PubMed Health⌕ Search

Biomedical subjects

I Tort Ausina

Publications and source records attributed to I Tort Ausina.

2 recordsLinked to original sources

Organ doses, detriment and genetic risk from interventional vascular procedures in Málaga (Spain).

Nowadays, the radiological risk from simple X-ray procedures is well known. The purpose of this work has been to estimate the population risk from digital angiographic and interventional procedures and to compare it with the one from simple procedures in the same population. The population risk has been estimated according to the following quantities: genetically significant dose, somatic significant dose, collective effective dose, annual per caput effective dose and detriment. These have been estimated from dose area product and organ dose. Organ dose values were estimated with the Eff-Dose software. A population of 605410 people were included in the study. In 1996, 1312 patients were to digital interventional vascular procedures in Malaga, and 159 of them were selected in this research project to obtain the dose area product and organ dose. The results obtained for the quantities evaluated are: genetically significant dose, 4.1 microGy; somatic significant dose, 0.9 mSv; collective effective dose, 11.65 person-Sv: annual per caput effective dose, 0.02 mSv and detriment, 0.65 radiogenic cancers per year. These procedures supply a high radiation dose, so they should have a greater contribution to population dose and risk than simple examinations. However, our results indicate just the opposite.

Adolescent↗

Patient dose from barium procedures.

The objective of this work was to estimate patient doses (dose-area product, organ dose, effective dose and entrance surface dose) for barium procedures. A total of 175 procedures, in 175 patients, for five different examination categories was analysed. Dose-area product was determined using a transmission ionization chamber. Organ dose and effective dose were assessed using a knowledge of the examination and the software. For all patients, the contribution of fluoroscopy to the total dose was greater than that from radiography. Dose-area product from double contrast barium enema, enteroclysis and intestinal tract procedures was higher than that obtained for the other procedures. The average effective dose was 1.04 mSv and 13.99 mSv for oesophageal tract and enteroclysis examinations, respectively. Entrance surface dose in the oesophageal tract was 16 mGy, 10 times lower than for the other four procedures. Patient dose reduction in barium procedures may be achieved by improved training of resident radiologists, senior radiologists and other specialists in radiation protection.

Adult↗