PubMed Health⌕ Search

Biomedical subjects

I Waite

Publications and source records attributed to I Waite.

8 recordsLinked to original sources

Tip60 is a nuclear hormone receptor coactivator.

The androgen receptor (AR) is a member of the nuclear hormone receptor superfamily. Recent work in this field has been focused upon defining the mechanisms of transcriptional control exacted by members of this superfamily. Using a COOH-terminal region of the human AR in a yeast two-hybrid screen, we have identified Tip60 as an AR-interacting protein. In this report, we show that Tip60, which was originally identified as a coactivator for the human immunodeficiency virus TAT protein, can enhance AR-mediated transactivation in a ligand-dependent manner in LNCaP and COS-1 cell lines. In addition, our experiments show that Tip60 can also enhance transactivation through the estrogen receptor and progesterone receptor in a ligand-dependent manner; thus identifying Tip60 as a nuclear hormone receptor coactivator. Our studies also demonstrate that Tip60 co-immunoprecipitates with the full-length AR in vitro and that, in our system, Tip60 enhances transactivation to levels observed with the coactivators steroid receptor coactivator 1, p300, and CREB-binding protein. The importance of such proteins in enhancing nuclear hormone receptor-mediated transcriptional activation is widely accepted, and this work suggests that Tip60 may have an equally important role to play.

Acetyltransferases↗

Androgen regulation of ornithine decarboxylase in human prostatic cells identified using differential display.

Androgens are essential for normal prostate physiology and have a permissive role in the development and progression of prostate cancer. Using the mRNA differential display technique, ornithine decarboxylase (ODC) was identified to be up-regulated by androgens in human prostatic LNCaP cells. On Northern analysis, the induction of ODC expression by 10 nM androgen was rapid and continued up to 48 h exposure with a maximum 6.3-fold up-regulation. The anti-androgen Casodex inhibited the androgen-induced up-regulation of ODC, whereas the protein synthesis inhibitor cycloheximide did not. Together these data suggest that regulation is mediated through the androgen receptor protein and does require secondary protein synthesis, respectively. The kinetics of induction of ODC were almost identical to those of prostate specific antigen. Taken together these data suggest that ODC is directly regulated by androgens in LNCaP cells.

Base Sequence↗

Tissue reactions to biodegradable and non-degradable membranes placed transcutaneously in rats, observed longitudinally over a period of 4 weeks.

The aim of this study was to observe the tissue responses to a number of membrane materials processed for use in guided tissue regeneration at different time periods. Non-degradable Gore-Tex PTFE membrane and degradable polylactic acid (PLA) membranes were placed transcutaneously in surgical incisions made in the dorsum of rats. The tissue responses to these materials were observed histologically at 3 days, 1 week and 4 weeks after placement. A wide variation in the tissue responses to both materials was evident at each time period. These variations could not be attributed to different rates of healing over time, but rather to more complex factors. These factors may include differences in host responses between different animals, local factors pertaining to specific site variations, physical characteristics of the materials like surface texture, and contamination from the wound surface. Neither membrane material was found to be totally satisfactory. The PLA membranes were well tolerated by the tissues but they were unevenly absorbed within 2 weeks of placement. The Gore-Tex PTFE membranes, however, were associated with prolonged acute inflammatory infiltrate throughout the duration of the study, indicating that they were less well tolerated by the tissues than the PLA materials. As the healing characteristics of tissues are complex and highly variable, and as neither the non-degradable PTFE or degradable PLA membranes demonstrated ideal tissue responses, it is concluded that variations in clinical responses to these materials used in regeneration techniques must be anticipated.

Absorption↗

Histological evaluation of biodegradable and non-degradable membranes placed transcutaneously in rats.

The aim of this study was to assess histologically the response to membrane materials that might be used for guided tissue regeneration procedures, using a transcutaneous model on the dorsal surface of the rat. The materials included expanded polytetrafluoroethylene (PTFE) membrane (Gore-Tex), PTFE Millipore filter, biodegradable polylactic acid (PLA) and polyhydroxybutyrate/polyhydroxyvalerate copolymer membranes. 70 implants were placed in 10 rats under general anaesthesia. At 2 weeks after the operative procedure, the specimens were assessed histologically for the composition of the tissue surrounding the material, the types of cell in the infiltrate and the degree of absorption particularly in the superficial tissues. PTFE was associated with greater epithelial downgrowth and a mainly polymorphonuclear infiltrate. PLA showed a high incidence of absorption, with a mainly monocytic infiltrate. Considerable variation was found between these extremes. It was concluded that the healing responses associated with the membranes were complex and varied, and further work is required to establish the factors which govern the variation in the healing response. The findings are of relevance to regenerative procedures which rely on the guiding influence of artificial membranes on the healing tissues. The PLA material was well tolerated and was gradually absorbed. Further research may enable this material to form the basis of a one stage guided tissue regeneration procedure.

Absorption↗

A microcomputer system for the analysis of dental radiographs.

A system for the digital storage and computer analysis of dental radiographs is described. The system is based on popular microcomputer, of a type commonly used for other purposes in general dental practice. The analysis system includes methods to compensate for variations due to exposure and development in serial radiographs. Interactive software allows a detailed analysis of the radiograph, producing qualitative and quantitative data for diagnosis and monitoring. An example of its application is given.

Alveolar Process↗