PubMed Health⌕ Search

Biomedical subjects

Ioannis Ignatiadis

Publications and source records attributed to Ioannis Ignatiadis.

2 recordsLinked to original sources

Cr(VI) quantification using an amperometric enzyme-based sensor: interference and physical and chemical factors controlling the biosensor response in ground waters.

The development of an amperometric enzyme-based sensor for chromate (CrO(4)(2-)) quantification in ground waters was investigated. Crucial physical and chemical factors characterising ground waters were tested for their influence or interference on chromate quantification: pH (7.6-8.5), temperature (9-25 degrees C), ionic strength (0-0.2M), oxygen, metals, bicarbonate and sulphate. The biosensor's response was dependent on temperature and pH as sensitivity increased with temperature and was higher at pH 7.6 than at pH 8.5. Sensitivity decreased with ionic strength until 0.1M, and was stable for higher values. Dissolved oxygen did not allow chromate quantification when it was present, but O(2) could be eliminated by adding Na(2)SO(3) or bubbling nitrogen gas into the solution. Bicarbonate did not interfere with chromate quantification by the biosensor. Sulphate was detected with a detection threshold 80 times higher than that of chromate and a lower sensitivity. Several metals (V(V), W(VI), Mn(VII), Mo(VI)) similar to chromate due to their oxidative properties and structure (oxyanions) were tested as possible interfering compounds. The sensitivity of the biosensor for these metals was low and the detection level was 30 times higher than that of chromate. These metal concentrations are usually weaker than chromate concentration in polluted ground waters so that dilution of the sample should allow chromate quantification by the biosensor. This study shows that the cytochrome c(3)-based sensor can detect compounds other than chromate but with a lower sensitivity. Although non-specific for the detection of chromate, it can however be adapted and used for the quantification of chromate in ground waters containing low sulphate concentration.

Anions↗

Amperometric cytochrome c3-based biosensor for chromate determination.

The chromate reductase activity of cytochrome c(3) (Cyt c(3), M(r) 13000), isolated from the sulfate-reducing bacterium Desulfomicrobium norvegicum, was used to develop an amperometric biosensor to measure chromate (CrO(4)(2-)) bioavailability. The performance of various biosensor configurations for qualitative and quantitative determination of Cr(VI) was studied. Biosensor properties depend on the technique used to immobilize the enzyme on the electrode (glassy carbon electrode). Immobilization of Cyt c(3) by entrapment in poly 3,4-ethylenedioxythiophene films denatured the enzyme, while application of an adsorption technique did not affect enzyme activity but the detection range was limited. The best results were obtained with dialysis membranes, which allowed the determination of Cr(VI) from 0.20 to 6.84 mg l(-1) (3.85-132 microM) with a sensitivity of 35 nA mg(-1) l (1.82 nA microM(-1)). No interference was observed with As(V), As(III) and Fe(III). Only a small amount of Cyt c(3) (372 ng of protein) was needed for this biosensor.

Biosensing Techniques↗