PubMed Health⌕ Search

Biomedical subjects

Inger Wendelhag

Publications and source records attributed to Inger Wendelhag.

9 recordsLinked to original sources

A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

BACKGROUND: Based on three-dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively. PURPOSE: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study. MATERIALS AND METHODS: Twenty-seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth-in-an-Hour concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan-derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure. RESULTS: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable. CONCLUSION: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three-dimensional oral implant planning software, of both surgical templates for flapless surgery and dental prostheses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.

Adult↗

Immediate/early function of Brånemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study.

BACKGROUND: The advantages of placing implants in fresh extraction sockets and putting them in immediate/early function are many. A predicable protocol opens the possibility of performing a single surgical procedure, giving the patient a temporary prosthesis immediately, and minimizing the shrinkage of hard tissue and soft tissue recession. PURPOSE: The aim of the present study was to develop a strict protocol for and to evaluate the feasibility of immediate/ early function on implants placed in fresh extraction sockets located in maxillae and posterior mandibles, including defects around the implants treated according to a regenerative procedure. MATERIALS AND METHODS: Nineteen patients were treated after tooth extraction according to an immediate function protocol and were observed for 18 months. Fifty Mk IV TiUnite (Nobel Biocare AB, Göteborg, Sweden) implants were installed in partially edentulous areas in maxillae (n = 17) and posterior mandibles (n = 5). Implants were installed directly into the alveoli, and the temporary prostheses were connected immediately after surgery (n = 11) or within 7 days, that is, an "early function" procedure (n = 11). Thirteen implants did not require any type of regenerative procedure, whereas the remaining 37 implants had filling with autogenous bone, 4 of which also had a resorbable membrane. Standardized intraoral radiographs were taken for evaluation of marginal bone level, and 38 of the implants were systematically checked by resonance frequency analysis. RESULTS: All patients were followed for 18 months, and none of the 50 implants failed. However, one implant showed signs of failure after 6 weeks, but once the occlusal load was removed, the implant regained its stability completely, no longer demonstrated symptoms, and could be used successfully for prosthetic rehabilitation. The mean value of the implant stability quotient was 60 at baseline (range 45-75) and 63 after 6 months (range 46-75). The marginal bone resorption was 0.9 mm (SD 1.1 mm; n = 48) 18 months after implant insertion (1 year after final prosthesis). CONCLUSION: The immediate placement of implants into fresh extraction sockets combined with immediate/early function procedures seems to be a safe and reliable procedure when using a strict protocol.

Adult↗

Early function of splinted implants in maxillas and posterior mandibles, using Brånemark System Tiunite implants: an 18-month prospective clinical multicenter study.

BACKGROUND: Immediate or early loading of implants placed in maxillas and posterior mandibles has been a concern as bone density is often low in these areas, making it difficult to establish good initial implant stability. By adapting implant design and insertion protocols, however, high initial implant stability may be achieved in these regions. Further, a modified implant surface texture has been proved to help in maintaining stability during the initial healing period. PURPOSE: The aim of the present study was to investigate the clinical performance of oxidized titanium implants (TiUnite, Nobel Biocare AB, Gothenburg, Sweden) when used for early function in the maxilla and in the posterior mandible, locations where the bone density often is low. A further aim was to evaluate the marginal bone level at oxidized implants and compare it with that of machined-surface implants used in a previous study. MATERIALS AND METHODS: Thirty-one patients were consecutively included in the study, and 37 edentulous areas in maxillas and posterior mandibles were treated. Bruxism and uncontrolled periodontal disease were exclusion criteria. Temporary prostheses were generally placed within 9 days but not after 16 days from implant placement. A previous study applying the same study design and clinical protocol but using machined-surface implants was used for comparisons. RESULTS: Of the 111 implants installed, 1 failed, giving an overall survival rate of 99.1% after 18 months. The prosthesis survival was 100%. The marginal bone resorption was 0.8 mm (standard deviation [SD], 1.0), as opposed to 1.6 mm (SD, 1.3) in the previous study with machined-surface implants, but was not statistically significantly different (p = .10). CONCLUSION: The present clinical protocol (aiming at high primary stability) and the use of oxidized titanium implants for early functional loading in the maxilla and the posterior mandible resulted in a high implant survival rate and a favorable marginal bone level during a follow-up of 18 months. The difference in marginal bone resorption between the oxidized implants in the present study and the machined implants from a previous investigation with the same study design was not statistically significant.

Adult↗

3-year prospective multicenter study on one-stage implant surgery and early loading in the edentulous mandible.

BACKGROUND: The long-term success rates achieved in dental implantology suggest that flexibility might well exist within the various implant systems to a degree that an altered protocol (ie, one-stage surgery and immediate or early loading) can be performed under controlled conditions. However, before variations of the protocol can be considered for general use, they must be subjected to critical analysis, particularly with respect to the predictability of osseointegration, alteration of soft tissue barrier, and relative change in bone height around the implants. PURPOSE: The aim of this prospective multicenter study was to evaluate implant survival and periimplant conditions around endosseous implants placed in a one-stage surgical procedure and early loading. MATERIALS AND METHODS: A total of 170 implants were placed in 40 patients with mandibular edentulism and were functionally loaded within 6 weeks with overdentures (n = 30) or fixed prostheses (n = 10). All patients and prosthetic constructions were evaluated according to a standardized protocol during 3 years of follow-up. Cumulative implant survival rates were calculated, and implant loss in relation to implant size and bone quality and quantity were evaluated. Furthermore, the protocol included assessment of clinical (plaque and bleeding scores, prosthesis stability) and radiographic parameters. RESULTS: Over a period of 3 years, the implant survival rate was 93% for both implants and prostheses (fixed or removable). No implants were lost after the first year of loading. The periimplant tissues were in a healthy condition. Mean marginal bone resorption from the time of loading to the 3-year follow-up was 0.41 mm (SD 0.52). CONCLUSIONS: From this study it may be concluded that early loading results in good implant survival and proper periimplant health in edentulous mandibles.

Adult↗

Prospective multicenter study on immediate rehabilitation of edentulous lower jaws according to the Brånemark Novum protocol.

BACKGROUND: During recent years a new treatment concept, Brånemark Novum, has been developed in which implants are inserted in the edentulous lower jaw and immediately connected to a prefabricated titanium bar. A fixed prosthesis is then attached to the bar during or immediately following surgery. PURPOSE: The aim of the present study was to investigate the application of this concept under various settings, to determine technique sensitivity, and to evaluate the clinical outcome after 1 year of follow-up. MATERIALS AND METHODS: Fifty-one patients were included in a prospective multicenter investigation and followed up for 1 year. Cumulative implant survival rates were evaluated by life table analysis. In addition, clinical comparisons were performed to evaluate implant loss in relation to patient characteristics. Questionnaires were used to evaluate the treatment protocols and to obtain patients' opinions. RESULTS: The prosthetic treatment was completed on the same or the following day in 76% of the patients. The cumulative implant survival rates for implants and prostheses were 91% and 94%, respectively, after 12 months. CONCLUSIONS: The present study demonstrated that single-stage surgery and immediate loading of implants with prefabricated bridgework in the mandible can result in high implant success and significant reduction in treatment time, with patient satisfaction.

Adult↗

Intima-media thickness in cardiovascularly asymptomatic hypopituitary adults with growth hormone deficiency: relation to body mass index, gender, and other cardiovascular risk factors.

OBJECTIVE: Increased cardiovascular mortality and carotid atherosclerosis have been observed in hypopituitary patients with untreated GH deficiency (GHD), but results are contradictory and relations to cardiovascular risk factors are not clear. The aim of this study was to investigate intima-media thickness (IMT) in relation to cardiovascular risk factors in adults with GHD. DESIGN: Cross-sectional observational study of 21 men and 13 women with GHD, but without cardiovascular disease, compared to two healthy control groups matched for age, sex and smoking habits. One control group was matched for body mass index (BMI) and the other group was nonobese. MEASUREMENTS: IMT of the carotid and femoral arteries, blood pressure, blood samples and anthropometric data. RESULTS: Patients had 12% thicker composite carotid IMT [(IMT of common carotid artery + IMT of bulb)/2] compared to nonobese controls (P = 0.022), but IMT was not different compared to BMI-matched controls. Femoral IMT did not differ between patients and controls. Patients had higher waist : hip ratio (WHR), heart rate, serum triglycerides and fasting insulin concentrations in combination with lower high-density lipoprotein (HDL) cholesterol and smaller low-density lipoprotein (LDL) peak particle size compared to both nonobese and to BMI-matched controls. This cardiovascular risk pattern was more pronounced in female patients than in male patients compared to their gender controls. Carotid IMT was related to age, serum cholesterol, LDL cholesterol and smoking in the patient group. Only age was independently related to carotid IMT in multivariate analysis. CONCLUSIONS: These results indicate that high BMI in GH-deficient patients contribute to their increased intima-media thickness. However, several cardiovascular risk factors are present in this patient group independent of their increased BMI, especially in women.

Adult↗

Implant-supported welded titanium frameworks in the edentulous maxilla: a 5-year prospective multicenter study.

PURPOSE: This study evaluated the 5-year clinical and radiographic performance of fixed implant-supported maxillary prostheses with either welded titanium or conventional cast-gold alloy frameworks. MATERIALS AND METHODS: Fifty-eight consecutive patients were provided with 349 osseointegrated Brånemark system implants in the edentulous maxilla at six different implant centers. Twenty-eight of the patients received, at random, prostheses with laser-welded titanium frameworks, and the remaining 30 patients had prostheses with conventional cast-gold alloy frameworks. Clinical and radiographic data were collected for 5 years after prosthesis placement. RESULTS: The titanium and cast-gold framework groups exhibited similar cumulative survival and success rates (CSR). The 5-year implant CSR from time of placement was 91.4% and 94.0%, respectively, and from prosthesis delivery the rate was 94.9% and 95.6%, respectively. The corresponding 5-year prosthesis CSRs were 96.4% and 93.3%. One patient from each group lost all the implants and turned to complete dentures within the first year of function. Another patient with a cast-gold framework had the prosthesis replaced after 4 years, basically because of problems with the veneering material. No fractures of implant components were observed during the follow-up period. Bone loss was on average 0.59 mm (SD 0.97 mm) during 5 years, with no statistical difference between the two groups. CONCLUSION: Welded titanium frameworks presented a similar favorable clinical performance as conventional cast-gold alloy frameworks in fixed implant-supported prostheses in the edentulous maxilla after 5 years in function. Implant failures were concentrated in only a few patients in each study group.

Adult↗

Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study.

PURPOSE: This study evaluated and compared the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with that of conventional cast frameworks in the partially edentulous jaw. MATERIALS AND METHODS: Forty-two patients provided with Brånemark system implants were arranged into two groups. Twenty-one patients (group A) were provided with a conventional cast ceramometal framework in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain in the other side. In group B, 21 patients received a titanium framework prosthesis to replace a conventional implant prosthesis. Clinical and radiographic data were collected for 5 years. RESULTS: Four implants and one titanium framework were lost during the follow-up period. The two framework designs did not show any significant differences with regard to implant or prosthesis survival (P > .05). Few clinical complications were observed. In group A, marginal bone loss after 5 years was similar for both prosthesis designs, with an average of 0.1 mm and 0.3 mm in the maxilla and mandible, respectively. Basically, no bone loss was observed on average in group B. Furthermore, no significant relationship was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. CONCLUSION: Except for an insignificant tendency toward a slightly higher incidence of small chips of porcelain veneers, laser-welded titanium frameworks presented an overall similar clinical performance as conventional cast frameworks in partial implant situations after 5 years.

Adult↗

Resonance frequency analysis measurements of implants at placement surgery.

PURPOSE: The knowledge of what levels of primary stability can be obtained in different jawbone regions and of what factors influence primary stability is limited. The objective of this study was to evaluate primary stability by resonance frequency analysis (RFA) measurements of implants placed according to a surgical protocol that aimed for high primary stability. The aim was also to correlate RFA measurements with factors related to the surgical technique, the patient, and implant design. MATERIALS AND METHODS: A total of 905 Brånemark dental implants used in 267 consecutive patients were measured with RFA at the time of placement surgery. RESULTS: A mean ISQ value of 67.4 (SD 8.6) was obtained for all implants. Univariate analyses with the implant or patient as unit showed higher ISQ values in men compared with women, in mandibles compared with maxillae, in posterior compared with anterior sites, and for wide-platform implants in comparison with regular/narrow-platform implants. There was a correlation between bone quality and primary stability, with lower ISQ values obtained for implants placed in softer bone. A lower stability was seen with increased implant length. A stepwise multiple regression analysis using the patient as unit showed that jaw type and gender had independent effects on primary stability. CONCLUSION: The results suggest that factors related to bone density and implant diameter/length may affect the level of primary implant stability. Furthermore, greater stability was observed in male than in female patients. High primary implant stability was achieved in all jaw regions, although the use of thinner drills and/or tapered implants cannot fully compensate for the effect of soft bone. The research design does not permit conclusions regarding long-term treatment outcome with implants.

Aged↗