation of the stomach. Metoclopramide has only a mild influence on the contraction frequency. We found that videodensitometry is also a practical method for evaluation of local wall motility of an intestinal segment of a rabbit. The non-visible motion is recorded and evaluated by means of several physical parameters (frequency, moving velocity of waves). Videodensitometry does not supply information on the causes of motion; hence, a combination with other methods, i.e. the registration of the electromyogram (EMG), is useful. In this way the mechanical answer to EMG-changes is simple to quantify. The experiment with rabbits affords a proof regarding the practicability of the method for pharmaco-physiological investigations.

Animals↗

[Conventional roentgen functional diagnosis--videodensitometry. 4. Conventional roentgen videodensitometry exemplified with peri-cardiac vessels].

It is possible to record movement-parameters by means of roentgen videodensitometry of the great central vessels as well the pulmonary artery as the thoracic aorta visible in fluoroscopic image (provided by videorecorder). We could noninvasively measure pre-ejection periods (PEP) for the right heart (PEP f) as well for the left heart (PEP g) by synchronous electrocardiography for each cardiac action and for each examination process. It is important to form a quotient between PEP f and PEP g in the individual case. First findings in patients with cardiac septal defects (with and without right heart block and pulmonary hypertension) show characteristic quotients and figures of the curves. In cases with electrocardiographic left heart block the elongated PEP g can be stated in graduated form. Further investigations on the mechanic interaction between the right and left heart, especially in cases of disorders in the heart conduction system, might be of interest.

Absorptiometry, Photon↗

[Conventional roentgen functional diagnosis--videodensitometry. 1. Densitometric and topometric measurements of roentgen video images: technique and method of measuring].

It is possible to measure movements in the human body with the help of X-ray television systems. A great number of different techniques has been published in the scientific literature. They all based on only two principles with qualitative differences in signal acquisition. The densitometric and topometric measurements are assessed and compared. Neither the densitometric nor the topometric principle seems to be superior. To support the experimental work the videoanalyser VIANA MP was developed on the Ilmenau Institute of Technology.

Computer Systems↗

[Conventional roentgen functional diagnosis--videodensitometry. 2. Clinical imaging site for noninvasive diagnosis of organ motion].

By means of the described system it is possible to measure and as well analog as digital process the organ movement, needing a X-ray television system for flouroscopy and a videotape for continuously recording. Using the densitometric principle measurements of time and a quantitative form analysis of the curves are performed. After border recognition and using the topometric principle, the local organ motion can be evaluated. The levels of signal and noise in the measured curves are computed by a fourier transformation. In the field of functional cardiology the video signal is recorded and processed synchronously with the electrocardiogram.

Computer Systems↗

[Conventional roentgen functional diagnosis--videodensitometry. 3. Conventional roentgen videodensitometry exemplified by the heart].

It is possible to record movement parameters video densitometrically and synchronously by means of a video signal analysator at various points of the organ surface visible via fluoroscopic images (provided by videorecorder). Movement parameters of the heart surface were signed just in the same cardiac action by synchronous electrocardiography. There are some difficulties in this method according to evaluation with reference to laevocardiography in consequence of functional variety of the heart and the different exercise conditions. Small aneurysms of the cardiac apex were only seen when they were separated and located at the cardiac margin. Extended cardiac aneurysms were video densitometrically recorded as a paradoxical movement at the cardiac surface. A paradoxical movement was never seen with negative findings in laevocardiography.

Absorptiometry, Photon↗

[Serological diagnosis of cytomegalovirus-induced interstitial pneumonia in patients following bone marrow transplantation].

For diagnosis of the interstitial pneumonia conditioned by cytomegalovirus (CMV) an indirect immunofluorescence test was used to measure IgM and IgG antibodies to CMV in 369 serum specimens from 41 patients after bone marrow transplantation (BMT). An interstitial pneumonia conditioned by CMV was diagnosed in 5 patients either serological (4 patients) or by detection of cytomegaloviral infection typical inclusion bodies in lung cells (1 patient). The detection of antibodies to CMV for diagnosis of interstitial pneumonia conditioned by CMV is problematical in the phase immediately after BMT because bone marrow recipients are severely immunosuppressed by radiation and cytotoxic drugs received before transplantation. New method for detection of CMV-specific antigens are necessary.

Adolescent↗

[The diagnosis of functional epigastric syndrome].

The radiological examination of the stomach and the duodenum under functional aspects resulted in references of an irritative stomach in patients with epigastric complaints without conceivable organic findings lasting for many years. On the basis of simultaneously established peculiarities in the behaviour and the social situation of the patients concerned the disturbance of kinetics demonstrated is realized with great probability and explained as pathological by the patient. The results of the examination may be points of influence for the therapy of such disturbances.

Adult↗

[Videodensitometry analysis of stomach wall motility--presentation of a new method].

The videodensitometry is a suitable method for recording the gastric wall motility. It provides biosignals amenable by computer. There are no special demands to any organic form or kind of contraction. The asymmetry of the stomach makes no difference, therefore. The hitherto usual manometry will not be superseded. Both methods complete themselves in an ingenious manner. The radiation exposure by videodensitometry can be diminished by modifying the system for image causation.

Absorptiometry, Photon↗

[Development of body weight in males of the Wurzen district 1961-1983].

In 1961, 1971 and 1983 additional medical parameters, among them body length and body weight, were established during the mass radiographies in the district of Wurzen. From the data of 7,670 males from the year 1983 for two 10-year age groups regression equations between body weight and body length were determined. The calculation of relative weights was performed on the basis of the optimum weights after Ott. The longitudinal comparison from 1961 to 1971 resulted in an increase of the number of persons with overweight by 17.7% during 10 years. The results of the examinations of the year 1983 showed that the trend to the increase of body weight continues in the male inhabitants of the district of Wurzen.

Adult↗

[Noninvasive roentgen diagnosis of right heart function in patients with recirculation disorders and chronic nonspecific lung changes].

The non-invasive x-ray functional diagnostic electroradiographic method at the large vessels near the heart may enrich the radiological preliminary diagnostics of recirculation abnormalities. In chronic unspecific pulmonary diseases it can characterize the load of the right heart. Our studies should serve as a pilot study for the in future possible, simply to be handled non-invasive video-densitometry of the vessels near the heart in the preliminary diagnostics of cardiovascular diseases.

Cardiac Output↗

[The value of computer tomography in the postoperative long-term surveillance of patients with a vascular prosthesis for aorta replacement].

Because of the possibility of life-threatening late complications by anastomotic aneurysms and the danger of their rupture, all patients in whom a coarctation of the aorta was resected and replaced by a vascular prosthesis must be followed up continuously for life. Their chest x-rays show-in addition to unequivocally normal or pathological findings-sometimes questionable variations of the aortic outline, which must be diagnosed definitely by further investigations. By means of computerized tomography, the suspicion of an anastomotic aneurysm can either be refuted or confirmed in almost all cases. Thus, the invasive examination by aortography, which is desirable before operation of an aneurysm, may be omitted in the group of unsuspicious patients. Out of 198 patients, who received a vascular prosthesis for correction of an aortic coarctation in the time from 1960 to 1980, 27 were examined by computerized tomography because of irregular findings in their chest x-rays. In 6 patients the suspicion of an anastomotic aneurysm was confirmed and could be proved by aortography and reoperation. In 21 patients an aortography could be omitted because of its unsuspicious findings by computerized tomography.

Aorta, Thoracic↗

[Determination of the systolic time interval in normal subjects from electrokymographic studies of vessels near the heart].

By means of electrokymography curves of the motion of the vascular margin of the large vessels near the heart, aorta and pulmonary artery, may be recorded noninvasively. Since these curves of motion widely correspond to the central curves of the arterial pulse it is possible to state systolic time intervals separately for the right and left heart. Analogically to the presphygmic index after Rentsch with global evidence on the left-ventricular function of the heart these are possible for the outflow way of the right ventricle, also by formation of the quotient of the electrokymographically established STI. Comparisons between right-ventricular and left-ventricular STI and relations to the at the same time electrokymographically stated dynamic parameters of the heart wall are the result. In the present paper on the basis of electrokymographical investigations on 24 test persons with healthy heart the concerning the contents reasonable STI with relatively slight statistical distribution and their quotient are determined as starting-point to further investigations.

Aorta↗