PubMed Health⌕ Search

Biomedical subjects

Ilan E Timor-Tritsch

Publications and source records attributed to Ilan E Timor-Tritsch.

29 records · Page 2Linked to original sources

Two hundred ninety consecutive cases of multifetal pregnancy reduction: comparison of the transabdominal versus the transvaginal approach.

OBJECTIVE: The purpose of this study was to compare the performance of the transabdominal versus the transvaginal route for the multifetal pregnancy reductions. STUDY DESIGN: Two hundred ninety consecutive cases of multifetal pregnancy reduction were reviewed. Two hundred three reductions (70.0%) were done transabdominally; 75 cases (25.9%) were done transvaginally, and 12 cases (4.1%) used both routes. The indications for the transvaginal route were extreme obesity, abdominal scars, or if the lower fetus could not be reached transabdominally. Two hundred seventy-one women were delivered of live born babies after 24 weeks (group 1). Nineteen cases had pregnancy losses </=24 weeks (group 2). RESULTS: The complete pregnancy loss rate was 6.5% (19/290 cases). Total pregnancy loss rates of multifetal pregnancy reduction were 3.5% (7/203 reductions) for the transabdominal route and 13.3% (10/75 reductions) for the transvaginal route ( P = .004). Overall pregnancy losses were 4.8% for starting with twins, 6.6% for starting with triplets, 1.8% for starting with quadruplets, 14.3% for starting with quintuplets, and 14.3% with starting numbers of >/=6 fetuses. For finishing numbers, total pregnancy losses were 5.1% for ending with a singleton infant, 6.6% for ending with twins, and 0% for ending with triplets. Significant differences in complete pregnancy loss were observed between transabdominal and transvaginal routes for starting with triplets (2.7% for transabdominal versus 16.7% for transvaginal; P = .006) and for finishing with a single fetus (0% for transabdominal versus 20% for transvaginal; P < .004). CONCLUSION: The multifetal pregnancy reduction success rate was higher with the transabdominal route compared with the transvaginal route. Significant differences in favor of the transabdominal route were observed for starting with triplets or finishing with a single fetus. The transvaginal route should be reserved only for cases in which the transabdominal approach is hard or impossible to perform. The performance of the procedure at 12 to 13 weeks of gestation enables structural evaluation of the fetuses before reduction.

Adult↗

First-trimester maternal serum PAPP-A and free-beta subunit human chorionic gonadotropin concentrations and nuchal translucency are associated with obstetric complications: a population-based screening study (the FASTER Trial).

OBJECTIVE: The purpose of this study was to determine whether maternal serum levels of pregnancy-associated plasma protein A, free-beta subunit human chorionic gonadotropin, or nuchal translucency size are associated with obstetric complications. STUDY DESIGN: Data were obtained from the First and Second Trimester Evaluation of Risk trial. Pregnancy-associated plasma protein A and free-beta subunit human chorionic gonadotropin levels were analyzed, and nuchal translucency was measured between 10 weeks 3 days and 13 weeks 6 days of gestation in 34,271 pregnancies. RESULTS: Women with pregnancy-associated plasma protein A of < or =5th percentile were significantly more likely to experience spontaneous fetal loss at < or =24 weeks of gestation, low birth weight, preeclampsia, gestational hypertension, preterm birth ( P < .001) and stillbirth, preterm premature rupture of membranes, and placental abruption ( P < .02). Nuchal translucency at > or =99th percentile and free-beta subunit human chorionic gonadotropin at < or =1st percentile were associated with an increased risk of spontaneous loss at < or =24 weeks of gestation (adjusted odds ratios, 3.90, 3.62, respectively; P < .001). CONCLUSION: Low pregnancy-associated plasma protein A levels in the first trimester were associated strongly with a number of adverse pregnancy outcomes. Low free-beta subunit human chorionic gonadotropin levels and large nuchal translucency were both associated with early fetal loss.

Abortion, Spontaneous↗

Omphalocele-exstrophy-imperforate anus-spinal defects (OEIS) in triplet pregnancy after IVF and CVS.

BACKGROUND: Omphalocele-exstrophy-imperforate anus-spinal defects (OEIS) complex is a rare sporadic condition. CASE: We identified an infant with major malformations resembling OEIS. He was the product of a 30-week triplet pregnancy conceived by in vitro fertilization (IVF) and evaluated by chorionic villi sampling (CVS). In this article, we review the possible pathogenetic mechanisms in this case, including IVF, multiple gestation, trauma to the uterus or uterine vessels following CVS, and placenta accreta. CONCLUSIONS: We conclude that the cumulative effects of all or some of these factors may have resulted in uteroplacental insufficiency adequate to produce this phenotype. This case provides additional evidence for the uterine vascular pathogenesis of OEIS complex in humans.

Abnormalities, Multiple↗

Transvaginal ultrasound-assisted gynecologic surgery: evaluation of a new device to improve safety of intrauterine surgery.

OBJECTIVE: The purpose of this study was to evaluate a new device that couples any standard transvaginal ultrasound transducer to a special tenaculum by means of a specially designed adaptor that enables real-time ultrasound imaging and guidance of intrauterine surgical procedures. STUDY DESIGN: Forty-five patients who underwent intrauterine surgical interventions were evaluated. Forty of these patients had pregnancy terminations. Three patients had curettage for early pregnancy complications. One patient had a polyp removed, and one patient underwent hysteroscopic submucous myomectomy. Five attending physicians performed 26 procedures. Four residents in training performed 19 procedures. All operators were instructed in the assembly and use of the device before their first procedure. Evaluation of the device was done by means of a detailed questionnaire. RESULTS: The procedures were completed successfully and without complications. The time that was involved for the various components of the surgical procedures was recorded; 83% to 90% of the time the operators felt that the technique increased safety and accuracy for the parameters that were evaluated. They required fewer intrauterine instrument manipulations; in 85% of the cases, they could detect the exact end point of the procedure more accurately. In 12% of cases, the operators felt that the device interfered with the performance of the procedure. CONCLUSIONS: The transvaginal ultrasound-assisted gynecological surgery system provided high-resolution images of the cervical canal and the uterine cavity during all stages of the procedure and provided improved indication of the procedure's end point. The increased safety and accuracy that was reported by most users was encouraging. The transvaginal ultrasound-assisted gynecologic surgery system appears to provide an enhanced alternative to transabdominal ultrasound guidance for intrauterine surgical procedures.

Abortion, Induced↗

First trimester anatomy scan: pushing the limits. What can we see now?

PURPOSE OF REVIEW: The aim of this review article is to familiarize the reader with the current developments dealing with ultrasound during the first trimester of pregnancy. RECENT FINDINGS: The main emphasis of this article is to review the anatomy seen during the first trimester and to bring to the reader the fact that the first anatomical survey of the fetus does not have to wait until the 18th to 20th week of gestation. The fetus can be surveyed adequately as early as the 12th week of gestation and ideally between the 13th and 14th weeks. Of course, not all malformations will be detected during the first trimester, and a follow-up scan between 20 and 23 weeks is indicated. SUMMARY: The ongoing improvements in ultrasound technology allow us to see more details of the embryo or fetus at earlier gestational ages than ever before. This is resulting in a rethinking of when the first anatomical survey should be performed.

Female↗

Four-dimensional real-time sonographically guided cauterization of the umbilical cord in a case of twin-twin transfusion syndrome.

In the past decade, three-dimensional (3D) sonographic technology has matured from a static imaging modality to near-real-time imaging. One of the more notable improvements in this technology has been the speed with which the imaged volume is acquired and displayed. This has enabled the birth of the near-real-time or four-dimensional (4D) sonographic concept. Using the 4D feature of the current 3D sonography machines allows us to follow moving structures, such as fetal motion, in almost real time. Shortly after the emergence of 3D and 4D technology as a clinical imaging tool, its use in guiding needles into structures was explored by other investigators. We present a case in which we used the 4D feature of our sonographic equipment to follow the course and motion of an instrument inserted into the uterus to occlude the umbilical cord of a fetus in a case of twin-twin transfusion syndrome.

Adult↗

Three-dimensional ultrasound experience in obstetrics.

PURPOSE OF REVIEW: Three-dimensional (3D) ultrasound is a natural development of the imaging technology. Fast computers are essential to enable 3D and four-dimensional (4D) ultrasound pictures. A short review of the technical points and clinical aspects is presented. Our purpose is to acquaint the reader with the possibilities of this new technology and to increase awareness of its present clinical usefulness. A short review of technical information is provided. RECENT FINDINGS: The advantages of 3D and 4D ultrasound in certain areas are unequivocal. Its use in the workup of fetal anomalies involving the face, limbs, thorax, spine and the central nervous system are already applied by most centers. The use of this technology in applying color Doppler, in guiding needles for different puncture procedures as well in evaluating the fetal heart are under close research scrutiny. The bonding effect between the parents and their future offspring is becoming evident as 3D ultrasound is used. Consulting specialists understand fetal pathology better and can better plan postnatal interventions. 4D or real time 3D ultrasound was developed and is expected to achieve new meaning with the planned introduction of electronic transducer multilinear arrays. SUMMARY: 3D ultrasound is an extremely promising imaging tool to image the fetus. In spite of the scant outcome studies the potential of 3D ultrasound is understood by a large number of obstetricians, maternal fetal specialists and imaging specialists.

Biopsy, Needle↗

Sirenomelia sequence: first-trimester diagnosis with both two- and three-dimensional sonography.

OBJECTIVE: To describe the sonographic findings of sirenomelia during the first trimester on both two-dimensional sonography with color Doppler imaging and three-dimensional sonography. METHODS: Two cases of sirenomelia in primiparous patients with histories of infertility are described. The diagnosis was made on the basis of two-dimensional sonography, and three-dimensional sonography was used to further characterize the findings. RESULTS: Both fetuses had size-date discrepancies, increased nuchal translucency, large intra-abdominal vessels, and 2-vessel umbilical cords. Both pregnancies were terminated by dilation and curettage after the patients viewed the three-dimensional pictures of the fetuses. CONCLUSIONS: During the first trimester of pregnancy, rare and lethal anomalies can be diagnosed with a high degree of confidence if a thorough, age-dependent anatomic survey of the fetus is performed.

Abortion, Eugenic↗