Bypassing the learning curve in permanent seed implants using state-of-the-art technology.

PURPOSE: The aim of this study was to demonstrate, based on clinical postplan dose distributions, that technology can be used efficiently to eliminate the learning curve associated with permanent seed implant planning and delivery. METHODS AND MATERIALS: Dose distributions evaluated 30 days after the implant of the initial 22 consecutive patients treated with permanent seed implants at two institutions were studied. Institution 1 (I1) consisted of a new team, whereas institution 2 (I2) had performed more than 740 preplanned implantations over a 9-year period before the study. Both teams had adopted similar integrated systems based on three-dimensional (3D) transrectal ultrasonography, intraoperative dosimetry, and an automated seed delivery and needle retraction system (FIRST, Nucletron). Procedure time and dose volume histogram parameters such as D90, V100, V150, V200, and others were collected in the operating room and at 30 days postplan. RESULTS: The average target coverage from the intraoperative plan (V100) was 99.4% for I1 and 99.9% for I2. D90, V150, and V200 were 191.4 Gy (196.3 Gy), 75.3% (73.0%), and 37.5% (34.1%) for I1 (I2) respectively. None of these parameters shows a significant difference between institutions. The postplan D90 was 151.2 Gy for I1 and 167.3 Gy for I2, well above the 140 Gy from the Stock et al. analysis, taking into account differences at planning, results in a p value of 0.0676. The procedure time required on average 174.4 min for I1 and 89 min for I2. The time was found to decrease with the increasing number of patients. CONCLUSION: State-of-the-art technology enables a new brachytherapy team to obtain excellent postplan dose distributions, similar to those achieved by an experienced team with proven long-term clinical results. The cost for bypassing the usual dosimetry learning curve is time, with increasing team experience resulting in shorter treatment times.

Brachytherapy↗

A comparison of techniques for simulating set-up error and uncertainty in head and neck IMRT.

We have compared four computational methods for quantifying the effect of set-up error and uncertainty on delivered doses to targets and organs at risk in the intensity modulated radiation therapy treatment of head and neck cancer. These four methods were direct simulation, simple convolution, plus two modified convolution approaches. Discrepancies of up to 20% in the equivalent uniform dose (EUD) between direct simulation and simple convolution were estimated for the relatively superficial parotid gland at a systematic set-up error of 6 mm standard deviation and a random uncertainty of 2 mm standard deviation. Truncated convolution agreed with direct simulation to within 6% for all situations studied. However, of the four methods, only direct simulation can quantify the range of outcomes (EUD) associated with a finite number of courses and fractions. Our results are particularly relevant to the design of dose escalation studies in head and neck cancer.

Computer Simulation↗

A technical evaluation of the Nucletron FIRST system: conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations.

The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dose-rate brachytherapy seed remote afterloader (the seedSelectron), (2) utilizes 3D image reconstruction acquired from electromechanically controlled, nonstepping rotation of the ultrasound probe, (3) integrates the control of a remote afterloader with electromechanical control of the ultrasound probe for integrating the clinical procedure into a single system, and (4) automates the transfer of planning information and seed delivery to improve quality assurance and radiation safety. This automated delivery system is specifically intended to address reproducibility and accuracy of seed positioning during implantation. The FIRST computer system includes two software environments: SPOT PRO and seedSelectron; both are used to facilitate treatment planning and brachytherapy seed implantation from beginning to completion of the entire procedure. In addition to these features, the system is reported to meet certain product specifications for seed delivery positioning accuracy and reproducibility, seed calibration accuracy and reliability, and brachytherapy dosimetry calculations. Consequently, a technical evaluation of the FIRST system was performed to determine adherence to manufacturer specifications and to the American Association of Physicists in Medicine (AAPM) Task Group Reports 43, 53, 56, 59, and 64 and recommendations of the American Brachytherapy Society (ABS). The United States Nuclear Regulatory Commission (NRC) has recently added Licensing Guidance for the seedSelectron system under 10 CFR 35.1000. Adherence to licensing guidance is made by referencing applicable AAPM Task Group recommendations. In general, results of this evaluation indicated that the system met its claimed specifications as well as the applicable recommendations outlined in the AAPM and ABS reports.

Brachytherapy↗

Rapid detection of mecA and nuc genes in staphylococci by real-time multiplex polymerase chain reaction.

A multiplex real-time polymerase chain reaction (RT-PCR) targeting the mecA and nuc genes was developed for the detection of methicillin resistance and identification of Staphylococcus aureus. Novel mecA and nuc primers and fluorescence resonance energy transfer hybridization probes specific for the mecA and nuc genes were evaluated. The assay was performed using the LightCycler system (Roche Molecular Biochemicals, Mannheim, Germany) and evaluated against the traditional gel-based multiplex PCR (PCR-gel) method currently used at Royal Perth Hospital. Clinical isolates (n = 222) and isolates from a culture collection library (n = 206) were tested by both assays in parallel. The RT-PCR assay was 100% sensitive and specific for the detection of methicillin resistance and for the identification of S. aureus when compared with the PCR-gel assay. Results from the RT-PCR assay showed 5 isolates with lower efficiency fluorescence curves for the nuc gene PCR fragment. DNA sequencing showed mutations within the region of the probe-binding sites compared with the reference strain. The results of the RT-PCR assay were available within 2 h. This rapid mecA/nuc RT-PCR assay is a suitable and practical tool for the routine detection of methicillin resistance and identification of S. aureus, which can be easily incorporated into the diagnostic molecular microbiology laboratory work flow.

Bacterial Proteins↗

Functional CT in lung with a conventional scanner: simulations and sampling considerations.

Due to rapid transit times, motion artefacts from breathing and the low signal intensity, functional computed tomography (f-CT) studies in lung tissue remain challenging with conventional CT scanners. The purpose of this study is to examine the accuracy of parameter estimates when performing deconvolution analysis with signals from lung tissue. The effects of partial volume averaging in lung tissue, differing transit times, variable vascular and capillary responses, expected noise levels, differing sampling rate and durations were simulated on a computer. Deconvolution using singular-value decomposition (SVD) analysis was performed for realistic lung signals using published and measured values of the arterial input and noise levels. The accuracy, bias and variance of the estimated residue functions and their associated parameter estimates were evaluated. We find that f-CT signals may be measured and analysed using SVD and other deconvolution approaches. Functional CT signals in the lung may be analysed provided that the rise and fall of the tissue and input curves are well sampled (regardless of sampling rate) and noise levels in the lung ROI tissue are approximately 20 HU or less, even for regions of interest that are mostly occupied by air. Estimates of the mean tissue transit time (MTT) are insensitive to air volume. Other decovolution methods such as fast Fourier transform methods provide more accurate estimates of PBF, whereas SVD approaches provide more accurate estimates of pulmonary blood volume and MTT. F-CT of the lung with a conventional scanner should be possible, when the extra dose is not a consideration.

Computer Simulation↗

A quantitative LightCycler PCR to detect Streptococcus pneumoniae in blood and CSF.

A quantitative real-time PCR targeting the Pneumolysin (ply) gene of Streptococcus pneumoniae was developed for the LightCycler instrument using Fluorescence Resonance Energy Transfer (FRET) probes. All common S. pneumoniae serotypes were detected while other bacteria and viruses were not. The sensitivity was determined to be between one and ten target copies per reaction. The PCR was applied to six CSF and 16 whole blood specimens from 17 patients with laboratory proven invasive pneumococcal disease. One hundred percent of CSF specimens and 69% of whole blood specimens were PCR positive. The bacterial loads were determined to be 7.6 to 6.01 x 10(5) copies/microL for the six CSF specimens, and 0.08 to 5.4 x 10(2) copies/microL for the 16 whole blood specimens. Ninety-seven percent of 30 culture and Gram's stain negative CSF specimens and 100% of 50 normal whole blood specimens were PCR negative. This highly sensitive and specific PCR assay has the potential to provide sufficiently rapid results to improve antibiotic treatment of S.pneumoniae infections, while bacterial load quantitation has opened up exciting possibilities for patient management.

Bacteremia↗