PubMed Health⌕ Search

Biomedical subjects

I S Krull

Publications and source records attributed to I S Krull.

At least 37 records · Page 2Linked to original sources

General strategies and selection of derivatization reactions for liquid chromatography and capillary electrophoresis.

The general strategies, reasons and the different possibilities for the derivatization of biomedically important compounds are reviewed. Different approaches apply for small versus large analyte molecules, different advantages and disadvantages are visualized with pre- and post-column arrangements. Particular interest is focused upon solid-phase derivatization reagents.

Chromatography, High Pressure Liquid↗

Polymeric 6-aminoquinoline, an activated carbamate reagent for derivatization of amines and amino acids by high-performance liquid chromatography.

A new polymeric reagent containing the 6-aminoquinoline (6-AQ) tag was developed and applied for the off-line derivatization of amines and amino acids in high-performance liquid chromatography (HPLC). The synthesis and characterization of this polymeric reagent are described. An authentic external standard of a typical amine was synthesized and characterized for the determination of the derivatization efficiency. All amines had a derivatization efficiency higher than 50%; the derivatization of amino acids was performed under optimized phase-transfer catalysis reaction conditions. Derivatized amines and amino acids were separated under conventional reversed-phase conditions and determined by UV and FL detectors. To investigate the practical applications, this polymeric reagent was also used to derivatize protein hydrolysates.

Amines↗

Improved detection and derivatization in capillary electrophoresis.

Capillary electrophoresis is well known for its low mass detectabilities, but suffers from poor concentration detection limits. This review will discuss improvements in concentration detectability with an emphasis on derivatization methods. Sample concentration techniques and improved detector designs will also be discussed. Pre- and post-capillary derivatization methods for biofluid analytes such as amino acids, peptides, proteins, oligonucleotides, and oligosaccharides will be examined in detail.

Amino Acids↗

Stabilization of reactive species within polystyrene divinylbenzene polymer networks.

The effect of cross-linking, surface area, and porous nature of modified polystyrene-divinylbenzene (STY-DVB) reagents has been investigated. The supports were prepared via two techniques and modified to contain various chemical functionalities. These reagents were used in an on-line reactor for automated derivatization of amines in HPLC. The reproducibility of the response vs the physical nature of the porous support and the chemical functionality was determined. The ability to stabilize highly reactive acylating reagents toward high concentrations of aqueous base was found to be a complex interaction of pore size distribution, percent cross-linking, surface area, and absolute loading of the analytical reagent on the porous support.

Chromatography, High Pressure Liquid↗

Direct determination of adamantanamine in plasma and urine with automated solid phase derivatization.

A simple, highly sensitive and selective method is described for adamantanamine determination in plasma and urine by high-performance liquid chromatography with fluorescence detection. The method involved a simultaneous extraction and derivatization of biological fluids with a 9-fluoreneacetate (9-FA) solid-phase derivatization reagent. This approach eliminated tedious sample preparation steps and provided automatic derivatization with selective and efficient sample clean-up for direct injection of biological fluids. Derivatized adamantanamine was separated under conventional reversed-phase conditions and determined by fluorescence detection. The optimization and validation of the derivatization method with the 9-FA solid-phase reagent is described.

Acetates↗

Peptide mapping using EOF-driven capillary isoelectric focusing.

Capillary isoelectric focusing (CIEF) in uncoated and commercially available coated capillaries was applied to the separation of tryptic peptides from bovine and chicken cytochrome c. This is the first report of peptide mapping by CIEF. Before separation, the pIs of individual peptides expected to be formed during the digest were calculated, and then the separation pattern obtained was correlated with the calculated pIs. This correlation was reasonably good for some peptides, but not as good for others. However, differentiation of the two species digests was easily achieved based on the CIEF map. The major limitation of the method is the fact that uv detection at 280 nm must be employed, meaning that only tryptophan and tyrosine containing peptides will be detected, since the ampholytes used to generate the pH gradient absorb below 280 nm. Post-column derivatization of the peptides is one solution to this problem. Migration time reproducibility was on the order of 2%, and run times were less than 20 min for the entire pH gradient range in the uncoated capillary. In the coated capillary, superior resolution was obtained at the expense of longer run times.

Amino Acid Sequence↗

Determination of on-line differential refractive index and molecular weight via gradient HPLC interfaced with low-angle laser light scattering, ultraviolet, and refractive index detection.

Gradient ion-exchange chromatography (IEC) was interfaced with a low-angle laser light scattering photometer (LALLS) and ultraviolet (UV) and refractive index (RI) detectors connected in series for on-line determination of the differential refractive index (dn/dc) of proteins and eventually their molecular weights (Mw's). Interfacing of gradient HPLC with a RI detector was made possible by using two isorefractive buffers, which helped generate stable baselines for the LALLS and RI detectors. An optically modified, laser based RI detector was used for determination of dn/dc. On-line determinations of dn/dc required smaller amounts of sample compared to off-line determinations (3-4 mg vs 200 mg). Also, dn/dc could be measured by making one repetitive injection of the sample, if the molar absorptivity of the sample was known. dn/dc values determined on-line were in close agreement with those determined off-line. Additionally, percent recovery of the sample was calculated on-line, and this provided true concentration detected at the UV detector, which was then used for determination of Mw.

Chromatography, High Pressure Liquid↗

Determination of peptide 520 in human plasma using post-column photolysis with electrochemical detection in liquid chromatography.

A simple LC method for the determination of peptide 520 in human plasma was developed. Based on micellar chromatography, sodium octyl sulphate (SOS) was added into the mobile phase in order to separate the peptide from human plasma components. The procedure was fast and sensitive for the determination of the peptide in untreated human plasma. The electrochemical (EC) detection limit for peptide 520 in human plasma was 0.5 microgram ml-1. Linearity of the calibration plot for peptide 520 in human plasma was 0.999. This approach represents a direct injection technique for the potential detection and analysis of numerous peptides in biofluids, besides just plasma, with absolute quantification.

Chromatography, Liquid↗

Immobilized isocyanates for derivatization of amines for chiral recognition in liquid chromatography with UV detection.

Solid-phase derivatization reagents containing a 3,5-dinitrophenyl moiety for the derivatization of amines are described. The reagents are useful for Pirkle-type recognition of stereochemical composition of amines and related nucleophiles. The ability to stabilize 3,5-dinitrophenylisocyanate by covalent immobilization on a polymeric support varied greatly with the support chosen. The kinetics of the activated dinitrophenylcarbamate and the use of this reagent for enhanced recognition of optical purity is shown and compared to previous findings with a similar polymeric activated ester.

Alcohols↗

9-Fluoreneacetyl-tagged, solid-phase reagent for derivatization in direct plasma injection.

We describe here a resin-based derivatization reagent, containing a 9-fluoreneacetyl tag on a controlled-pore substrate, for direct injection analysis of amphetamine in plasma. On-line, pre-column derivatization was performed by direction injection of diluted plasma sample into an sodium dodecyl sulfate-containing mobile phase. Amphetamine was trapped in the hydrophobic derivatization column and derivatized at elevated temperature by the activated solid-phase reagent. The derivatized 9-fluoreneacetyl amphetamide was separated by reversed-phase high-performance liquid chromatography with a step gradient and determined by fluorescence detection. The synthesis scheme, characterization, and optimization of the derivatization conditions for the solid-phase reagent are described. The method was evaluated by reproducibility tests and single blind spiking analysis. This solid-phase reagent combined with a surfactant containing mobile phase provided a sensitive and simple procedure for on-line derivatization in direct injection analysis of biological fluids.

Amphetamine↗

Capillary electrophoresis: the promise and the practice.

The field of capillary electrophoresis has undergone rapid development over the past 10 years. Many advances have been made, but there are still some problems that must be addressed before the technique can reach its full potential.

Amino Acid Sequence↗

Interfacing gradient elution ion-exchange chromatography and low-angle laser light-scattering photometry for analysis of proteins.

Molecular weights (MWs) of different proteins were determined by interfacing gradient elution ion-exchange chromatography and low-angle laser light-scattering photometry (IEC-LALLS). A high-performance strong cation-exchange column was used to elute proteins using fast (5 min) and conventional (15-30 min) gradients. The eluted proteins were characterized on-line by determining their MWs using LALLS. The specific refractive index (RI) increment (dn/dc) and the RI of the solvent used over the gradient range were determined off-line and used to calculate the absolute weight-average MWs. Four proteins, ribonuclease A, alpha-chymotrypsinogen A, trypsinogen and beta-lactoglobulin A (beta-LACT) were studied. Accurate MWs were obtained for all the proteins using fast and conventional gradients, except for beta-LACT, which aggregated as a function of the gradient employed. The degree of aggregation of beta-LACT increased as the rapidity of the gradient was increased over a fixed gradient range. This study indicated that it is possible to separate and characterize proteins rapidly using IEC-LALLS.

Chromatography, Ion Exchange↗

Comparison of 9-fluorenylmethoxycarbonyl and 9-fluoreneacetyl-tagged silica-based derivatization reagents in high-performance liquid chromatography.

Two silica reagents based on a 4-hydroxy-3-nitrobenzoyl backbone were synthesized and characterized with 9-fluorenylmethoxycarbonyl (FMOC) and 9-fluoreneacetyl (FA) tags. These reagents were tested by derivatization of primary and secondary amines. Derivatization conditions such as temperature, time and triethylamine catalyst were tested. The FA-tagged silica reagent showed better performance than the FMOC-tagged silica reagent by a comparison of derivatization efficiencies, stabilities of reagents, and blank reagent interferences with derivatization. Finally, cadaverine and an aliphatic amine mixture were analysed using the FA-tagged reagent by pre-column, off-line derivatization and fluorescence detection.

Acetates↗

Electrochemical detection of proteins in high-performance liquid chromatography using on-line, postcolumn photolysis.

Direct detection of proteins in high-performance liquid chromatography electrochemistry (LCEC) is difficult. By using on-line, postcolumn photolysis, proteins now can be detected by LCEC at microgram per milliliter levels. The compatibilities of size exclusion chromatography (SEC), reversed-phase chromatography (RPC), ion-exchange chromatography (IEC), and hydrophobic interaction chromatography (HIC) with photolysis-electrochemical detection is described for proteins together with the analytical figures of merit. Inherent from the advantages of electrochemical detection, the method is sensitive and selective.

Chromatography, High Pressure Liquid↗

Use of Ce(IV) oxidizing agent for the derivatization of polycyclic aromatic hydrocarbons for liquid chromatography-electrochemical detection.

Polycyclic aromatic hydrocarbons (PAHs) were oxidized with Ce(IV), and the resulting quinones were determined by reductive-mode liquid chromatography-electrochemical detection. This oxidation is a rapid, automatable step, involving of Ce(IV) reagent to the PAH sample and cleaning up the derivative with C18 solid-phase extraction. Using a C18 analytical column and a 2-propanol-phosphate buffer as the mobile phase, detection limits were in the ppb range for naphthalene, phenanthrene and anthracene, with linearity over 3-5 orders of magnitude. Method validation was performed by addition of the PAHs to tap water and determining the levels by reference to a calibration curve. The three PAHs can be simultaneously derivatized and determined under the same chromatographic conditions. Analysis of a motor-oil sample is also shown.

Anthracenes↗

Quantitation of insulin injection by high-performance liquid chromatography and high-performance capillary electrophoresis.

High-performance capillary electrophoresis (HPCE) was evaluated as a potential technique for the regulatory analysis of commercial dosage forms of insulin. A comparison was made to a liquid chromatographic analysis presently being proposed as an official monograph in the United States Pharmacopeia. The salient points of this comparison were accuracy, precision and ease of use. Both authentic (i.e. single blind, spiked) samples and commercial pharmaceutical formulations (injections) were examined. Chromatographic analyses of both commercial formulations and authentic samples were characterized by good precision, with accuracy being supported by results from authentic (spiked) samples. Conventional HPCE (by which is meant a non-micellar electrolyte used with an uncoated, unmodified fused-silica capillary) achieved reasonable accuracy, but less than impressive precision, when applied to authentic samples. When used for commercial formulations, this type of HPCE did not produce a level of accuracy suitable for regulatory purposes, even with the use of an internal standard.

Animals↗

Determination of pituitary and recombinant human growth hormone molecular weights by modern high-performance liquid chromatography with low angle laser light scattering detection.

The determination of molecular weight for pituitary and recombinant human growth hormone (p-hGH/Crescormon and r-hGH/Protropin) has been performed. This has involved on-line coupling of size-exclusion chromatography (SEC) and gradient elution, reversed-phase high-performance liquid chromatography (RP-HPLC) with low-angle laser light scattering (LALLS) detection. A 5-microns, 300 A, Delta-bond octyl column was used. Traditional specific refractive index increment (dn/dc) and refractive index (n) measurements have been performed in order to derive absolute weight-average molecular weight (Mw) information for p-hGH and r-hGH. Known concentrations of each protein have been separated using reversed-phase gradients utilizing acetonitrile with on-line LALLS determination of excess Rayleigh scattering factors. Accurate Mw data has been obtained for both proteins under conventional RP-HPLC gradient elution conditions. SEC data of both hGHs were found to be concentration, mobile phase, and column dependent for the particular analyses. Both medium- and high-resolution SEC-LALLS studies were performed, and all of these determinations further confirmed our RP-HPLC results. On-line LALLs provides certain advantages in identifying aggregates that may be present, even in medium-resolution SEC, where incomplete resolution occurs. The on-line coupling of modern RP-HPLC for biopolymers with LALLS detection represents a major step forward in the ability of bioanalytical chemists to determine the nature (monomer versus higher-order aggregate) of such materials. Other classes of biopolymers should prove suitable for studies with the same RP-HPLC-LALLS-UV approaches.

Chromatography, Gel↗

Solid-phase reagent containing the 3,5-dinitrophenyl tag for the improved derivatization of chiral and achiral amines, amino alcohols and amino acids in high-performance liquid chromatography with ultraviolet detection.

A solid-phase reaction technique is described for improved derivatization of aliphatic amines, amino alcohols and amino acids. A polymeric activated ester is used for the immobilization of the 3,5-dinitrobenzoyl group, which can then be used for derivatizations of strong or weak nucleophiles, while avoiding solution-phase derivatization conditions. The reagent is easily prepared and can be regenerated after use to attain its original reactivity. The resulting chromatograms are free of system peaks due to excess derivatizing reagent, and sample handling is kept to a minimum. The reagent can be used in conjunction with both reversed- and normal-phase chromatography and can be used for off-line gas chromatographic or high-performance liquid chromatographic (HPLC) derivatizations. In addition, the reagent can be used on-line for derivatization in HPLC. Since the labelling reagent is a strong pi-acid, chiral substrates can be derivatized and separated on a Pirkle-type pi-donor column. The confirmation and quantitation of amphetamine in urine was accomplished using a polymer containing two labelling moieties, p-nitrobenzoyl and 3,5-dinitrobenzoyl. The derivatization and separation of chiral and achiral amines, amino alcohols and amino acids is described.

Alcohols↗