PubMed Health⌕ Search

Biomedical subjects

I Schnittger

Publications and source records attributed to I Schnittger.

At least 55 records · Page 3Linked to original sources

Ultrasonic tissue characterization: detection of acute myocardial ischemia in dogs.

Ultrasonic tissue characterization is a new area of investigation in the field of cardiac ultrasound. The amplitude and frequency of the ultrasound signal are normally altered as the signal penetrates through tissue. It is assumed that the amplitude distribution and frequency shift of diseased or edematous tissue are different than those of normal tissue. A statistical approach to the analysis of the unprocessed radiofrequency signal in the amplitude domain was used to study the effect of acute myocardial ischemia on the parameter mean amplitude/standard deviation of the amplitude (MSR). Ten dogs were anesthetized and underwent left lateral thoracotomy. Baseline mean MSR from the interventricular septum was 1.99 +/- 0.05, but increased by 30 min after coronary artery occlusion and started to plateau at 1 hr (mean 2.24 +/- 0.06). Reproducibility in noninfarcted myocardium (left ventricular inferoposterior wall) was good, with a mean MSR of 2.00 +/- 0.05 at baseline and 1.98 +/- 0.04 3 to 4 hr later. There was no difference in mean MSR when data were obtained through chest wall and when they were obtained directly from the surface of the heart. We conclude that statistical analysis in the amplitude domain of the unprocessed radiofrequency signal can detect acute myocardial ischemia within 30 min after coronary artery occlusion, provides reproducible measurements, and is unaffected by chest wall filtering.

Animals↗

Computerized quantitative analysis of left ventricular wall motion by two-dimensional echocardiography.

Quantitative detection of left ventricular segmental wall motion abnormalities by any modality depends on the reference system used because of the dynamic geometry of contraction and cardiac motion within the thorax. To assess the feasibility and accuracy of quantitative analysis of left ventricular wall motion by two-dimensional echocardiography, we studied 61 subjects with the use of 44 different reference methods in each of three echocardiographic views: the parasternal short-axis view at the levels of the mitral valve and of the papillary muscles and an apical four-chamber view. The three major groups of reference systems used were those with a fixed external reference, a floating reference correcting for translation, and systems correcting for both translation and rotation. In the first part of this study the end-diastolic and end-systolic outlines of 20 normal subjects were stored in a computer and composite data of these 20 subjects were plotted to obtain a 95% confidence interval for measured normal fractional change for each reference method. In the second part of the project an additional prospective group of 10 normal subjects and a group of 31 "abnormal" patients had their left ventricular wall motion analyzed by similar methods and the results were compared with all the confidence intervals. One reference method was selected for each two-dimensional echocardiographic view based on the highest sensitivity and specificity found by statistical analysis; a floating-reference system including translation was found to be optimal for the apical four-chamber and parasternal short-axis views at the level of the mitral valve and a fixed external reference system was optimal for the short-axis view at the papillary level. The percent fractional shortening of radial dimensions (radial methods) and the percent fractional change in area measurements (area methods) during the cardiac cycle were also calculated at 5, 10, 20, 30 and 45 degree intervals around the outline perimeter for each subject according to each of the 44 different methods. Area methods yielded the same specificity and sensitivity as radial dimension analysis methods at 5 to 45 degree intervals. Ten normal subjects underwent repeat echocardiography within 2 days of their first study to examine day-to-day variation. Average change in mean contraction from day to day was 7% to 9% for radial methods and 9% to 13% for area methods. In conclusion, we present a computerized system for unbiased selection of optimal methods of analysis of left ventricular wall motion by two-dimensional echocardiography.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

An improved stochastic approach to rf amplitude analysis in ultrasonic cardiac tissue characterization.

We carried out a series of studies to improve the reproducibility of methods for ultrasonic myocardial tissue characterization using a stochastic approach to amplitude analysis of radiofrequency signals previously reported from our laboratory. Analysis of transducer scanner characteristics, data acquisition and processing, and data display from studies in tissue phantoms permit us to define some features of a parameter for expression of tissue character. The ratio of mean to standard deviation of the amplitude histogram from our system is explored as now implemented in our laboratory for reproducible measurements. The theoretical basis for understanding the utility of this method in defining tissue architecture and pathologic conditions requires further work.

Animals↗

Rapid, semiautomated technique for estimating left ventricular volume.

A new system for rapidly quantitating left ventricular volume using two-dimensional echocardiography is tested. This system relies on a microprocessor built into a sector scanner that immediately calculates the length, area, and volume of the chamber being imaged using the mathematical model of an ellipsoid of revolution. The calculations are made after the observer superimposes a smooth calibrated ellipse outline on the endocardium imaged with the sector scanner. We report our experience with this system in 50 patients with a variety of cardiac disorders and compare the left ventricular volumes measured with those obtained using cineangiography, M-mode, and more detailed light pen tracing techniques. Correlations between volumes measured with the elliptical calipers and angiography were good (r = 0.820, SEE +/- 38.8 ml) (n = 100), but not as good as that between light pen tracing of the echo images and angiography (r = 0.847, SEE +/- 27.8 ml) (n = 22). M-mode correlated less well with angiography (r = 0.789; SEE +/- 42.1 ml) (n = 90). We conclude that the calibrated ellipse system is rapid and simple to use, while its accuracy matches previous studies using two-dimensional echocardiography to quantitate left ventricular volume.

Cardiovascular Diseases↗

Standardized intracardiac measurements of two-dimensional echocardiography.

Thirty-five healthy adults were studied by two-dimensional echocardiography to attempt to standardize a simple method for measurement of intracardiac dimensions. Both ventricles and the atria and aorta were measured in five different views: parasternal long-axis, parasternal short-axis at the level of the aortic valve, the chordae tendineae and the papillary muscles and an apical four chamber view. The minor axis of each chamber was measured in all five views; the major axis in the apical four chamber view also was measured. All measurements are presented as a range of values (mean and 2 standard deviations about the mean); the mean value is given as well as the absolute range of values measured. Normalization according to body surface area is also presented. Data from these multiple views allow assessment of asymmetry of cardiac chambers in normal subjects. The mean minor axis dimension at end-diastole of the right ventricle in the parasternal long-axis view (1.9 to 3.8 cm) was 13.6% smaller than in the four chamber view (2.2 to 4.4 cm), whereas the minor axis dimension of the left ventricle in the parasternal long-axis view (3.5 to 6.0 cm) was only 1.1% larger than in the four chamber view (3.3 to 6.0 cm). Therefore, the right ventricular minor axis dimensions are not interchangeable. Reproducibility in 10 subjects for all dimensions showed a maximal variability of 4.8%. These values permit a standardized and expeditious method for measuring intracardiac dimensions by two-dimensional echocardiography.

Adolescent↗

Reproducibility of left ventricular volumes by two-dimensional echocardiography.

Reproducibility may be as important as absolute accuracy in assessing the utility of an echocardiographic method of left ventricular volume estimation for epidemiologic or physiologic studies. The magnitude of differences between measurements in the same subjects from day to day must be defined before any quantitative technique can be used reliably to document "real" changes in heart volume over time. Two-dimensional echocardiograms were performed serveral days apart in 30 subjects, including 20 normal subjects and 10 patients with stable coronary heart disease. Analyses of light-pen tracings provided measurements of end-diastolic volume, endsystolic volume and derived ejection fraction on both days, and differences in individual subjects between days were quantitated. Beat to beat, interobserver and intraobserver variability also were assessed. Although group values changed little from day to day, individual volume changes were substantial in some cases. Confidence limits for individual measurements were derived from analyses of intrasubject variability and were as follows: end-diastolic volume +/- 15%, end-systolic volume +/- 25%, ejection fraction +/- 10%. Confidence limits in a larger group of subjects were narrower; in a group of 30 subjects, changes of greater than 2% in end-diastolic volume, 5% in end-systolic volume and 2% in ejection fraction most likely represent real change. Intraobserver variability was minimal, but interobserver and beat to beat variability were of sufficient magnitude to suggest that serial measurements on a given subject be made ideally by a single person and that several cycles be averaged for a given measurement.

Adult↗

Time dependency of ventricular fibrillation thresholds determined using trains of stimuli.

When determining ventricular fibrillation threshold (VFT), considerable time elapses from beginning a VFT measurement until the actual occurrence of ventricular fibrillaion (VF). We have defined this elapsed time as the "time to VF" and examined the effect of varying time to VF on the measured value of VFT. We induced VF in anesthetized dogs with a 100-Hz train of 16 4-ms stimuli applied to the right ventricular epicardium. The time to VF was varied by changing either the increment of fibrillation current increase (0.5, 1.0, or 2.0 mA) from one train to the next and/or the number of atrial paced beats between trains (6-192 beats). For 0.5-mA current increments, as time to VF increased from 66 to 454 s, VFT fell progressively from 15.3 +/- 4.8 to 6.7 +/- 1.1 mA. When time to VF exceeded 454 s, VFT increased again. Current increments of 1.0 and 2.0 mA had a similar time dependency of VFT. For any time to VF the VFT was lower when small current increments (i.e., more trains) were used to induce VF. Pretreatment with reserpine in six dogs abolished the time dependency. We conclude that time elapsed from the beginning of a VFT determination until VF actually occurs and the total number of trains used are important determinants of the VFT, probably because of local catecholamine release by the stimuli.

Animals↗

Echocardiography: pericardial thickening and constrictive pericarditis.

A total of 167 patients with pericardial thickening noted on M node echocardiography were studied retrospectively. After the echocardiogram, 72 patients underwent cardiac surgery, cardiac catheterization or autopsy for various heart diseases; 96 patients had none of these procedures. In 49 patients the pericardium was directly visualized at surgery or autopsy; 76 percent of these had pericardial thickening or adhesions. In another 8 percent, pericardial adhesions were absent, but no comment had been made about the appearance of the pericardium itself. In the remaining 16 percent, no comment had been made about the pericardium or percardial space. Cardiac catheterization in 64 patients revealed 24 with hemodynamic findings of constrictive pericarditis or effusive constrictive disease. Seven echocardiographic patterns consistent with pericardial adhesions or pericardial thickening are described and related when possible to the subsequent findings at heart surgery or autopsy. The clinical diagnoses of 167 patients with pericardial thickening are presented. The hemodynamic diagnosis of constrictive pericardial disease was associated with the echocardiographic finding of pericardial thickening, but there were no consistent echocardiographic patterns of pericardial thickening diagnostic of constriction. However, certain other echocardiographic abnormalities of left ventricular posterior wall motion and interventricular septal motion and a high E-Fo slope were suggestive of constriction.

Echocardiography↗

Biplane transesophageal echocardiography in the diagnosis of patent foramen ovale.

Patent foramen ovale is associated with unexplained systemic embolic events or persistent hypoxemia. The diagnosis of a patient foramen ovale is based on the existence of an interatrial right-to-left shunt. Biplane transesophageal echocardiography with its increased ability to provide accurate anatomic detail may allow the visualization of the actual opening of the patent foramen ovale. In 19 patients with transesophageal positive contrast studies, we assessed the value of the vertical versus the horizontal plane in the diagnosis of a patent foramen ovale. The patent foramen ovale opening could be seen and sized in the vertical plane in 10 studies (53%). In none of these 10 cases was the opening seen also in the horizontal plane. We conclude that in a significant number of cases, biplane transesophageal echocardiography adds morphological detail to the diagnosis of patent foramen ovale. The ability to size the actual opening may have therapeutic implications.

Contrast Media↗

Flow velocity acceleration in the left ventricle: a useful Doppler echocardiographic sign of hemodynamically significant mitral regurgitation.

Doppler echocardiography is a sensitive method to detect mitral regurgitation in patients with both native and prosthetic valves. However, estimates of the amount of mitral regurgitation remain semiquantitative, and even severe mitral regurgitation may be underestimated in the presence of markedly eccentric regurgitant jets or acoustic shadowing of the left atrium by mitral or aortic prostheses. This report describes the Doppler findings in 10 patients with severe native valve mitral regurgitation (angiographic grade III or IV) and in 15 patients with severe bioprosthetic mitral regurgitation that required valve replacement. An increase in peak mitral flow velocity above normal values was seen in eight of 10 patients with severe native valve mitral regurgitation (greater than or equal to 130 cm per second) and 11 of 15 patients with severe prosthetic valve mitral regurgitation (greater than or equal to 210 cm per second). One of 10 patients with a native valve and four of 15 patients with a bioprosthetic valve appeared to have only a localized left atrial systolic flow disturbance, incorrectly suggesting that the mitral regurgitation was mild. However, in all patients with severe mitral regurgitation, a low velocity (less than 100 cm per second) flow signal could be recorded in the left ventricle that was directed toward the mitral valve in systole. This flow signal showed a gradual increase in velocity as the sample volume was moved toward the mitral valve, with an abrupt further increase on entry into the left atrium. This signal was continuous with antegrade mitral flow and had the same orientation as mitral regurgitation recorded by continuous wave technique from the apex. A similar flow signal was not recorded in the left ventricle of any individual in a control group of 30 patients who had no mitral regurgitation or who had angiographic grade I or II mitral regurgitation. These findings suggest that acceleration of left ventricle flow toward the mitral valve in systole is only recorded when there is hemodynamically significant mitral regurgitation that is approximately equal to angiographic grade III or IV. Recognition of this Doppler finding may help in the estimation of mitral regurgitation severity, especially in difficult diagnostic situations.

Aged↗

Transesophageal echo-Doppler echocardiographic assessment of pulmonary venous flow patterns.

UNLABELLED: Fifty-eight of 61 consecutive patients undergoing transesophageal echo-Doppler echocardiography provided excellent signals to permit assessment of pulmonary venous blood low patterns. Normal antegrade pulmonary venous flow during ventricular systole was biphasic and was characterized by a short, low velocity (28 +/- 17 cm/sec), early systolic jet (P1), and longer, higher velocity (41 +/- 23 cm/sec), late systolic jet (P2). Antegrade pulmonary venous flow during ventricular diastole (P3) was of moderate velocity (34 +/- 17 cm/sec) and was monophasic; during atrial contraction there was transient, low velocity (-17 +/- 11 cm/sec) and reversal of flow (P4). The early systolic antegrade venous flow (P1) was absent or reversed in rhythm disorders, which interrupted normal synchronized atrioventricular activation. These rhythm disorders also were associated with diminished peak flow velocities during late systole (P2). Abnormalities in systolic left ventricular function and mitral regurgitation also had this effect. Diastolic flow velocities (P3) remained constant, except in patients with mitral regurgitation. In these patients diastolic peak flows were significantly increased above normal. In cases of atrial fibrillation or ventricular pacing the late diastolic reversal of flow resulting from atrial contraction (P4) was absent. CONCLUSIONS: Transesophageal echo-Doppler echocardiography gives high quality signals of pulmonary venous inflow to help assess function of the left ventricle and left atrium. Multiple factors affect the patterns. This study suggests caution in the interpretation of abnormal patterns, particularly of reduced systolic pulmonary vein flow in the presence of left ventricular dysfunction, atrial fibrillation, ventricular pacing, and mitral regurgitation.

Adult↗

Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms.

We have presented recommendations for the optimum acquisition of quantitative two-dimensional data in the current echocardiographic environment. It is likely that advances in imaging may enhance or supplement these approaches. For example, three-dimensional reconstruction methods may greatly augment the accuracy of volume determination if they become more efficient. The development of three-dimensional methods will depend in turn on vastly improved transthoracic resolution similar to that now obtainable by transesophageal echocardiography. Better resolution will also make the use of more direct methods of measuring myocardial mass practical. For example, if the epicardium were well resolved in the long-axis apical views, the myocardial shell volume could be measured directly by the biplane method of discs rather than extrapolating myocardial thickness from a single short-axis view. At present, it is our opinion that current technology justifies the clinical use of the quantitative two-dimensional methods described in this article. When technically feasible, and if resources permit, we recommend the routine reporting of left ventricular ejection fraction, diastolic volume, mass, and wall motion score.

Algorithms↗

Assessment of left ventricular wall motion abnormalities with the use of color kinesis: a valuable visual and training aid.

Accurate interpretation of left ventricular segmental wall motion by echocardiography is an important yet difficult skill to learn. Color-coded left ventricular wall motion (color kinesis) is a tool that potentially could aid in the interpretation and provide semiquantification. We studied the usefulness of color kinesis in 42 patients with a history of congestive cardiomyopathy who underwent two-dimensional echocardiograms and a color kinesis study. The expert's reading of the two-dimensional wall motion served as a reference for comparison of color kinesis studies interpreted by the expert and a cardiovascular trainee. Correlation between two-dimensional echocardiography and the expert's and trainee's color coded wall motion scores were r = 0.83 and r = 0.67, respectively. Reproducibility between reviewers and between operators was also assessed. Interobserver variability for color-coded wall motion showed a correlation of r = 0.78. Correlation between operators was also good; r = 0.84. Color kinesis is reliable and appears promising as an adjunct in the assessment of wall motion abnormalities by echocardiography. It is both a valuable visual aid, as well as a training aid for the cardiovascular trainee.

Adult↗