PubMed Health⌕ Search

Biomedical subjects

Ian E Pacey

Publications and source records attributed to Ian E Pacey.

2 recordsLinked to original sources

Evidence for a learning effect in short-wavelength automated perimetry.

PURPOSE: To document the magnitude of any learning effect for short-wavelength automated perimetry (SWAP) in patients with either ocular hypertension (OHT) or open-angle glaucoma (OAG) who are experienced in standard automated perimetry (SAP). DESIGN: Experimental study. PARTICIPANTS: Thirty-five patients (22 with OHT and 13 with OAG) who had previously undergone at least 3 threshold SAP visual field examinations with the Humphrey Field Analyzer (HFA; Carl Zeiss Meditech Inc., Dublin, CA), and 9 patients with OHT who had not previously undertaken any form of perimetry. METHODS: Each patient attended for SWAP on 5 occasions, each separated by 1 week. At each visit, both eyes were examined using Program 24-2 of the HFA; the right eye was always examined before the left eye. MAIN OUTCOME MEASURES: (1) Change over the 5 examinations, in each eye, of the visual field indices Mean Deviation (MD), Short-term Fluctuation (SF), Pattern Standard Deviation (PSD), and Corrected Pattern Standard Deviation. (2) Change in each eye between Visits 1 and 5 in proportionate Mean Sensitivity (pMS) for the central annulus of stimulus locations compared with that for the peripheral annulus thereby determining the influence of stimulus eccentricity on any alteration in sensitivity. (3) Change between Visits 1 and 5 in the number and magnitude of the Pattern Deviation (PD) probability levels associated with any alteration in sensitivity. RESULTS: The MD, SF, and PSD each improved over the 5 examinations (each at P<0.001). The improvement in pMS between Visits 1 and 5 was greater for the peripheral annulus than for the central annulus by approximately twofold for the patients with OAG. Considerable variation was present between patients, within and between groups, in the number of locations exhibiting an improving sensitivity between Visits 1 and 5 by 1 or more PD probability levels. CONCLUSIONS: Care should be taken to ensure that, during the initial examinations, apparent field loss with SWAP in patients exhibiting a normal field by SAP is not the result of inexperience in SWAP. Apparently deeper or wider field loss in the initial examinations with SWAP compared with that exhibited by SAP in OAG also may arise from inexperience in SWAP.

Adult↗

Nonveridical visual perception in human amblyopia.

PURPOSE: Amblyopia is a developmental disorder of spatial vision. There is evidence to suggest that some amblyopes misperceive spatial structure when viewing with the affected eye. However, there are few examples of these perceptual errors in the literature. This study was an investigation of the prevalence and nature of misperceptions in human amblyopia. METHODS: Thirty amblyopes with strabismus and/or anisometropia participated in the study. Subjects viewed sinusoidal gratings of various spatial frequencies, orientations, and contrasts. After interocular comparison, subjects sketched the subjective appearance of those stimuli that had nonveridical appearances. RESULTS: Nonveridical visual perception was revealed in 20 amblyopes ( approximately 67%). In some subjects, misperceptions were present despite the absence of a deficit in contrast sensitivity. The presence of distortions was not simply linked to the depth of amblyopia, and anisometropes were affected as well as those with strabismus. In most cases, these spatial distortions arose at spatial frequencies far below the contrast detection acuity cutoff. Errors in perception became more severe at higher spatial frequencies, with low spatial frequencies being mostly perceived veridically. The prevalence and severity of misperceptions were frequently found to depend on the orientation of the grating used in the test, with horizontal orientations typically less affected than other orientations. Contrast had a much smaller effect on misperceptions, although there were cases in which severity was greater at higher contrasts. CONCLUSIONS: Many types of misperceptions documented in the present study have appeared in previous investigations. This suggests that the wide range of distortions previously reported reflect genuine intersubject differences. It is proposed that nonveridical perception in human amblyopia has its origins in errors in the neural coding of orientation in primary visual cortex.

Adolescent↗