PubMed Health⌕ Search

Biomedical subjects

I-Wei Chen

Publications and source records attributed to I-Wei Chen.

7 recordsLinked to original sources

Prevention of oxidative degradation of polyurethane by covalent attachment of di-tert-butylphenol residues.

Polyurethane (PU) components of cardiovascular devices are subjected to oxidation-initiated surface degradation, which leads to cracking and ultimately device failure. In the present study, we investigated a novel bromoalkylation chemical strategy to covalently attach the antioxidant, di-tert-butylphenol (DBP), and/or cholesterol (Chol) to the PU urethane nitrogen groups to hypothetically prevent oxidative degradation. These experiments compared PU, PU-DBP, PU-Chol, and PU-Chol-DBP. A series of comparative oxidative degradation studies involved exposing PU samples (modified and unmodified) to H2O2-CoCl2 for 15 days at 37 degrees C, to cause accelerated oxidative degradation. The extent and effects of degradation were assessed by attenuated total reflectance Fourier transformation infrared spectroscopy (FTIR), scanning electron microscopy (SEM), surface contact angle measurements, and mechanical testing. Both the Chol and DBP modification conferred significant resistance to oxidation related changes compared to unmodified PU per FTIR and SEM results. SEM demonstrated cavitation only in unmodified PU. However, contact angle analysis showed significant oxidation-induced changes only in the Chol-modified PU formulations. Most importantly, uniaxial stress-strain testing revealed that only PU-DBP demonstrated bulk elastomeric properties that were minimally affected by oxidation; PU, PU-Chol, PU-Chol-DBP showed marked deterioration of their stress-strain properties following oxidation. In conclusion, these results demonstrate that derivatizing PU with DBP confers significant resistance to oxidative degradation compared with unmodified PU.

Butanes↗

Bisphosphonate-mediated gene vector delivery from the metal surfaces of stents.

The clinical use of metallic expandable intravascular stents has resulted in improved therapeutic outcomes for coronary artery disease. However, arterial reobstruction after stenting, in-stent restenosis, remains an important problem. Gene therapy to treat in-stent restenosis by using gene vector delivery from the metallic stent surfaces has never been demonstrated. The present studies investigated the hypothesis that metal-bisphosphonate binding can enable site-specific gene vector delivery from metal surfaces. Polyallylamine bisphosphonate (PAA-BP) was synthesized by using Michael addition methodology. Exposure to aqueous solutions of PAA-BP resulted in the formation of a monomolecular bisphosphonate layer on metal alloy surfaces (steel, nitinol, and cobalt-chromium), as demonstrated by x-ray photoelectron spectroscopy. Surface-bound PAA-BP enabled adenoviral (Ad) tethering due to covalent thiol-binding of either anti-Ad antibody or a recombinant Ad-receptor protein, D1. In arterial smooth muscle cell cultures, alloy samples configured with surface-tethered Ad were demonstrated to achieve site-specific transduction with a reporter gene, (GFP). Rat carotid stent angioplasties using metal stents exposed to aqueous PAA-BP and derivatized with anti-knob antibody or D1 resulted in extensive localized Ad-GFP expression in the arterial wall. In a separate study with a model therapeutic vector, Ad-inducible nitric oxide synthase (iNOS) attached to the bisphosphonate-treated metal stent surface via D1, significant inhibition of restenosis was demonstrated (neointimal/media ratio 1.68 +/- 0.27 and 3.4 +/- 0.35; Ad-iNOS vs. control, P < 0.01). It is concluded that effective gene vector delivery from metallic stent surfaces can be achieved by using this approach.

Adenoviridae↗

Cholesterol-derivatized polyurethane: characterization and endothelial cell adhesion.

Endothelialization of synthetic surfaces has been challenging with limited success thus far. We investigated the hypothesis that covalent attachment of cholesterol to polyurethane via the urethane nitrogen groups would create a high-affinity surface for attachment and adhesion of endothelial cells. Cholesterol was covalently bound to the polyether polyurethane, Tecothane, by first derivatizing the polyurethane nitrogen groups with bromoalkyl side chains, followed by reacting mercapto-cholesterol to the bromoalkyl sites. Cholesterol-modified polyurethane demonstrated a qualitatively smoother surface per atomic force microscopy than nonmodified and increased surface energy (contact angle measurements) compared with unmodified polyurethane. Cell attachment assays showed a significantly greater number of attached bovine arterial endothelial cells (p = 0.0003) after 45 min of seeding on cholesterol-modified polyurethane versus unmodified polyurethane. Bovine arterial endothelial cells cultivated on cholesterol-modified Tecothane showed significantly greater levels of cell retention compared with unmodified Tecothane when exposed to arterial level shear stress for 2 h (25 dynes/cm2) with 90.0 +/- 6.23% cells remaining adherent compared with unmodified polyurethane, 41.4 +/- 11.7%, p = 0.0070. Furthermore, ovine endothelial precursors, obtained as blood outgrowth endothelial cells, were seeded on cholesterol-modified polyurethane and exposed to 25 dynes/cm2 shear conditions for 2 h, with the retention of 90.30 +/- 3.25% of seeded cells versus unmodified polyurethane, which retained only 4.56 +/- 0.85% (p < 0.001). It is concluded that covalently linking cholesterol to polyurethane results in improved material properties that permit increased endothelial cell retention compared with unmodified polyurethane.

Animals↗

Dynamic Kerr effect and the spectral weight transfer of the manganites.

Pump-probe Kerr spectroscopy uncovers surface magnetic dynamics in Pr0.67Ca0.33MnO3 that are undetected by established methods based on optical spectral weight transfer. The connection between spin and charge dynamics in the colossally magnetoresistive manganites may thus be weaker than previously thought. Important differences from conventional ferromagnetic metals manifest as long-lived, magneto-optical coupling transients, which may be generic to all manganites.

Journal Article↗

Iron oxide nanoparticles as magnetic resonance contrast agent for tumor imaging via folate receptor-targeted delivery.

RATIONALE AND OBJECTIVE: Targeted delivery is a highly desirable strategy for diagnostic imaging because of enhanced efficacy and reduced dosage/toxicity. Receptor-targeting was used to deliver contrast-producing superparamagnetic iron oxide (IO) nanoparticle to receptor-expressing tumors for in vivo magnetic resonance (MR) imaging. MATERIALS AND METHODS: Nanometer-sized, dextran-coated (maghemite) IO particles were prepared by a precipitation method. They were tethered with N-hydroxysuccinimide-folate and fluorescence isothiocyanate (FITC). For in vitro study of delivery specificity and efficiency, KB cells, a human nasopharyngeal epidermal carcinoma cell line expressing surface receptors for folic acid, were used as positive targets, and A549 cells, a human lung carcinoma cell line which lacks folate receptors, were used as negative control targets. In vivo MR images were obtained using mouse models with subcutaneous tumor xenografts grown from implanted KB cells. RESULTS: Internalization of nanoparticles into targeted cells only occurred when IO was conjugated to folate and when the folate receptors are available and accessible on the cells. The endocytosis was efficient and rapid, as 97.5% KB cells cultured with folate-FITC-IO showed FITC uptake after 1 hour of incubation. In in vivo MR imaging, an average intensity decrease of 38% was observed from precontrast to postcontrast images of the tumor, which was about three times the intensity decrease observed at a non-tumor-bearing muscle. CONCLUSION: Successful in vivo MR imaging of folate receptor-expressing tumors targeted by IO nanoparticles was demonstrated for the first time.

Animals↗

Surface-modified silica colloid for diagnostic imaging.

A method of preparing nanometer-sized oxide colloids suitable as substance carriers for size-sensitive diagnostic imaging and other biomedical applications is described. The nanometer-sized silica particles prepared by the Stober process were reacted with silane to obtain amine-terminated colloidal surfaces under aqueous conditions. The surface-modified colloids can be further treated to combine or conjugate with imaging agents and other diagnostic or therapeutic substances. The water-stable colloidal carriers are spherical and have a narrow size distribution that can be controlled to range from 10 to 200 nm.

Colloids↗

Spinel sialons.

Explore the source record for details and available documents.

Journal Article↗