PubMed Health⌕ Search

Biomedical subjects

I W Levin

Publications and source records attributed to I W Levin.

At least 19 recordsLinked to original sources

Conformational differences in protein disulfide linkages between normal hair and hair from subjects with trichothiodystrophy: a quantitative analysis by Raman microspectroscopy.

Raman spectra of normal hair shafts and hair shafts from patients exhibiting trichothiodystrophy (TTD) were obtained using line focus laser illumination. Because hair from TTD patients has a significant decrease in the content of the sulfur-containing amino acids in comparison to normal hair, the 550-500 cm(-1) disulfide stretching mode region of the Raman spectrum was examined in detail. A quantitative spectral analysis demonstrates significant increases in the two energetically less favored gauche-gauche-trans (g-g-t) and trans-gauche-trans (t-g-t) forms. These observations suggest that the increased amounts of these less stable disulfide conformers are contributing factors to or associated with the hair brittleness observed for this congenital disorder. Structure-spectra correlations for the three dominant disulfide conformers are confirmed by quantum chemical calculations using modern density functional theory (DFT).

Biopolymers↗

Noninvasive determination of spatially resolved and time-resolved tissue perfusion in humans during nitric oxide inhibition and inhalation by use of a visible-reflectance hyperspectral imaging technique.

BACKGROUND: Vascular disease is commonly associated with reduced local synthesis of nitric oxide (NO) and impaired tissue perfusion. We introduce a novel noninvasive, visible-reflectance, hyperspectral imaging technique for quantifying the percentage of hemoglobin existing as oxyhemoglobin (HbO(2)) as an index of skin tissue perfusion. METHODS AND RESULTS: To simulate vascular endothelial dysfunction, N(G)-monomethyl-L-arginine (L-NMMA) was infused into the brachial arteries of 9 healthy subjects for 5 minutes to inhibit forearm NO synthesis, first with the subject breathing room air and subsequently during NO inhalation at 80 ppm for 1 hour. Blood flow was measured by venous occlusion plethysmography, and the percentage of HbO(2) perfusing skin tissue was imaged noninvasively with a visible-reflectance hyperspectral technique. L-NMMA reduced blood flow by 31.7+/-4.9% and percentage of HbO(2) by 6.5+/-0.1 (P=0.002 and P<0.001 versus baseline, respectively). With subjects inhaling NO, blood flow fell during L-NMMA infusion by only 10.9+/-7.3%, and the percentage of HbO(2) decreased by 3.6+/-0.1 (P=0.007 and P<0.001, respectively, versus room air L-NMMA responses). CONCLUSIONS: Visible-reflectance hyperspectral imaging demonstrates (1) a significant decline in the percentage of HbO(2) in skin tissue when blood flow is reduced after inhibition of forearm NO synthesis and (2) restoration of HbO(2) toward basal values with improved blood flow during inhalation of NO. This imaging method may provide an effective approach for time-resolved noninvasive monitoring of skin hemoglobin oxygen saturation and assessment of responses to therapeutic interventions in patients with vascular disease.

Administration, Inhalation↗

Fourier transform infrared imaging: theory and practice.

The signal-to-noise ratio (SNR) of spectral data obtained from a microimaging Fourier transform infrared (FT-IR) spectrometer assembly, employing a step-scan interferometer and focal plane array detector, is analyzed. Based on the methodology of data collection, a theoretical description for the performance characteristics is proposed and quantitative effects of the acquisition parameters on the SNR are explained theoretically and compared to experiment. To obtain the best strategy for achieving either the highest SNR in a given time interval or for attaining a given SNR in the shortest time period, the concept of characteristic plots is introduced. The theoretical analysis is extended to FT-IR microimaging employing continuous scan interferometers in which the advantages of fast image collection are enumerated, while SNR limitations arising from mirror positioning errors are discussed. A step-scan method is suggested for faster data collection in which an optimal detector response and SNR benefits are retained. Theoretically obtained SNRs based upon the expressions proposed in this paper predict experimentally determined values quite well and can be used to obtain an understanding of the required developments for improved performance. Finally, SNRs for both microimaging systems and conventional microspectroscopic instrumentation are compared.

Journal Article↗

Imaging of collagen and proteoglycan in cartilage sections using Fourier transform infrared spectral imaging.

OBJECTIVE: To test the hypothesis that Fourier transform infrared (FTIR) spectral imaging, coupled with multivariate data processing techniques, can image the spatial distribution of matrix constituents in native and engineered cartilage samples. METHODS: Tissue sections from native and trypsin-digested bovine nasal cartilage (BNC) and from engineered cartilage, generated by chick sternal chondrocytes grown in a hollow fiber bioreactor, were placed either on calcium fluoride windows for FTIR analysis or gelatinized microscope slides for histologic analysis. Based on the assumption that cartilage is predominantly chondroitin sulfate (CS) and type II collagen, chemical images were extracted from FTIR spectral imaging data sets using 2 multivariate methods: the Euclidean distance algorithm and a least-squares approach. RESULTS: Least-squares analysis of the FTIR data of native BNC yielded a collagen content of 54 +/- 13% and a CS content of 37 +/- 16% (mean +/- SD). Euclidean distance analysis of measurements made on trypsin-digested BNC demonstrated only trace amounts of CS. For engineered cartilage, the CS content was significantly lower (15 +/- 5%), while the collagen content (73 +/- 6%) was significantly higher than biochemically determined values (CS 34%, collagen 5%, protein 61%). These differences are due to the fact that the dimethylmethylene blue assay overestimated the CS content of the tissue because it is not specific for CS, while the FTIR spectral imaging technique overestimated the collagen content because it lacks specificity for different proteins. CONCLUSION: FTIR spectral imaging combines histology-like spatial localization with the quantitative capability of bulk chemical analysis. For molecules with a unique spectral signature, such as CS, the FTIR technique coupled with multivariate analysis can define a unique spatial distribution. However, for some applications, the lack of specificity of this technique for different types of proteins may be a limitation.

Animals↗

Raman spectroscopic study of polycrystalline mono- and polyunsaturated 1-eicosanoyl-d(39)-2-eicosenoyl-sn-glycero-3-phosphocholines: bilayer lipid clustering and acyl chain order and disorder characteristics.

Polycrystalline lipid samples of a series of mono- and polyunsaturated, double bond positional isomers of 1-eicosanoyl-d(39)-2-eicosenoyl-sn-glycero-3-phosphocholines [C(20-d(39)):C(20:1 Delta(j))PC, with j = 5, 8, 11, or 13; C(20-d(39)):C(20:2 Delta(11,14))PC; and C(20-d(39)):C(20:3 Delta(11, 14,17))PC] were investigated using vibrational Raman spectroscopy to assess the acyl chain packing order-disorder characteristics and putative bilayer cluster formation of the isotopically differentiated acyl chains. Perdeuteration of specifically the saturated sn-1 acyl chains for these bilayer systems enables each chain's intra- and intermolecular conformational and organizational properties to be evaluated separately. Various saturated chain methylene CD(2) and carbon-carbon (C&bond;C) stretching mode peak height intensity ratios and line width parameters for the polycrystalline samples demonstrate a high degree of sn-1 chain order that is unaffected by either the double bond placement or number of unsaturated bonds within the sn-2 chain. In contrast, the unsaturated sn-2 chain spectral signatures reflect increasing acyl chain conformational disorder as either the cis double bond is generally repositioned toward the chain terminus or the number of double bonds increases from one to three. The lipid bilayer chain packing differences observed between the sn-1 and sn-2 chains of this series of monounsaturated and polyunsaturated 20 carbon chain lipids suggest the existence of laterally distributed microdomains predicated on the formation of highly ordered, saturated sn-1 chain clusters.

Eicosanoic Acids↗

Infrared microspectroscopic imaging of the cerebellum of normal and cytarabine treated rats.

Conventionally, the diagnosis of neuropathology in a subject requires the identification of a behavioral modification, which provides direction for appropriate histological analyses. However, since the ultimate diagnosis of the pathology largely depends on the initial choice of histological tests, the opportunity exists for inaccurate or insensitive results. An innovative approach using Fourier transform infrared (FT-IR) spectroscopic imaging to diagnose neuropathology should prove useful. This novel method monitors and visualizes the underlying chemistry of the tissue, based on hundreds of vibrational absorption bands that are intrinsic to the sample. As such, it makes no prior assumptions as to the type or degree of pathology. Using this technique, we have spectroscopically imaged cerebellar tissue slices from rats [control subjects and subjects treated with the antineoplastic drug, cytarabine (Ara-C)], and have been able to correlate lipid and protein distributions within distinct cell types in the cerebellum. A further benefit of the technique is that it simultaneously records tens of thousands of independent spectra from different spatial locations within the sample. Thus, a variety of statistical and multivariate techniques can be exploited to characterize large sample areas and to provide robust classification of individual spectral signatures. In comparison to standard histological protocols, FT-IR spectroscopic imaging simultaneously analyzes cell layers and identifies subtle structural and biochemical changes within the sample. We suggest that FT-IR spectroscopic imaging should provide a highly reliable, complementary tool for standard histological tier testing.

Animals↗

Packing characteristics of two-component bilayers composed of ester- and ether-linked phospholipids.

The miscibility properties of ether- and ester-linked phospholipids in two-component, fully hydrated bilayers have been studied by differential scanning calorimetry (DSC) and Raman spectroscopy. Mixtures of 1,2-di-O-hexadecyl-rac-glycero-3-phosphocholine (DHPC) with 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine (DHPE) and of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) with 1,2-di-O-hexadecyl-sn-glycero-3-phosphoethanolamine (DHPE) have been investigated. The phase diagram for the DPPC/DHPE mixtures indicates that these two phospholipids are miscible in all proportions in the nonrippled bilayer gel phase. In contrast, the DHPC/DPPE mixtures display two regions of gel phase immiscibility between 10 and 30 mol% DPPE. Raman spectroscopic measurements of DHPC/DPPE mixtures in the C-H stretching mode region suggest that this immiscibility arises from the formation of DHPC-rich interdigitated gel phase domains with strong lateral chain packing interactions at temperatures below 27 degrees C. However, in the absence of interdigitation, our findings, and those of others, lead to the conclusion that the miscibility properties of mixtures of ether- and ester-linked phospholipids are determined by the nature of the phospholipid headgroups and are independent of the character of the hydrocarbon chain linkages. Thus it seems unlikely that the ether linkage has any significant effect on the miscibility properties of phospholipids in biological membranes.

1,2-Dipalmitoylphosphatidylcholine↗

Visualization of silicone gel in human breast tissue using new infrared imaging spectroscopy.

Between 1 and 2 million women in the United States have silicone breast implants. Complications include capsular contracture and calcification and possibly connective tissue diseases such as scleroderma and rheumatoid arthritis, a subject of some controversy. In order to accurately assess the role of silicone in any histopathologic change, it is necessary to confirm its presence and to identify other foreign materials in the capsular tissue. Although light microscopy is used to visualize regions of tissue containing foreign inclusions, their chemical identity can only be determined using analytical techniques such as infrared or Raman microscopy. However, these conventional microprobe techniques record spectra only at single points and require an a priori knowledge of the locations of the inclusion to be probed. To significantly extend the capabilities of both infrared spectroscopy and optical microscopy, we have developed a new infrared imaging system that completely integrates these two methods. In this manuscript we highlight the ability of the technique to screen rapidly and to determine accurately the presence, size and chemical composition of silicone gel inclusions in human breast tissue.

Breast↗

Raman chemical imaging: histopathology of inclusions in human breast tissue.

High-definition Raman chemical imaging microscopy is applied to the histopathological characterization of biopsied human breast tissue containing foreign polymer inclusions. The polymer material is found in a patient with a history of silicone implant breast reconstructive surgery. Silicone implants are, on occasion, anchored to the soft tissues of the chest with polyester patches. In the case studied here, the polyester anchors were incorporated into the patient's fibrous tissue surrounding the implant. High-definition Raman chemical imaging provides molecular-specific image contrast in the complex breast tissue matrix without the use of stains or dyes. This is the first example in which Raman spectroscopic imaging microscopy has been applied to pathology. A goal of this and future studies is to complement traditional histopathologic diagnoses of disease states utilizing vibrational spectroscopic imaging techniques.

Breast↗

Lipid-induced conformational changes of an integral membrane protein: an infrared spectroscopic study of the effects of Triton X-100 treatment on the purple membrane of Halobacterium halobium ET1001.

Exposure of purple membrane from Halobacterium halobium to sublytic concentrations of Triton X-100 results in significant changes in the bacteriorhodopsin (BR) photocycle (Mukhopadhyay et al., 1994). Infrared spectra of purple membrane samples exposed briefly to Triton indicate that this change in protein function accompanies the preferential release of purple membrane glycolipids and squalenes, an association of Triton with purple membrane, and a perturbation of specific lipid headgroup interactions within the membrane. Specifically, the bilayer alterations induced by Triton entail a disruption of lipid headgroup hydrogen bonding in addition to protein conformational changes involving a loss in beta-turn and alphaII-helical structures in BR. We propose that the purple membrane glycolipids and squalenes are critical for the normal functioning of the BR photocycle and that perturbations of these lipids cause the profound photocycle changes induced by exposure to Triton. Lipid reconstitution studies demonstrated that although several of the infrared spectral parameters characteristic of the structural changes induced by Triton were reversed, the photocycle characteristics of BR in native purple membrane were not regained. The observed changes in the vibrational spectra induced by lipid-mediated bilayer perturbations suggest a useful approach for clarifying structure-function relationships of intrinsic membrane proteins exhibiting transmembrane helices.

Bacteriorhodopsins↗

The design and implementation of a high-fidelity Raman imaging microscope.

We describe a Raman imaging microscope that produces high-fidelity, large format Raman images and Raman spectra from samples as small as 1 micron in size. Laser illumination is delivered to the object by means of an infinity corrected microscope objective, either by a galvanometer scanning system or a widefield fibre optic. Wavelength selection of Raman scattered emission is achieved by an acousto-optic tunable filter (AOTF), which maintains image fidelity and provides either continuous or random wavelength selection. The collimated AOTF output is imaged first by a tube lens and then by a projection lens onto a cooled silicon CCD array. Instrument features, including factors that determine the system's spatial and spectral resolution, and design considerations are discussed in detail. Images and spectra of test objects and samples that demonstrate the capability of this imaging spectrometer are presented. The potential of intrinsic chemical imaging is discussed in terms of its use in the analyses of a variety of chemical and biological samples.

Microscopy↗

Fourier transform spectroscopic imaging using an infrared focal-plane array detector.

A powerful new mid-infrared spectroscopic chemical imaging technique combining step-scan Fourier transform Michelson interferometry with indium antimonide focal-plane array (FPA) image detection is described. The coupling of an infrared focal-plane array detector to an interferometer provides an instrumental multiplex/multichannel advantage. Specifically, the multiple detector elements enable spectra at all pixels to be collected simultaneously, while the interferometer portion of the system allows all the spectral frequencies to be measured concurrently. With this method of mid-infrared spectroscopic imaging, the fidelity of the generated spectral images is limited only by the number of pixels on the FPA detector, and only several seconds of starting time is required for spectral image acquisition. This novel, high-definition technique represents the future of infrared chemical imaging analysis, a new discipline within the chemical and material sciences, which combines the capability of spectroscopy for molecular analysis with the power of visualization. In particular, chemical imaging is broadly applicable for noninvasive, molecular characterization of heterogeneous materials, since all solid-state materials exhibit chemical nonuniformity that exists either by design or by development during the course of material preparation or fabrication. Imaging, employing Raman and infrared spectroscopy, allows the precise characterization of the chemical composition, domain structure, and chemical architecture of a variety of substances. This information is often crucial to a wide range of activities, extending from the fabrication of new materials to a basic understanding of biological samples. In this study, step-scan imaging principles, instrument design details, and infrared chemical imaging results are presented. Since the prospect of performing high-resolution and high-definition mid-infrared chemical imaging very rapidly has been achieved with the step-scan approach, the implications for the chemical analysis of materials are many and varied.

Image Processing, Computer-Assisted↗

Combination of potentiometry and resonance Raman spectroscopy for the analysis of a redox protein.

This paper describes apparatus and procedures for combining resonance Raman and optical absorption spectroscopies with potentiometry for the study of redox-active heme proteins. A specially designed anaerobic titration cell is described which allows for the laser excitation of the sample and the monitoring of both Raman scattered light and directly transmitted light from an optical source. New procedures for utilization of A/D and D/A converters on a standard I/O computer card are described, which allow for computer-controlled potentiometry and coulometry. The system was tested with cytochrome c, a well-characterized respiratory protein. The correct values for the midpoint potential and electron number of the Nernst equation were obtained both by the optical absorption and resonance Raman measurements.

Cytochrome c Group↗

Bilayer packing characteristics of mixed chain phospholipid derivatives: Raman spectroscopic and differential scanning calorimetric studies of 1-stearoyl-2-capryl-sn-glycero-3-phosphocholine (C(18):C(10)PC) and 1-stearoyl-2-capryl-sn-glycero-3-phospho-N-trimethylpropanolamine (C(18):C(10)TMPC).

Raman spectroscopy and high-sensitivity differential scanning calorimetry (DSC) were used to compare the effects of headgroup conformation on the acyl chain packing arrangements in two highly asymmetric phosphatidylcholine (PC) analogues, 1-stearoyl-2-capryl-sn-glycero-3-phosphocholine (C(18):C(10)PC) and a polar headgroup derivative of C(18):C(10)PC, 1-stearoyl-2-capryl-sn-glycero-3-phospho-N-trimethylpropanolami ne (C(18):C(10)TMPC), which contains an additional methylene group within the choline moiety; namely, -P-O-(CH2)3-N(CH3)3. The C(18):C(10)TMPC headgroup exhibits an extended trans conformation which is independent of bilayer phase. A comparison of gel phase spectral order parameters of the two lipid species indicates a mixed interdigitated state characteristic of three chains per headgroup for C(18): C(10)TMPC. A more intermolecularly ordered liquid crystalline phase is observed, however, for the C(18):C(10)TMPC bilayers. The phase transition cooperative unit size estimated for the C(18):C(10)PC bilayers (approximately 140 molecules per unit) is about 7-fold greater than that for the C(18):C(10)TMPC dispersions (approximately 20 molecules per unit). We suggest that the extended headgroup for C(18):C(10)TMPC induces a slight tilt in the gel phase packing arrangements for the acyl chains, which may persist in the partially interdigitated liquid crystalline phase bilayer. Macroscopically, tighter packed multilamellar dispersions of C(18):C(10)TMPC occur for systems prepared first in the presence of a higher ionic strength medium. The stacked bilayers may then be transferred to a lower ionic strength environment without loss of their more closely packed adjacent lamellae.

Calorimetry, Differential Scanning↗

Resonance Raman and optical spectroscopic monitoring of heme a redox states in cytochrome c oxidase during potentiometric titrations.

Resonance Raman spectroscopy is used to monitor the redox state of heme a and heme a3 centers in cyanide-inhibited and native cytochrome oxidase during potentiometric titrations. Specific vibrational modes are resolved for each reduced heme with 441.6-nm excitation while oxidized species show vanishingly small Raman intensities. The voltage dependencies of the Raman intensities of reduced heme a and reduced heme a3 modes are quantitatively measured and used to extract heme a and a3 midpoint potentials. In the cyanide-bound enzyme, in which heme a3 remains in the oxidized state, the Raman data indicate that heme a centers exhibit complex Nernstian behavior with two Em values near 350 and 260 mV. In the native enzyme, this resonance Raman-potentiometric method reveals significantly different redox behavior for the two hemes. Heme a centers are described by two effective Em values near 350 and 220 mV, while heme a3 centers have lower Em values near 260 and 200 mV. Singular value decomposition analysis of optical spectral changes supports the Raman data. These results are in contrast to models of cytochrome oxidase redox behavior in which heme a and heme a3 are thought to have essentially identical midpoint potentials.

Animals↗

Near infrared spectral changes of cytochrome aa3 during potentiometric titrations.

Singular value decomposition (SVD) was used to deconvolute the spectral changes occurring in the near infrared region during potentiometric titrations of cytochrome aa3. Overall oxidized minus reduced difference spectra revealed a broad absorbance feature centered near 830 nm with an apparent Em near 250 mV. However, SVD did not isolate any spectral species with an absorbance centered near 830 nm. It was found that the spectral changes occurring in the wavelength region from 650 to 950 nm were associated mainly with cytochromes a and a3. It was concluded that the absorbance at 830 nm should not be used as an independent measure of the concentration of CuA in cytochrome aa3.

Animals↗

Interactions of model human pulmonary surfactants with a mixed phospholipid bilayer assembly: Raman spectroscopic studies.

The temperature dependence and acyl chain packing properties of the binary lipid mixtures of dipalmitoylphosphatidylcholine-d62 (DPPC-d62)/dipalmitoylphosphatidylglycerol (DPPG) multilayers, reconstituted with two synthetic peptides for modeling the membrane behavior of the SP-B protein associated with human pulmonary surfactant, were investigated by vibrational Raman spectroscopy. The synthetic peptides consisted of 21 amino acid residues representing repeating charged units of either lysine or aspartic acid separated by hydrophobic domains consisting of four leucines (KL4 or DL4, respectively). These peptides were designed to mimic the alternating hydrophobic and hydrophilic sequences defining the low molecular weight SP-B protein. Raman spectroscopic parameters consisting of integrated band intensities, line widths, and relative peak height intensity ratios were used to probe the bilayer order/disorder characteristics of the liposomal perturbations reflected by the reconstituted membrane assemblies. Temperature profiles derived from the various Raman intensity parameters for the 3100-2800-cm-1 carbon-hydrogen (C-H) and the 2000-2300-cm-1 carbon-deuterium (C-D) stretching mode regions, spectral intervals representative of acyl chain vibrations, reflected lipid reorganizations specific to peptide interactions with either the DPPC-d62 or DPPG component of the liposome. For the multilamellar surfactant systems composed of either KL4 or DL4 reconstituted with the binary DPPG/DPPC-d62 lipid mixture, the breadth of the gel to liquid crystalline phase transition temperatures TM, defined by acyl chain C-H and C-D stretching mode order/disorder parameters, increased from about 1 degree C in the peptide-free systems to over 10 degrees C. This breadth in TM indicates an increased lipid disorder and a distinct noncooperative chain melting process for the model liposomes. In comparing the interactions of the synthetic peptides with DPPG/DPPC mixtures and with DPPC liposomes alone, the negatively charged DL4 peptide perturbs the DPPG component of the lipid mixture more strongly than the DPPC-d62 component; moreover, the DL4 peptide disrupts the structure of the DPPG lipid domains in the binary mixture to a greater extent than the KL4 peptide. The microdomain heterogeneity of the binary lipid mixture arising from lipid-peptide interactions is discussed in terms of the Raman spectral properties of the multilayers. The Raman data in conjunction with previous bubble surfactometer and animal studies (Cochrane & Revak, 1991) suggest that lipid domain structures are present in functional surfactants and that the dynamic bilayer microheterogeneity induced by the surfactant peptide or protein is essential for pulmonary mechanics.

1,2-Dipalmitoylphosphatidylcholine↗