PubMed Health⌕ Search

Biomedical subjects

Irena Vovk

Publications and source records attributed to Irena Vovk.

2 recordsLinked to original sources

Rotation planar extraction and rotation planar chromatography of oak (Quercus robur L.) bark.

The versatile novel instrument for rotation planar extraction and rotation planar chromatography was exploited for the investigation of oak bark (Quercus robur L.). The same instrument enabled extraction of the bark, analytical proof of (+)-catechin directly in the crude extract and also its fractionation. Additionally, epimeric flavan-3-ols, (+)-catechin and (-)-epicatechin were separated by analytical ultra-micro rotation planar chromatography on cellulose plates with pure water as developing solvent. A comparison of the extraction of oak bark with 80% aqueous methanol by rotation planar extraction and medium pressure solid-liquid extraction was carried out and both techniques were shown to be suitable for the efficient extraction of oak bark. The raw extracts and fractions on thin-layer chromatography showed many compounds that possessed antioxidant activity after spraying with 1,1-diphenyl-2-picrylhydrazyl. Rotation planar fractionation of 840 mg of crude oak bark extract on silica gel gave 6.7 mg of pure (+)-catechin in one run.

Chromatography, Liquid↗

Uncertainty in quantitative thin-layer chromatography.

Globalization forces analysts to demand extended control of variability in analytical measurements. A calculation procedure named the "error budget model" following recommendations proposed more than 20 years ago by the Bureau International des Poids et Mesures is established as a rule for evaluating and expressing the measurement uncertainty across a broad spectrum of measurements. This metrological approach common in physical measurement is not applicable in separation techniques and cannot quantitate measurement uncertainty. Our experiments show that it can be used as a planning tool in the validation of thin-layer chromatographic (TLC) methods. A computer program that quantitates uncertainty components associated with potential sources of uncertainty in quantitative TLC is prepared and tested with experimental data. TLC plates with different qualities of stationary phases (TLC and high-performance TLC) spotted with different types of samples are measured. Application is performed manually and automatically. Plates are scanned with UV-vis scanners and a video documentation system in remission and transmission mode and fluorescence. Although the calculated values are close to the values obtained with validation procedures, the error budget approach cannot substitute validation. Calculated results can predict critical points in real quantitative TLC, but they cannot confirm the validity of a selected chromatographic procedure.

Journal Article↗