PubMed Health⌕ Search

Biomedical subjects

Irene M Vavasour

Publications and source records attributed to Irene M Vavasour.

3 recordsLinked to original sources

Reproducibility and reliability of MR measurements in white matter: clinical implications.

The purpose of this study was to determine the reproducibility and reliability of five MRI-derived measurements, namely, total water content (WC), myelin water content (MWC), mean T2 relaxation time (GMT2), T1 relaxation time (T1) and magnetization transfer ratio (MTR). Five controls were scanned 5 times over 1 year. The five MR measurements were made for 5 white matter regions. All measurements were found to be highly reproducible. MTR had a low reliability coefficient because all individual values were similar. Therefore, MTR would be most sensitive in detecting changes from normal. WC had a high reliability coefficient in all regions. For MWC, GMT2 and T1, the overall reliability coefficients were high but for some individual regions were low. The high coefficients suggest that these measurements, although different between normal subjects, are consistent over time. They could be used to explore natural differences in the normal population, but due to the large spread in normal values, larger sample sizes are needed to detect pathological changes.

Adult↗

Evolution of focal and diffuse magnetisation transfer abnormalities in multiple sclerosis.

Magnetisation transfer (MT) imaging provides indirect information on tissue structure abnormalities in areas that otherwise may appear normal on conventional MRI. We determined the evolution of MT changes in normal appearing white matter (NAWM) and lesion on serial examination of 9 multiple sclerosis (MS) patients and age matched controls. The mean NAWM MT ratio (MTR) was found to correlate strongly (R = 0.93) with the length of time since the patient's first clinical presentation and was well characterized by a linear decrease of -0.16%/year (p < 0.0001). The time zero intercept of the NAWM MTR regression was 30.7 +/- 0.2%, not different from the average MTR of white matter from controls (30.4 +/- 0.2 %). An additional gradual decrease in NAWM MTR was observed 6 to 12 months before the appearance of a new lesion on conventional MRI, while a more precipitous decrease in MTR was seen 2 to 6 months before the lesion appeared. Those lesions that exhibited pre-lesion MTR decreases showed less MTR recovery than lesions which had no pre-lesion MTR decrease. The data suggest that the MTR of NAWM in MS undergoes a slow progressive decrease that starts at disease onset and accelerates rapidly in focal areas just prior to lesion appearance on conventional MRI.

Adult↗

Normal-appearing white matter in multiple sclerosis has heterogeneous, diffusely prolonged T(2).

T(2) relaxation in normal-appearing white matter (NAWM) of multiple sclerosis (MS) patients was reexamined using more complete sampling and analysis of decay curves, and to assess focal vs. diffuse abnormalities. Nine MS patients and 10 controls were scanned using a single-slice 32-echo pulse sequence with a 10-ms echo spacing. Decay curves from outlined white and gray matter structures were analyzed using non-negative least-squares (NNLS). Resulting T(2) distributions were each summarized by the geometric mean T(2), T(2). Different white matter structures had different mean (over the subjects in a group) T(2). Mean T(2) in NAWM was always greater than that of controls. Differences were not caused by a few voxels with extreme T(2) (i.e., focal lesions), but rather by shifts of the entire T(2) distribution (diffuse prolongation). This T(2) increase suggests diffuse myelin or axonal pathology.

Adult↗