PubMed Health⌕ Search

Biomedical subjects

Inderjit S Gill

Publications and source records attributed to Inderjit S Gill.

15 recordsLinked to original sources

Nonoperative management of traumatic aortic injury.

BACKGROUND: The standard management for patients with blunt aortic injury is surgery; however, a small number of patients have been medically managed. The outcome of these nonoperatively managed patients is unknown. METHODS: Seven patients diagnosed as blunt aortic injury were managed without aortic surgery between January 1993 and April 2002, and their outcomes were retrospectively investigated. RESULTS: There were three men and four women, with a mean age of 48.7+/-22.7 years and Injury Severity Score of 37.7+/-16.9. The reason for nonoperative management was refusal of surgery (2), do-not-resuscitate order (1), diffuse brain injury (2), small intimal tear (1), and technical difficulty (1). Two patients died resulting from associated injuries. Five patients are alive, and in three patients complete resolution of aortic injury was observed. CONCLUSIONS: In selected patients with multiple associated injuries or severe comorbidity, nonoperative management after blunt aortic injury can be a treatment of choice.

Adult↗

Internal thoracic artery to left anterior descending anastomosis performed on the beating heart by endoscopic robot assistance using a new distal connector.

BACKGROUND: Automated distal connecting devices have been recently introduced to facilitate coronary anastomosis. This could have a large impact on the capacity of robotic systems to perform completely endoscopic off-pump bypass, where the quality of anastomosis and the prolonged operative time for the performance of the anastomosis have until now been cause for concern. Our group tried to determine the feasibility and efficacy of the JoMed distal graft connector using the ZEUS robotic system. METHODS: Six swine, with a mean weight of 25.8 (standard deviation [SD] 2.2) kg, underwent endoscopic off-pump internal thoracic artery-left anterior descending (ITA-LAD) anastomosis with a special stabilizing system using ZEUS robotic assistance. The anastomosis was performed with the JoMed distal connector. RESULTS: The connector was employed successfully in 4 of 6 cases using a special delivery instrument. Two animals fibrillated within 2 minutes after the application of proximal occluding snares and were excluded from the analysis. The total device deployment time was 2 minutes 4 seconds (SD 50 s) in 4 of 6 survivors, which remained hemodynamically stable and in sinus rhythm until euthanasia. Coronary angiography and transonic flow measurements were used to verify patency. CONCLUSION: The JoMed distal graft connector may facilitate the use of robot-assisted endoscopic bypass on a beating heart. Long-term patency issues will need to be assessed.

Animals↗

Intraoperative glucose control in diabetic and nondiabetic patients during cardiac surgery.

OBJECTIVE: The purpose of this study was to evaluate intraoperative glucose control. DESIGN: Prospective unblinded study. SETTING: Tertiary care center. PARTICIPANTS: Diabetic (n = 17) and nondiabetic (n = 23) patients undergoing elective cardiac surgery. INTERVENTIONS: Diabetics received a modified insulin regimen consisting of a fixed rate infusion of regular insulin, 10 U/m2/h, and a variable infusion of D10W, adjusted to maintain glucose between 101 to 140 mg/dL. MEASUREMENTS AND MAIN RESULTS: Baseline glucose was higher in diabetics versus nondiabetics (mean +/- standard error of the mean: 203 +/- 27 v 117 +/- 3 mg/dL, p < 0.005). After baseline, insulin levels were increased in diabetics to 410 to 568 microU/mL. Corresponding insulin levels in nondiabetics were 12 to 40 microU/mL. Compared with baseline, glucose was decreased by 10% +/- 29% in diabetics during hypothermic cardiopulmonary bypass and increased by 21% +/- 30% in nondiabetics (p < 0.005). After discontinuation of bypass, glucose was lower in diabetics (137 +/- 12 mg/dL) versus nondiabetics (162 +/- 8 mg/dL, p < 0.005). Nine diabetics had adequate intraoperative glycemic control during hypothermic bypass (glucose 123 +/- 8 mg/dL, insulin 550 +/- 68 microU/mL, glucose infusion rate 1.87 +/- 0.29 mg/kg/min), 6 approached adequate control near the end of surgery (glucose 147 +/- 8 mg/dL, insulin 483 +/- 86 microU/mL, glucose infusion rate 0.35 +/- 0.05 mg/kg/min), and 2 never achieved control. Diabetics with elevated initial glucose >300 mg/dL did not achieve adequate glycemic control. Four diabetics (3 with renal failure) required injection of 50% dextrose after bypass for hypoglycemia. CONCLUSION: Adequate glycemic control can be achieved in most diabetics during cardiac surgery using a modified insulin clamp technique provided initial glucose is <300 mg/dL.

Aged↗

Redo-aortic valve replacement after previous bilateral internal thoracic artery bypass grafting.

BACKGROUND: Aortic valve replacement (AVR) after coronary artery bypass using bilateral internal thoracic arteries (ITAs) is a challenge. Management of these patent grafts and myocardial protection are important issues. Moreover the risk and outcome of these complex operations have not been clearly defined. METHODS: Eighteen consecutive patients (all male) who exhibited previous bilateral ITA grafts underwent subsequent AVR surgery from 1990-2001 at the Cleveland Clinic Foundation. Their medical records were retrospectively analyzed. RESULTS: At the time of reoperation, the mean age of the patients was 67 +/- 6.4 years and 33 out of 36 (92%) ITAs were patent. The interval between previous coronary bypass and aortic valve surgery was 10.3 +/- 5.3 years. All patients underwent redo-median sternotomy with aortic cannulation in 12 patients (67%) and femoral or axillary artery cannulation in 6 patients (33%). The patent ITAs were clamped during aortic cross-clamping in 15 patients. In 3 patients the ITAs were not dissected. These 3 patients underwent deep hypothermic arrest for myocardial protection. Concomitant coronary revascularization was performed in 8 patients (44%). There were no hospital deaths. One stroke occurred but there were no other major complications. Average intubation time was 23.1 +/- 27.1 hours, intensive care unit stay was 2.3 +/- 3.1 days, and postoperative hospital stay was 10.3 +/- 7.6 days. CONCLUSIONS: Reoperative aortic valve surgery in the patients with patent bilateral ITA grafts can be performed safely.

Aged↗

Migration of an inferior vena cava filter to the right ventricle and literature review.

Migration of an inferior vena cava (IVC) filter to the heart after placement is an extremely rare complication. The case of a 42-year-old man who presented with ventricular arrhythmia and tricuspid valve regurgitation, and underwent open heart surgery to extract an IVC filter from the right ventricle 12 days after infrarenal IVC filter placement, is reported.

Adult↗

Robotically assisted endoscopic transmyocardial laser revascularization.

BACKGROUND: The surgical approach to transmyocardial laser revascularization (TMR) via thoracotomy has been approved for the treatment of angina in inoperable patients, but it has had limited use as a stand-alone procedure. OBJECTIVES: To assess the feasibility and efficacy of robotically assisted endoscopic TMR using the Zeus robotic surgical system (Computer Motion, USA) and an excimer TMR system (Spectranetics, USA) in a porcine model. METHODS: Five pigs weighing 20 kg to 40 kg were used. A 10 mm endoscope, two 5 mm instrument ports and a 1.4 mm TMR probe were introduced into the left hemithorax. Endoscopic TMR was performed on the anterolateral or lateral left ventricular wall using Zeus instruments to hold and guide the TMR probe. RESULTS: The mean system set-up time was 4.2+/-0.6 min, the mean port placement time was 11+/-1.7 min, the mean TMR procedure time was 5.0+/-0.7 min and the mean number of transmural TMR channels was 10+/-3.6. All pigs tolerated the entire procedure. Histological examination showed that transmural channels were successfully created. CONCLUSIONS: Endoscopic TMR using the Zeus system was feasible, in a pig model, in creating transmural laser channels on the anterior and lateral left ventricle, and may provide a significant advantage over the open chest approach in reducing perioperative morbidity and improving recovery.

Animals↗

Blunt injury of the innominate artery: a case report and review of literature.

Innominate artery injury after blunt trauma is uncommon and mostly observed at its origin from the aorta. We report here an unusual case of distal innominate artery injury associated with acute right subclavian occlusion. MEDLINE search of blunt traumatic injury to the innominate artery revealed a total of 132 case reports by the end of 2003, including this case report, and all these published studies were reviewed.

Brachiocephalic Trunk↗

Delayed operative intervention in the management of traumatic descending thoracic aortic rupture.

BACKGROUND: Outcomes may be improved by purposefully delaying surgical intervention of the traumatically ruptured descending thoracic aorta. METHODS: Fifty-seven patient records identified through the Trauma Registry of a level 1 trauma center between January 1993 and April 2002 were retrospectively analyzed between groups who underwent "clamp-and-sew" versus partial left heart bypass repair techniques and between emergent versus delayed repair. RESULTS: Thirty-two (56%) of 57 patients were male. The mean age among survivors and nonsurvivors was 41 +/- 18 (range 13 to 70) and 52 +/- 23 (range 18 to 92; p = 0.04) years, and Injury Severity Score was 31 +/- 13 (range 17 to 75) and 40 +/- 16 (range 16 to 75; p = 0.04) points, respectively. Thirty-one (54%) underwent surgical intervention, 20 (35%) died during their initial resuscitation, and 6 (11%) were managed nonoperatively. Seventeen (55%) were repaired using partial left heart bypass and 14 (45%) using the clamp technique. Twenty-one (68%) had emergent repair and 10 (32%) had delayed repair. The rates of paraplegia, renal failure, and mortality were 12% (2 of 17), 0%, and 24% (4 of 17) in the bypass group, 0% (p = 0.29), 0%, and 36% (5 of 14, p = 0.36) in the clamp group, 9.5% (2 of 21), 0%, and 38% (8 of 21) in the emergent group (<24 hours after admission), and 0% (p = 0.45), 0%, and 10% (1 of 10, p = 0.12) in the delayed group (>24 hours after admission), respectively. Mean clamp times for the bypass and clamp groups were 44 +/- 18 (21 to 90) and 30 +/- 10 (14 to 52) minutes, respectively (p = 0.02). Overall operative mortality was 29% (9 of 31). CONCLUSIONS: Purposefully delaying surgical intervention in selected cases of descending thoracic aortic rupture and using the clamp technique does not increase mortality or morbidity over immediate operation and use of partial left hear bypass.

Adolescent↗

Biventricular pacing for congestive heart failure: early experience in surgical epicardial versus coronary sinus lead placement.

OBJECTIVE: Biventricular pacing (BVP) has recently been introduced for the treatment of refractory congestive heart failure. Coronary sinus lead placement for left ventricular pacing is technically difficult, has a risk of lead dislodgement, and has long procedure times. Surgical epicardial lead placement has the potential advantage of the visual selection of an optimal pacing site, does not need exposure to ionic radiation, and allows lead multiplicity, but it does require a thoracotomy and general anesthesia. We report our early experience of BVP with both modalities. METHODS: BVP was performed in 12 patients with New York Heart Association (NYHA) class IV congestive heart failure (10 men, 2 women). Mean patient age was 68.7 years (range, 41-83 years). Surgical epicardial leads were placed through a 2- to 3-inch incision via a left fourth or fifth intercostal thoracotomy in 4 patients with single lung ventilation under general anesthesia. The other 8 patients underwent transvenous coronary sinus lead placement under conscious sedation. RESULTS: Postoperative NYHA class status improved from class IV to class II in 8 patients and to class III in 3 patients. In 5 of the 8 patients who had undergone follow-up echocardiography with mitral regurgitation, the severity of the mitral regurgitation improved. The mean left ventricular ejection fractions before and after BVP were 18.3% +/- 8.3% and 20.5% +/- 8.0%, respectively (P =.16). Mean fluoroscopy and total procedure times for transvenous lead placement were 77 +/- 19 minutes and 266 +/- 117 minutes, respectively. The mean surgery time for epicardial lead placement was 122 +/- 13 minutes. There were no differences between the 2 methods in pacing threshold or in lead dislodgement. There were no complications related to the surgery or the laboratory procedure. CONCLUSION: In patients with NYHA class IV congestive heart failure, epicardial lead placement through a minithoracotomy for BVP was performed safely with benefits equivalent to those of coronary sinus lead placement and with a shorter procedure time.

Adult↗