Bilateral hemodynamic responses to auditory stimulation in newborn infants.

We studied hemodynamic auditory evoked responses of 20 healthy full-term neonates with near-infrared spectroscopy. The instrument used allows the measurements to be performed simultaneously above both auditory cortices. The stimulation consisted of 5-s trains of sound (700-ms interstimulus interval) with a 25-s silent interval. In response to the stimulation, a significant increase in concentration of oxygenated hemoglobin was detected in 14 out of 21 measurements. The mean latency of the largest response was 9.63+/-2.20 s (mean+/-SD) and the mean amplitude was 1.02+/-0.53 microM. The response amplitude was significantly larger in active (1.28+/-0.59 microM) than in quiet sleep (0.76+/-0.32 microM). The latency of the oxygenated hemoglobin concentration response was significantly shorter (r=-0.70 and p=0.0023) for infants with higher gestational age.

Acoustic Stimulation↗

Gauss-Newton method for image reconstruction in diffuse optical tomography.

We present a regularized Gauss-Newton method for solving the inverse problem of parameter reconstruction from boundary data in frequency-domain diffuse optical tomography. To avoid the explicit formation and inversion of the Hessian which is often prohibitively expensive in terms of memory resources and runtime for large-scale problems, we propose to solve the normal equation at each Newton step by means of an iterative Krylov method, which accesses the Hessian only in the form of matrix-vector products. This allows us to represent the Hessian implicitly by the Jacobian and regularization term. Further we introduce transformation strategies for data and parameter space to improve the reconstruction performance. We present simultaneous reconstructions of absorption and scattering distributions using this method for a simulated test case and experimental phantom data.

Algorithms↗

Modeling anisotropic light propagation in a realistic model of the human head.

A Monte Carlo model capable of describing photon migration in arbitrary three-dimensional geometry with spatially varying optical properties and tissue anisotropy is presented. We use the model to explore the effects of anisotropy for optical measurements of the human head. An anisotropic diffusion equation that corresponds to our Monte Carlo model is derived, and a comparison between the Monte Carlo model and the diffusion equation solution with finite elements is given.

Adult↗

Comparison between a time-domain and a frequency-domain system for optical tomography.

The quality of phase and amplitude data from two medical optical tomography systems were compared. The two systems are a 32-channel time-domain system developed at University College London (UCL) and a 16-channel frequency-domain system developed at Helsinki University of Technology (HUT). Difference data measured from an inhomogeneous and a homogeneous phantom were compared with a finite-element method (diffusion equation) and images of scattering and absorption were reconstructed based on it. The measurements were performed at measurement times between 1 and 30 s per source. The mean rms errors in the data measured by the HUT system were 3.4% for amplitude and 0.51 deg for phase, while the corresponding values for the UCL data were 6.0% and 0.46 deg, respectively. The reproducibility of the data measured with the two systems was tested with a measurement time of 5 s per source. It was 0.4% in amplitude for the HUT system and 4% for the UCL system, and 0.08 deg in phase for both systems. The image quality of the reconstructions from the data measured with the two systems were compared with several quantitative criteria. In general a higher contrast was observed in the images calculated from the HUT data.

Algorithms↗