PubMed Health⌕ Search

Biomedical subjects

Ina S Timan

Publications and source records attributed to Ina S Timan.

3 recordsLinked to original sources

Some hematological problems in Indonesia.

Indonesia consist of many island inhabited by many ethnic groups with different social economic condition. As in other parts of the world, anemia is still one of the major health problem in Indonesia. The reported anemia prevalence differs in each area and age groups, ranging from 5.4% in well nourished preschool children to 56.3% in primary school children; and 19% to 62.5% in pregnant women. The causes of anemia mostly reported were nutritional like iron deficiency, abnormal hemoglobin besides other conditions. In Cipto Mangunkusumo Hospital as the national referral hospital in Indonesia, in the adults groups, the cause of anemia reported were 14% with iron deficiency, 54% aplastic, 16% hemolytic and 16% other causes. Whereas in the child health department the cause were 29% nutritional deficiency, 31% thalassemia, 10% aplastic, 4% hemolytic and 26% other causes. Thalassemia is quite often reported in Indonesia. In 1955 Lie-Injo first reported the HbE as the most frequently found abnormality among many ethnic groups in Indonesia, ranging from 2.5% to 13.2%. In later studies the prevalence reported varies very much. It was reported as 9.5% in newborns, 22% in pregnant women, and 15.95% to 60% in athletes. The carrier frequency in some areas was between 6-10%, while the pattern of mutation varied widely within each region. Hemophilia cases in Indonesia is still not diagnosed adequately, only 530 cases were reported. The problems were lack of diagnostic laboratories and awareness. As many as 56.9% of the hemophilia patients who received cryoprecipitate were reported positive with HCV antibody. Hematological malignancy is now also became an increasing problem in Indonesia, in child health department the prevalence of leukemia was 57%, and lymphoma 13% among other malignancies. In National Cancer hospital, the prevalence leukemia as diagnosed using morphology and flowcytometry, were 51.4% AML, 19.7% B-ALL, 14.6% T-ALL, 4.5% preB-ALL, with 9.8% cases with co expression, and 30% other malignancies. Due to geographical situation, economic condition and lack of diagnostic laboratory facility many abnormalities were unable to be diagnosed properly.

Adult↗

External quality assessment scheme and laboratory accreditation in Indonesia.

The National Program on External Quality Assessment Scheme (NEQAS) in Indonesia was first started in 1979, organized by the Indonesian Ministry of Health collaborating with professional bodies. The first trial was for clinical chemistry test with 2 cycles per year, followed by the hematology NEQAS in 1986 in collaboration with WHO-Royal Post Graduate Medical School London. After that, the schemes for serology, microbiology and parasitology were also organized. Around 500-600 laboratories throughout Indonesia participated each year in these quality control schemes, 2-4 cycles per year. Samples would be sent to participants and results will be given back to each laboratory. Poor performers should participate in the workshop or training course conducted by the Central Health Laboratory to improve their results. Participation in this NEQAS is mandatory for obtaining the laboratory license, and the Ministry of Health uses these schemes as one of the means for monitoring and coordinating the performance of laboratories throughout Indonesia. There are also some other EQAS (External Quality Assessment Scheme) programs conducted by professional bodies, such as for hemostasis, clinical chemistry and serology. During the course of conducting these schemes, it could be observed that manual methods were gradually changed to the automatic methods, especially for the clinical chemistry and hematology laboratories, which counts also for improvements of their results. Since the last 6 years, the Ministry of Health also began to conduct the Accreditation System evaluation for hospitals, including the laboratory departments. There are 7 standards that were evaluated, such as the aspect of the organization, administration and management, staffing, facilities and equipment, standard operating procedures, research and developments and quality control. This accreditation program is still in progress for all public and private hospital laboratories.

Chemistry, Clinical↗

Evaluation of the stability of Cell Dyn 16 Tri Level as a control material for laboratory external quality assessment scheme on hematology.

The implementation of a laboratory test should always implement a laboratory quality control program, i.e internal quality control and external quality assessment. In an external quality assessment scheme, a control material that is stable over delivery until tested by the participating laboratory. In this study, we evaluated the stability of Cell Dyn 16 Tri Level (TL) control material at room temperature (26-32 degrees C), stored in a transport vessel containing ice pack, and the precision and accuracy of the instrument Cell Dyn 1400. The control used was Cell Dyn 16 TL with low value (L), normal value (N) and high value (H). This study was done in the Clinical Pathology Department of FKUI-RSCM during February 2001 until May 2001. Control material was stored room in a transport vessel containing ice pack for 15 days, then analysed macroscopically, microscopically and evaluated for its stability. Test for precision and accuracy was done within run and for precision between day on Cell Dyn 1400. The result of this study showed a macroscopic change beginning on day 14 (L) day 12 (N) and day 15 (H). Microscopic change was observed on day 13 (L and N) and day 15 (H), Erythrocyte and hemoglobin level was stable until day 15. Changes in leukocyte was seen on day 14 (L), day 12 (N) and day 15 (H). Platelet showed instability on day 9 (L), day 10 (N and H). Mean erythrocyte volume was out of range on day 15 (L), but the N and H control was still stable. The precision and accuracy of Cell Dyn 1400 was in WHO recommended range. We concluded that the precision and accuracy of Cell Dyn 1400 is good. Cell Dyn 16 TL control material was stable until day 9, and its can be recommended to be used as a control material for external quality assessment scheme.

Blood Cell Count↗