PubMed Health⌕ Search

Biomedical subjects

I Stockley

Publications and source records attributed to I Stockley.

At least 19 recordsLinked to original sources

Clinical and radiological outcome of total hip replacement five years after pamidronate therapy. A trial extension.

Bisphosphonates reduce peri-prosthetic bone loss in the short term after total hip replacement but the mid- and longer term effects are not known. The aims of this randomised trial were to examine the effect of a single dose of 90 mg of pamidronate on the clinical and radiological outcome and peri-prosthetic bone mineral density in 50 patients (56 hips) over a five-year period, following total hip replacement. At five years, 37 patients (42 hips) returned for assessment. The Harris hip scores were similar in the pamidronate and placebo groups throughout the study. Also at five years, four patients, two from each group had osteolytic lesions on plain radiography. These were located around the acetabular component in three patients and in the femoral calcar in one. The femoral and acetabular peri-prosthetic bone mineral density in the pamidronate group and the control group was similar at five years. Pamidronate given as a single post-operative dose does not appear to influence the clinical outcome or prevent the development of osteolytic lesions at five years after total hip replacement.

Absorptiometry, Photon↗

Bone remodelling around a cemented polyethylene cup. A longitudinal densitometry study.

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery. The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years. Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.

Absorptiometry, Photon↗

Is there a role for extended antibiotic therapy in a two-stage revision of the infected knee arthroplasty?

All major studies have incorporated the use of prolonged courses of parenteral or oral antibiotic therapy in the management of two-stage revision of an infected total knee arthroplasty. We present a series of 59 consecutive patients, all with microbiologically-proven deep infection of a total knee arthroplasty, in whom a prolonged course of antibiotic therapy was not routinely used. The mean follow-up was 56.4 months (24 to 114). Of the 38 patients who underwent a staged exchange, infection was successfully eradicated in 34 (89%) but recurrent or persistent infection was present in four (11%). Our rate of cure for infection is similar to that reported elsewhere. We conclude that a prolonged course of antibiotic therapy seems not to alter the incidence of recurrent or persistent infection. The costs of the administration of antibiotics are high and such a regime may be unnecessary.

Adult↗

Irradiated allograft bone for acetabular revision surgery. Results at a mean of five years.

We report the results of the revision of 123 acetabular components for aseptic loosening treated by impaction bone grafting using frozen, morsellised, irradiated femoral heads and cemented sockets. This is the first large series using this technique to be reported. A survivorship of 88% with revision as the end-point after a mean of five years is comparable with that of other series.

Adult↗

The use of structural proximal femoral allografts in complex revision hip arthroplasty.

Between April 1992 and November 1998 we used 34 massive proximal femoral allografts for femoral reconstruction at revision hip arthroplasty. Seven patients have died and two have been lost to follow-up. There were thus 25 grafts in 24 patients for review. The mean follow-up was 53 months (16 to 101). By the time of the review two patients had undergone a further revision for failure of the allograft. Another had required secondary plating and grafting at the graft-host junction for symptomatic nonunion. One had recurrence of deep sepsis and was being managed conservatively. Trochanteric union was considered to have occurred radiologically in 16 of the 25 grafts and union at the host-graft junction in 20. Resorption of the allograft was significant in only two hips. We recommend this technique in cases in which femoral bone loss has been catastrophic.

Adult↗

Allograft bone in two-stage revision of the hip for infection. Is it safe?

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft. Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock.

Adult↗

Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty.

We assessed the precision of the EBRA-Digital software (EBRA, University of Innsbruck, Innsbruck, Austria) for measuring implant migration after total hip arthroplasty. Study subjects (n = 29) underwent consecutive, standardized, plain radiographic examinations of the hip on the same day after repositioning. The resulting radiograph pairs were digitized and analyzed using EBRA. The precision (95% confidence interval) of the method for measuring migration and wear was <+/-0.9 mm for both implant components. The 95% confidence intervals for measurement of cup inclination and anteversion and femoral stem/shaft angle were <+/-1.7 degrees. Measurement precision was not strongly related to patient gender, digitization method, or observer. The EBRA-Digital method has sufficient precision to detect clinically relevant migration to allow individual patient monitoring after total hip arthroplasty. The method requires careful patient positioning and radiographic technique to produce consistently images suitable for analysis.

Arthroplasty, Replacement, Hip↗

The use of vancomycin-impregnated cement beads in the management of infection of prosthetic joints.

Although the incidence of infection associated with hip and knee prostheses is low, with the increasing number of arthroplasties being carried out, the total number of such cases is increasing. The pattern of infecting organisms after total joint arthroplasty has changed and gentamicin-resistant organisms are becoming increasingly common. In conjunction with surgical debridement, vancomycin added to a bone-cement carrier can be very effective in the treatment of infection caused by such organisms. We report the results of its use in proven deep infection in 26 hip and seven knee arthroplasties. After a mean follow-up of 67 months, 32 patients remained clinically and radiologically free from infection. There was one recurrence and positive second-stage cultures of uncertain significance in three other patients. Vancomycin is potentially very useful in the management of deep infection after arthroplasty.

Aged↗

Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty.

We aimed to evaluate the precision and longitudinal sensitivity of measurement of bone mineral density (BMD) in the pelvis and to determine the effect of bone cement on the measurement of BMD in femoral regions of interest (ROI) after total hip arthroplasty (THA). A series of 29 patients had duplicate dual-energy x-ray absorptiometry (DXA) scans of the hip within 13 months of THA. Pelvic analyses using 3- and 4-ROI models gave a coefficient of variation (CV) of 2.5% to 3.6% and of 2.5% to 4.8%, respectively. Repeat scans in 17 subjects one year later showed a significant change in BMD in three regions using the 4-ROI model, compared with change in only one region with the 3-ROI model (p < 0.05). Manual exclusion of cement from femoral ROIs increased the net CV from 1.6% to 3.6% (p = 0.001), and decreased the measured BMD by 20% (t = 12.1, p < 0.001). Studies of two cement phantoms in vitro showed a small downward drift in bone cement BMD giving a measurement error of less than 0.03 g/cm2/year associated with inclusion of cement in femoral ROIs. Changes in pelvic periprosthetic BMD are best detected using a 4-ROI model. Analysis of femoral ROI is more precise without exclusion of cement although an awareness of its effect on the measurement of the BMD is needed.

Adult↗

Effect of pamidronate in preventing local bone loss after total hip arthroplasty: a randomized, double-blind, controlled trial.

Acute periprosthetic bone loss occurs after total hip arthroplasty. Bone loss undermines the support of the implant and may contribute to prosthetic failure. At present, there is no established prophylaxis for this process. We studied the effect of a single-dose infusion of 90 mg of pamidronate on early periprosthetic bone mineral density (BMD), biochemical markers of bone turnover, radiological, and clinical outcome in a 26-week, prospective, randomized, double-blinded study of 47 men and women undergoing total hip arthroplasty. Pamidronate therapy led to a significant reduction in bone loss compared with placebo for both the proximal femur and the pelvis (repeated measures analysis of variance [ANOVA]); p = 0.001 and p = 0.01, respectively). Pamidronate therapy was associated with suppression of all biochemical markers of bone turnover compared with placebo (repeated measures ANOVA; p < 0.05 for all comparisons), with the exception of urinary free deoxypyridinoline. Pamidronate did not interfere with the clinical improvement in symptoms after total hip arthroplasty, or radiological outcome, and was not associated with an increase in adverse events. This study provides clinical data on the efficacy and safety of bisphosphonates for the prevention of bone loss after total hip arthroplasty and supports the establishment of larger-scale clinical trials to determine the long-term clinical efficacy of this intervention using implant failure as the primary endpoint.

Aged↗

Effect of mixing technique on the properties of acrylic bone-cement: a comparison of syringe and bowl mixing systems.

Syringe mixing systems have been introduced, but few data exist regarding the mechanical performance of cement they produce. We compared the properties of polymethyl methacrylate cement produced by these systems with that produced by a multiaxial bowl. Mixtures of cement were prepared using the Optivac, Cemvac, and Summit syringes and the Summit bowl. The mixtures were cured in molds to create casts that were radiographed and analyzed for void content, then cut into strips, weighed, measured, and tested to failure in 4-point bending. Syringe-mixed cement was of greater density, bending modulus, and bending strength than bowl-mixed cement (Mann-Whitney, P < .01) and contained fewer microvoids and macrovoids (Mann-Whitney, P < .01). No significant differences between the syringes were found for these variables (Kruskall-Wallis, P > .05).

Bone Cements↗

Changes in allograft bone irradiated at different temperatures.

Secondary sterilisation of allograft bone by gamma irradiation is common, but the conditions under which it is performed vary between tissue banks. Some do so at room temperature, others while the bone is frozen. Bone is made brittle by irradiation because of the destruction of collagen alpha chains, probably mediated by free radicals generated from water molecules. Freezing reduces the mobility of water molecules and may therefore decrease the production of free radicals. We found that bone irradiated at -78 degrees C was less brittle and had less collagen damage than when irradiated at room temperature. These findings may have implications for bone-banking.

Adult↗

Allograft bone transplantation: a Sheffield experience.

There has been an increase in demand for allograft bone in recent years. This type of bone provides an excellent material to fill in bony defects, but could be associated with an incidence of infection. Any newly established tissue bank has to meet the very stringent criteria to process and store bone and maintain a donor and recipient database to avoid transmission of infection. The Sheffield Tissue Bank has been functioning since 1989 and until 1993 has provided bone allografts to 220 patients; these have been used mainly to reconstruct defects at revision hip and knee arthroplasty and for scoliosis surgery. There have been no cases of disease transmission and the rate of infection has been reduced by strict screening protocols. This paper outlines our experience, problems and success with human bone banking.

Adolescent↗

Surgical management of fractures of the acetabulum: the Sheffield experience 1976-1994.

Of 56 acetabular fractures treated in Sheffield between 1976 and 1994, 43 fractures in 40 patients underwent open reduction and internal fixation. This paper reviews the surgically managed fractures with emphasis on the quality of operative reduction and outcome, in particular the development of degenerative osteoarthritis leading to total hip replacement. A good clinical result following operative management was seen to correlate closely with a near perfect reduction; in contrast, all cases with a poor reduction underwent joint replacement in the follow-up period. The relatively few cases managed at a major referral centre in this series suggest that either the incidence of acetabular fracture is low in the area or that only a proportion of cases are referred from the surrounding district general hospitals.

Acetabulum↗