PubMed Health⌕ Search

Biomedical subjects

Iacopo Carbone

Publications and source records attributed to Iacopo Carbone.

11 recordsLinked to original sources

Effects of levosimendan on right ventricular afterload in patients with acute respiratory distress syndrome: a pilot study.

OBJECTIVE: Acute respiratory distress syndrome (ARDS) is frequently associated with increased pulmonary vascular resistance and thus with systolic load of the right ventricle. We hypothesized that levosimendan, a new calcium sensitizer with potential pulmonary vasodilator properties, improves hemodynamics by unloading the right ventricle in patients with ARDS. DESIGN: Prospective, randomized, placebo-controlled, pilot study. SETTING: Twenty-two-bed multidisciplinary intensive care unit of a university hospital. PATIENTS: Thirty-five patients with ARDS in association with septic shock. INTERVENTIONS: Patients were randomly allocated to receive a 24-hr infusion of either levosimendan 0.2 microg/kg/min (n = 18) or placebo (n = 17). Data from right heart catheterization, cardiac magnetic resonance, arterial and mixed venous oxygen tensions and saturations, and carbon dioxide tensions were obtained before and 24 hrs after drug infusion. MEASUREMENTS AND MAIN RESULTS: At a mean arterial pressure between 70 and 80 mm Hg (sustained with norepinephrine infusion), levosimendan increased cardiac index (from 3.8 +/- 1.1 to 4.2 +/- 1.0 L/min/m) and decreased mean pulmonary artery pressure (from 29 +/- 3 to 25 +/- 3 mm Hg) and pulmonary vascular resistance index (from 290 +/- 77 to 213 +/- 50 dynes/s/cm(5)/m(2); each p < .05). Levosimendan also decreased right ventricular end-systolic volume and increased right ventricular ejection fraction (p < .05). In addition, levosimendan increased mixed venous oxygen saturation (from 63 +/- 8 to 70 +/- 8%; p < .01). CONCLUSIONS: This study provides evidence that levosimendan improves right ventricular performance through pulmonary vasodilator effects in septic patients with ARDS. A large multiple-center trial is needed to investigate whether levosimendan is able to improve the overall prognosis of patients with sepsis and ARDS.

Aged↗

ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings.

Our objective was to retrospectively evaluate the ability of multidetector-row computed tomography (MDCT) to detect previous myocardial infarctions (MIs) and to correlate necrosis with the status of coronary arteries supplying the infarcted territory. After having clinically evaluated 187 patients referred for ECG-gated MDCT of the coronary arteries, 30 previous MIs were identified in 29 patients (9 recent and 21 chronic). MDCT data were evaluated qualitatively and quantitatively by measuring attenuation values and wall thickness within the infarcted region and normal adjacent myocardium. Each MI was also assigned to the distribution territory of a coronary vessel, and morphological data were combined with MDCT angiographic findings. MDCT was able to detect 25/30 MIs showing an overall sensitivity and specificity of 83 and 91%, respectively. Quantitative analysis revealed a statistically significant difference in attenuation values between normal and infarcted regions (38.9+/-14 HU vs. 104.0+/-16 HU). Regional wall thinning was observed in chronic MIs (4.1+/-2 mm vs. 10.5+/-3.8 mm), and not in patients with recent event (7.9+/-1.6 mm vs 9.1+/-4 mm). In 22/25 cases, MDCT angiographic findings showed the presence of suspicious critical lumen narrowing (n=3), previous coronary stenting (n=14) and surgical revascularization (n=5) in the infarct-related coronary. During a single examination, MDCT might provide comprehensive imaging of MI offering a combined morphological and angiographic assessment.

Adult↗

Multidetector computed tomography of the coronary arteries.

Over the past decades, the feasibility of non-invasive coronary imaging has been explored using different modalities, such as magnetic resonance and electron beam computed tomography. Despite encouraging initial results, neither technique is yet considered suitable for routine clinical use. Recent developments in multidetector computed tomography have expanded the potential of contrast-enhanced spiral computed tomography coronary angiography. Promising results have been published with the use of 4-slice spiral computed tomography; however, cardiac motion and calcium deposits in the artery wall rendered a substantial number of scans inadequate for interpretation. Recently, a new generation of scanners, equipped with more and thinner detector rows (8 and 16 detectors) and an increased rotation speed, have been introduced. These technical advances will have a significant impact on cardiac imaging: at an increased gantry rotation rate, up to 32 slices can be acquired in 1 s. The improved spatial and temporal resolutions have led to the opportunity of acquiring high-quality images of the entire heart within a single breath-hold.

Calcinosis↗

Hepatocellular carcinoma: detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis.

PURPOSE: To evaluate whether the use of two arterial phase image acquisition series, when combined with portal venous phase imaging at multi-detector row helical computed tomography (CT), would be superior enough to use of a single arterial phase image acquisition series to warrant the increased radiation dose. MATERIALS AND METHODS: Multi-detector row CT was performed in 77 patients with 140 foci of hepatocellular carcinoma (HCC). A triple-phase protocol that included an early arterial phase, a late arterial phase, and a portal venous phase was performed. Images were analyzed separately by three radiologists to document the presence and number of HCC nodules. Separate reading sessions were performed for images from the early arterial phase, images from the late arterial phase, images from both arterial phases combined, and images from all three phases. Sensitivity and positive predictive values were calculated for each reading session. RESULTS: The average sensitivity and positive predictive values, respectively, for the detection of HCC were 48.5% and 96.4% for early arterial phase images, 87.1% and 94.0% for late arterial phase images, 87.1% and 94.0% for images from both arterial phases, and 88.5% and 93.4% for images from all three phases. Analysis of images from both arterial phases together yielded no improvement in either sensitivity or positive predictive value compared with analysis of late arterial phase images alone. Analysis of the combination of late arterial and portal venous phase images resulted in the highest sensitivity value. CONCLUSION: The acquisition of images during two arterial contrast phases does not provide additional benefit over timed conventional biphasic CT technique.

Aged↗

MR imaging of the small bowel using polyethylene glycol solution as an oral contrast agent in adults and children with celiac disease: preliminary observations.

OBJECTIVE: The purpose of our report is to describe morphologic abnormalities of the small bowel in a population of patients with known celiac disease using MR imaging with polyethylene glycol solution as an oral contrast agent. CONCLUSION: Polyethylene glycol-enhanced MR imaging is a noninvasive (no ionizing radiation is used), feasible, and reproducible imaging technique in both adult and pediatric populations. Findings on polyethylene glycol-enhanced MR imaging, similar to those of conventional barium studies, may suggest a diagnosis of celiac disease because the technique can not only reveal intestinal involvement but also show extraintestinal findings.

Administration, Oral↗

Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study.

The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer.

Adenocarcinoma↗

Detection of colorectal lesions with virtual computed tomographic colonography.

BACKGROUND: The aim of our study was to compare the performance of virtual computed tomographic colonography with that of conventional colonoscopy in a blinded, prospective study in 165 patients with suspected colorectal lesions. METHODS: There were 165 patients, all referred for conventional colonoscopy, who underwent preliminary virtual computed tomographic colonography. Computed tomograhic images of all suspected lesions were analyzed and subsequently compared with conventional colonoscopy findings. RESULTS: There were 30 colorectal cancers and 37 polyps identified at conventional colonoscopy. Virtual computed tomographic colonography correctly detected all cancers, as well as 11 of 12 polyps of 10 mm in diameter or larger (sensitivity, 92%); 14 of 17 polyps between 6 and 9 mm (sensitivity, 82%); and 4 of 8 polyps of 5 mm or smaller (sensitivity, 50%). The per-patient sensitivity and specificity were 92% and 97%, respectively. CONCLUSIONS: Virtual computed tomographic colonography has a diagnostic sensitivity similar to that of conventional colonoscopy for the detection of colorectal lesions larger than 6 mm in diameter.

Adult↗

Stool tagging applied in thin-slice multidetector computed tomography colonography.

OBJECTIVE: To compare thin-slice multidetector computed tomography colonography (CTC) that uses stool tagging with colonoscopy. METHOD: One hundred fifty patients scheduled for colonoscopy underwent high-resolution CTC. An iodinated contrast agent was added to the preparation to tag the residual colonic fluid and stool. The effect of fluid tagging was assessed first. Sensitivity and specificity were calculated for two independent readers. In addition, values were recalculated separately for the first and last 75 patients. RESULTS: Tagging was optimal in 95.3% of the cases, and reader confidence was high. Sensitivities were 64.1%-66.7% (for the 2 readers) for 5- to 9-mm polyps and 91.7% for larger polyps. The overall specificity was 94.2% and 95%. Sensitivity improved during the study for both 5- to 9-mm polyps (from 54.2%-58.3% to 80%) and polyps larger than 9 mm (from 50% to 100%). Specificity changed nonuniformly. CONCLUSION: The combination of fluid tagging and high-resolution scanning in CTC showed high sensitivity and specificity, especially concerning sensitivity for polyps of 10 mm and larger.

Colon↗