Publications and source records attributed to I Schnittger.

At least 19 recordsLinked to original sources

Rapid assessment of cardiac anatomy and function with a new hand-carried ultrasound device (OptiGo): a comparison with standard echocardiography.

AIMS: The aim of this study was to evaluate image quality and accuracy of a new hand-carried ultrasound device, OptiGo (Agilent Technologies) when compared to standard echocardiography in the setting of a focused examination in the assessment of cardiac anatomy and function. METHODS AND RESULTS: One-hundred and twenty-one patients were prospectively enrolled. Image quality and accuracy in assessment of chamber sizes, left ventricular (LV) wall thickness and contractility, right ventricular (RV) function, mitral and aortic leaflet thickening, mitral annular calcification, pericardial effusion and valvular regurgitation were assessed. Two-dimensional (2D) findings were graded on a four-point scale, except for LV function (six-point) and valvular leaflet opening (two-point). Colour Doppler assessment of valvular regurgitation was graded on a seven-point scale. A one-point difference was considered minor; a two or more point difference was considered major. There was no statistically significant difference in image quality between the two devices. For 2D data, the number of total (minor and major) differences between the hand-carried and standard echocardiograph examinations was significantly greater than the inter-observer variability (14.3% vs 10.7%, P< 0.05), however, major differences alone were not statistically different. For the colour Doppler assessment of regurgitation there was a significant difference between the devices for total (minor and major) differences, (40.0% vs 31.8%,P < 0.007) however, the number of major differences is explained by inter-observer variability. CONCLUSIONS: Image quality and diagnostic accuracy of the hand-carried device, OptiGo, was adequate for the purpose of performing a focused assessment of a limited number of 2D and Doppler parameters for the evaluation of cardiac anatomy and function.

Adult↗

Contrast echocardiography is superior to tissue harmonics for assessment of left ventricular function in mechanically ventilated patients.

BACKGROUND: Assessment of left ventricular function by echocardiography is frequently challenging in mechanically ventilated patients. We evaluated the potential value of contrast-enhanced imaging and tissue harmonic imaging over standard fundamental imaging for endocardial border detection (EBD) in these patients. METHODS AND RESULTS: Fifty patients underwent standard transthoracic 2D echocardiography and were imaged in fundamental and tissue harmonic modes and subsequently with intravenous contrast (Optison). Two echocardiographers reviewed all studies for ease of visualization of endocardial border segments and scoring of wall motion. EBD for each wall segment was graded from 1 to 4 (1 = excellent EBD). Wall motion was scored by a standard 16-segment model and 1 to 5 scale. Studies were categorized as nondiagnostic if 4 of 6 segments in the apical 4-chamber view were either poorly seen or not seen (EBD score 3 or 4). Quantification of ejection fraction was independently performed offline. Visualization of 68% of all segments improved with contrast echocardiography versus 17% improvement with tissue harmonics compared with fundamental mode. Significant improvement (poor/not seen to good/excellent) occurred in 60% of segments with contrast echocardiography versus 18% with tissue harmonics. A total of 850 segments were deemed poor/not seen, 78% of which improved to good/excellent with contrast echocardiography versus 23% with tissue harmonics. Interobserver agreement on EBD was 64% to 70%. Conversion of nondiagnostic to diagnostic studies occurred in 85% of patients with contrast echocardiography versus 15% of patients with tissue harmonics. Scoring of wall motion with fundamental mode, tissue harmonics, and contrast echocardiography was possible in 61%, 74%, and 95% of individual segments, respectively (P <.001). Wall motion scoring was altered in 17% of segments with contrast echocardiography and in 8% with tissue harmonics. Interobserver agreement on wall motion scoring was 84% to 88%. Contrast echocardiography permitted measurement of ejection fraction 45% (P =.003) more often over fundamental mode versus a 27% (P =.09) increase with tissue harmonics. CONCLUSIONS: Contrast echocardiography is superior to tissue harmonic imaging for EBD, wall motion scoring, and quantification of ejection fraction in mechanically ventilated patients.

Adult↗

Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool.

This study sought to validate a new noninvasive method to measure cardiac output, in the clinical setting, using color Doppler flow integration. This method, the automatic cardiac output measurement (ACOM), using color Doppler was recently developed and validated in vitro. ACOM was performed at the aortic valve and in the left ventricular outflow tract in 106 subjects (60 men, mean age 52 +/- 18) and compared with the echocardiographic pulsed-wave Doppler and a 2-D volume method. In 14 patients the noninvasive methods were correlated with the thermodilution technique. ACOM was feasible in 101 subjects (95%). The correlation factor between the values obtained with ACOM in the apical 5-chamber view and apical long-axis view was 0.75 at the aortic valve and 0.74 in the left ventricular outflow tract. Interoperator variability for ACOM in the apical 5-chamber and apical long-axis views were 0.93 and 0.75, respectively. The best comparison of ACOM with the pulsed-wave echo-Doppler technique occurred in the apical long-axis view (n = 79, r = 0.62), whereas the correlation with the 2-D volume method was poor. The most favorable comparison of ACOM with the thermodilution technique (n = 14) was also obtained in the apical long-axis view (5.408 +/- 1.72 vs. 3.356 +/- 1.281/min. [mean +/- SD], r = 0.71). Assuming the thermodilution technique as 'gold standard', the pulsed-wave echo-Doppler technique showed a better correlation (5.408 +/- 1.72 vs. 4.664 +/- 1.281/min., r = 0.84). ACOM is a useful, reproducible, noninvasive tool for rapid automated measurements of cardiac output. There is, however, an underestimation when compared with the pulsed-wave Doppler echocardiography and the thermodilution techniques. Good 2-D echocardiographic images, adequate color filling of the outflow tract and high frame rates are prerequisites for accurate values. Further refinements of this new technique are needed to enhance its clinical value in the future.

Cardiac Output↗

Native tissue harmonic imaging improves endocardial border definition and visualization of cardiac structures.

BACKGROUND: The purpose of this study was to examine the impact of native tissue harmonic imaging on endocardial border definition, wall motion scoring, and visualization of intracardiac structures. METHODS AND RESULTS: For wall motion analysis, 60 consecutive patients underwent standard transthoracic echocardiograms in both harmonic and fundamental modes. Three experienced echocardiographers reviewed each echocardiogram. Endocardial border definition for each wall segment was graded from 1 to 4 (1 = excellent endocardial definition). Wall motion was scored by using a standard 16-segment model and 1 to 5 scale. For visualization of cardiac structures, 50 consecutive patients were studied. Two experienced interpreters reviewed each echocardiogram for both normal and abnormal structures by using the following scoring scale: (1) harmonic is much better than fundamental, (2) harmonic is slightly better than fundamental, (3) harmonic and fundamental are equivalent, (4) fundamental is slightly better than harmonic, and (5) fundamental is much better than harmonic. Visualization of 64% (95% confidence interval [CI] 0.61 to 0.66) of all segments improved in harmonic mode, with 26% (95% CI 0.24 to 0.29) improving from poor/not seen to good/excellent. Of 444 segments deemed poor/not seen, visualization of 312 (70%) (95% CI 0.66 to 0.75) improved to good/excellent with harmonic mode. Of these 312 segments, 55% comprised the lateral and anterior walls on apical views. Interobserver agreement on endocardial border definition was 82% to 86%. Scoring of wall motion was altered in 171 of 1075 (16%) of segments by harmonic mode. This was significantly greater than the interobserver disagreement, which was only 10% (p<0.002). Mitral valve chordae and papillary muscles were visualized slightly/much better with harmonic mode in 40 of 50 echocardiograms. Left atrial boundaries were seen slightly/much better in harmonic mode in 29 of 50 studies. Abnormal structures were seen slightly/much better in harmonic mode in 12 of 14 cases. CONCLUSIONS: Native tissue harmonic imaging has significant impact on endocardial border definition and wall motion scoring and improves the visualization of both normal and abnormal cardiac structures.

Cardiomyopathies↗

Accuracy of biplane and multiplane transesophageal echocardiography in diagnosis of typical acute aortic dissection and intramural hematoma.

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of biplane and multiplane transesophageal echocardiography in patients with suspected aortic dissection, including intramural hematoma. BACKGROUND: Transesophageal echocardiography is a useful technique for rapid bedside evaluation of patients with suspected acute aortic dissection. The sensitivity of transesophageal echocardiography is high, but the diagnostic accuracy of biplane and multiplane transesophageal echocardiography for dissection and intramural hematoma is less well defined. METHODS: We studied 112 consecutive patients at a major referral center who had undergone biplane or multiplane transesophageal echocardiography to identify aortic dissection. The presence, absence and type of aortic dissection (type A or B, typical dissection or intramural hematoma) were confirmed by operation or autopsy in 60 patients and by other imaging techniques in all. The accuracy of transesophageal echocardiography for ancillary findings of aortic dissection (intimal flap, fenestration and thrombosis) was assessed in the 60 patients with available surgical data. RESULTS: Of the 112 patients, aortic dissection was present in 49 (44%); 10 of these had intramural hematoma (5 with and 5 without involvement of the ascending aorta). Of the remaining 63 patients without dissection, 33 (29%) had aortic aneurysm and 30 (27%) had neither dissection nor aneurysm. The overall sensitivity and specificity of transesophageal echocardiography for the presence of dissection were 98% and 95%, respectively. The specificity for type A and type B dissection was 97% and 99%, respectively. The sensitivity and specificity for intramural hematoma was 90% and 99%, respectively. The accuracy of transesophageal echocardiography for diagnosis of acute significant aortic regurgitation and pericardial tamponade was 100%. CONCLUSIONS: Biplane and multiplane transesophageal echocardiography are highly accurate for prospective identification of the presence and site of aortic dissection, its ancillary findings and major complications in a large series of patients with varied aortic pathology. Intramural hematoma carries a high complication rate and should be treated identically with aortic dissection.

Acute Disease↗

Upper airway resistance syndrome, nocturnal blood pressure monitoring, and borderline hypertension.

Upper airway resistance syndrome (UARS) is a sleep-disordered breathing syndrome characterized by complaints of daytime fatigue and/or sleepiness, increased upper airway resistance during sleep, frequent transient arousals, and no significant hypoxemia. Of a population of 110 subjects (58 men) diagnosed as having UARS, we investigated acute systolic and diastolic BP changes seen during sleep in two different samples. First, six patients from the original subject pool were found to have untreated chronic borderline high BP, and were subjected to 48 h of continuous ambulatory BP monitoring before treatment and another 48 h of BP monitoring 1 month after the start of nasal-continuous positive airway pressure (N-CPAP) treatment. Five of six subjects used their equipment on a regular basis and had their chronic borderline high BP completely controlled. No change in BP values was seen in the last subject, who discontinued N-CPAP after 3 days. A second protocol investigated seven normotensive subjects drawn from the initial subject pool. Continuous radial artery BP recording was performed during nocturnal sleep with simultaneous polygraphic recording of sleep/wake variables and respiration. BP changes were studied during periods of increased respiratory efforts and at the time of alpha EEG arousals. Increases in systolic and diastolic BP were noted during the breaths with the greatest inspiratory efforts without significant hypoxemia. A further increase in BP was noted in association with arousals. Three of these subjects also underwent echocardiography during sleep, which demonstrated a leftward shift of the interventricular septum with pulsus paradoxus in association with peak end-inspiratory esophageal pressure more negative than -35 cm H2O. Our study indicates that, in the absence of classic apneas, hypopneas, and repetitive significant drops in oxygen saturation (below 90%), repetitive increases in BP can occur as a result of increased airway resistance during sleep. It also shows that, in some patients with both UARS and borderline high BP, high BP can be controlled with treatment of UARS. We conclude that abnormal upper airway resistance during sleep, often associated with snoring, can play a role in the development of hypertension.

Adult↗

Transesophageal echocardiography in the intensive care unit: impact on diagnosis and decision-making.

Transesophageal echocardiography (TEE) is widely used in the management of patients in intensive care units. The present study assesses the specific value of this technique in various categories of these patients. We reviewed 113 studies performed in 100 such patients for: suspected aortic dissection (25), suspected endocarditis (33), source of emboli assessment (19), hemodynamic instability (15), and miscellaneous (21). TEE provided diagnostic information in all patients with aortic dissection, in 53% of the cases with hemodynamic instability, in 50% of the cases with septic states with high likelihood of endocarditis, and in 29% of the cases where the question was the source of emboli. When the clinical probability for endocarditis was low, all transesophageal echocardiograms performed in septic patients were negative. The information provided by TEE was considered crucial in one-third of the positive cases; in about one-half of these special cases, the results were instrumental for further surgical management. There were no significant side effects related to the procedure. TEE is easily performed in the intensive care unit setting and yields useful information in almost half of the cases. Special benefit is expected in suspected aortic disease, hemodynamic instability, suspected endocarditis, and embolic events. The overall yield as screening procedure in febrile patients is low.

Adult↗

Filling patterns in left ventricular hypertrophy: a combined acoustic quantification and Doppler study.

OBJECTIVES: The purpose of this study was to evaluate the potential of acoustic quantification compared with Doppler echocardiography for assessment of left ventricular diastolic dysfunction. BACKGROUND: Diastolic dysfunction usually accompanies left ventricular hypertrophy. Although Doppler echocardiography is widely used, it has known limitations in the diagnosis of diastolic abnormalities. The ventricular area-change waveform obtained with acoustic quantification technology may provide an alternative to assess diastolic dysfunction. METHODS: Potential acoustic quantification variables (peak rate of area change and mean slope of area change rate during rapid filling, amount of relative area change during rapid filling and atrial contraction) were obtained and compared with widely used Doppler indexes of ventricular filling (isovolumetric relaxation time, pressure half-time, peak early diastolic velocity/peak late diastolic velocity ratio, rapid filling, atrial contribution to filling) in 16 healthy volunteers and 30 patients with left ventricular hypertrophy. RESULTS: Criteria for abnormal relaxation were present in 68% of patients by acoustic quantification and in 64% of patients by Doppler echocardiography. However, abnormal relaxation was identified in 80% of patients by one or both methods. Acoustic quantification indicated abnormal relaxation in the presence of completely normalized Doppler patterns and in patients with mitral regurgitation or abnormal rhythm with unreliable Doppler patterns. CONCLUSIONS: Acoustic quantification potentially presents a new way to assess diastolic dysfunction. This technique may be regarded as complementary to Doppler echocardiography. The combined use of the methods may improve the diagnosis of left ventricular relaxation abnormalities.

Acoustics↗

On-line estimation of cardiac output with a new automated border detection system using transesophageal echocardiography: a preliminary comparison with thermodilution.

Continuous estimation of cardiac output would be extremely useful for hemodynamic monitoring of patients in the operating room and intensive care settings. A recently developed echocardiographic imaging system provides real-time automated border detection (ABD) with the ability to measure cyclic changes in cavity area, and thus calculate changes in intracavitary volumes. Eight patients undergoing cardiac surgery were studied with intraoperative transesophageal (TEE), and cardiac outputs obtained with this new imaging system were compared with thermodilution (TD). Triplicate measurements were obtained simultaneously at five intraoperative times, three before and two after cardiopulmonary bypass. The 91 of 120 measurements with adequate TEE and TD data were analyzed. The average difference between the two techniques (bias) was -0.2 +/- 1.3 L/min. The limits of agreement (bias +/- 2 SD) were -2.8 L/min to 2.4 L/min. The average of the absolute value of the difference between measurements made with the two techniques was 0.9 +/- 0.8 L/min. Linear regression yielded the equation: ABD = 0.64TD + 1.57 L/min (r = 0.71). The average difference between the two techniques (bias) for detecting changes in cardiac output between sequential intraoperative times was 0.1 +/- 1.1 L/min. With further development, this new method shows promise for measurement of cardiac output in selected patient care settings.

Adult↗

Abnormal postoperative interventricular motion: new intraoperative transesophageal echocardiographic evidence supports a novel hypothesis.

Abnormal interventricular septal motion is a frequent finding after cardiac surgery. However, the time course and underlying mechanisms are not well understood. Nineteen patients, mean age 54 years (range 20 to 82 years), were studied with intraoperative transesophageal echocardiography at five specific times: with the chest closed (baseline), with the chest open and the pericardium closed, with both chest and pericardium open, after cardiopulmonary bypass with the chest open, and after cardiopulmonary bypass with the chest closed. In each patient interventricular septal motion was recorded from the transgastric view; tricuspid annular motion and Doppler color flow mapping of tricuspid regurgitation were obtained from the four-chamber view. All the echocardiographic data were stored on videotape and were later viewed in random sequence by one investigator who was aware of the baseline stage but was blinded to the other stages. All patients had normal septal motion before cardiopulmonary bypass. After cardiopulmonary bypass, with the chest still open, 5 of 17 patients (29%) with adequate recordings had abnormal septal motion while 13 of 17 patients (76%) with adequate recordings had abnormal tricuspid annular motion. After chest closure, only three patients (14%) had normal septal motion and one patient (6%) had normal tricuspid annular motion. Significant tricuspid regurgitation was an infrequent finding in all cases. It is concluded that abnormal interventricular septal motion occurs after cardiopulmonary bypass and is related to abnormal tricuspid annular motion. We hypothesize that suboptimal right ventricular myocardial preservation impairs the motion pattern of the right ventricle, including the tricuspid annulus.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Obstructed breathing in children during sleep monitored by echocardiography.

Six 3 to 14-year-old boys with snoring and obstructive sleep apnea syndrome were monitored polygraphically during sleep with and without nasal continuous positive airway pressure with simultaneous recording of esophageal pressure (Pes) and M-mode and two-dimensional echocardiograms. Continuous non-invasive blood pressure monitoring was performed in two older children. Three of the six children demonstrated a diastolic leftward shift of the interventricular septum related to the negativity of Pes. Progressively more negative Pes correlated significantly with an increase in right ventricular internal end-diastolic dimension and a decrease in left ventricular internal end-diastolic dimension, with at times left ventricular "collapse". One of the subjects with blood pressure monitoring demonstrated pulsus paradoxus with leftward shift of the interventricular septum. Nasal continuous positive airway pressure normalized all changes. Pulsus paradoxus and leftward shift of the interventricular septum are related to the mechanical changes associated with heavy snoring during sleep, regardless of the amount of oxygen desaturation.

Adolescent↗

Comparison of acoustic quantification and Doppler echocardiography in assessment of left ventricular diastolic variables.

OBJECTIVE: To assess the haemodynamic correlations of the waveforms of left ventricular area change obtained by automated boundary detection with newly developed acoustic quantification technology. DESIGN: The timing of events in the cardiac cycle was identified on the wave-form automated boundary detection and was correlated with the corresponding timing derived from pulsed wave Doppler flow velocity traces of the mitral valve and left ventricular outflow tract. The amounts of area change during the rapid filling phase and during atrial contraction were correlated with the time-velocity integrals of early and late diastolic ventricular filling obtained from Doppler tracings of the mitral inflow. SETTING: A university medical school echocardiography laboratory. SUBJECTS: 16 healthy volunteers and 19 patients referred for echocardiographic studies. RESULTS: A significant correlation was found between the methods for measurement of the time from the R wave to mitral valve opening (r = 0.72, p < 0.01), isovolumic relaxation time (r = 0.62, p < 0.01), and ejection time (r = 0.54, p < 0.01). The change of total area that occurred during rapid filling and atrial filling phases measured from the acoustic waveform correlated with the time-velocity integrals of the early and late diastolic mitral valve inflow velocity derived from Doppler echocardiography (r = 0.60 and r = 0.80, respectively). CONCLUSION: The waveform of left ventricular area obtained by the automated boundary detection technique identifies the phases of the cardiac cycle and correlates with Doppler values of left ventricular diastolic function. Therefore, this new method of automated boundary detection has potential uses in the assessment of left ventricular diastolic function.

Acoustics↗

Segmental wall motion abnormalities in patients undergoing total hip replacement: correlations with intraoperative events.

We examined the effect of methylmethacrylate cement on venous embolization and cardiac function in 20 patients having total hip arthroplasty under general anesthesia. Segmental wall motion abnormalities and intracardiac targets (presumably emboli) were investigated by making videotaped recordings of the transgastric short axis and longitudinal 4-chamber views of the heart with transesophageal echocardiography at different points during surgery. The incidence of segmental wall motion abnormalities was the most frequent during insertion of cemented femoral prostheses (8 of 14 patients had wall motion abnormalities). This was significantly different from baseline measurements taken at the beginning of surgery (P < 0.05). In addition, there were also significantly more segmental wall motion abnormalities in patients having a cemented femoral component compared to those having an uncemented femoral prosthesis (P < 0.05). The incidence of wall motion abnormalities during acetabular and femoral reaming and during wound closure was not significantly different from baseline. Intracardiac targets (emboli) were seen in all 20 patients during surgery. The largest number of emboli occurred during reaming of the femur and during insertion of the femoral prosthesis. Significantly more emboli were seen with cemented components (P < 0.02). Most emboli were small (< 2 mm) and appeared similar to the microbubbles produced by agitating saline with a small amount of air. Six patients also had larger (> 5 mm) emboli that appeared to be solid material. One patent foramen ovale was detected (5% incidence). There were no adverse cardiac or neurologic events, and heart rate and arterial blood pressure remained within normal limits throughout surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Systemic venous flow during cardiac surgery examined by intraoperative transesophageal echocardiography.

Patterns of systemic venous return change after cardiac surgery. However, the exact timing and underlying mechanisms are not well understood. To analyze these changes transesophageal echocardiography was used to evaluate 21 patients (mean age 56 +/- 17 years) during cardiac surgery. Eleven patients underwent coronary bypass grafting, 2 had ablation of accessory bundles, 4 had mitral and 4 had aortic valve replacements. All were in sinus rhythm and were undergoing their first cardiac operation. Hepatic and pulmonary venous flow, tricuspid annular motion, and signs of tricuspid regurgitation were recorded sequentially 5 times: (A) with chest closed, (B) with chest open and pericardium closed, (C) with both chest and pericardium open, (D) after cardiopulmonary bypass with chest open, and (E) after cardiopulmonary bypass with chest closed. The hepatic venous Doppler flow velocity integrals (cm) changed, from stage A to stage E: systolic flow decreased from 5.9 +/- 5.2 to 2.2 +/- 1.4 (p less than 0.01); diastolic flow increased from 3.1 +/- 1.5 to 4.8 +/- 3.3 (p less than 0.001); and systolic to diastolic ratio decreased from 2.0 +/- 1.2 to 0.7 +/- 0.6 (p less than 0.001). Reversed flow at the end of ventricular systole was present in 9 patients (43%) at stage A and in all patients at stage E. Decreased tricuspid annular motion was noted in all but 1 patient after cardiopulmonary bypass. No patient presented significant tricuspid regurgitation at any stage. In conclusion, the significant change in the pattern of systemic venous return after open heart surgery is not due to opening of the chest wall or parietal pericardium, or to tricuspid regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗