PubMed Health⌕ Search

Biomedical subjects

Irving Sivin

Publications and source records attributed to Irving Sivin.

13 recordsLinked to original sources

Local and systemic effects of intranodally injected CpG-C immunostimulatory-oligodeoxyribonucleotides in macaques.

Immunostimulatory CpG-C oligodeoxyribonucleotides (ISS-ODNs) represent a promising strategy to enhance vaccine efficacy. We have shown that the CpG-C ISS-ODN C274 stimulates macaque blood dendritic cells (DCs) and B cells and augments SIV-specific IFN-gamma responses in vitro. To further explore the potential of C274 for future vaccine studies, we assessed the in vivo effects of locally administered C274 (in naive and healthy infected macaques). Costimulatory molecules were marginally increased on DCs and B cells within cells isolated from C274-injected lymph nodes (LNs). However, cells from C274-injected LNs exhibited heightened responsiveness to in vitro culture. This was particularly apparent at the level of CD80 (less so CD86) expression by CD123(+) plasmacytoid DCs and was further boosted in the presence of additional C274 in vitro. Notably, cells from C274-injected LNs secreted significantly elevated levels of several cytokines and chemokines upon in vitro culture. This was more pronounced when cells were exposed to additional stimuli in vitro, producing IFN-alpha, IL-3, IL-6, IL-12, TNF-alpha, CCL2, CCL3, CCL5, and CXCL8. Following C274 administration in the absence of additional SIV Ag, endogenous IFN-gamma secretion was elevated in LN cells of infected animals, but SIV-specific responses were unchanged. Endogenous and SIV-specific responses decreased in blood, before the SIV-specific responses rebounded by 2 wk after C274 treatment. Elevated IFN-alpha, CCL2, and CCL5 were also detected in the plasma after C274 injection. Thus, locally administered C274 has local and systemic activities, supporting the potential for CpG-C ISS-ODNs to boost immune function to enhance anti-HIV vaccine immunogenicity.

Animals↗

Comparative effects of a contraceptive vaginal ring delivering a nonandrogenic progestin and continuous ethinyl estradiol and a combined oral contraceptive containing levonorgestrel on hemostasis variables.

OBJECTIVE: This study aimed to compare the effects on hemostasis variables of a contraceptive vaginal ring with those of an oral contraceptive. STUDY DESIGN: Twenty-three and 22 healthy premenopausal women were randomized to the contraceptive vaginal ring (150 microg Nestorone and 15 microg ethinyl estradiol) or Stediril 30 during 3 cycles. Analysis of covariance was performed with baseline values as covariate. RESULTS: The contraceptive vaginal ring changed most hemostasis variables similarly but raised (95% confidence intervals of percent treatment differences) Factor VIIt (28% to 49%), extrinsic activated protein C resistance (14% to 65%), and sex hormone-binding globulin (117% to 210%) and lowered Protein S (-32% to -16%) and the global activated partial thromboplastin time-based activated protein C resistance (-12% to -2%) more than the oral contraceptive. CONCLUSION: The contraceptive vaginal ring affected some measured hemostasis variables and sex hormone-binding globulin differently from the oral contraceptive, most likely because of difference in androgenicity of the progestins. The results suggest that the contraindications for oral contraceptive use would also apply to the tested contraceptive vaginal ring.

Activated Protein C Resistance↗

Contraceptive vaginal rings releasing Nestorone and ethinylestradiol: a 1-year dose-finding trial.

In a multicenter 1-year trial of contraceptive vaginal rings (rings) involving 150 women, three dose combinations of the progestin Nestorone (NES) and ethinylestradiol (EE) were compared with respect to effectiveness, safety and acceptability. Mean in vitro drug release rates for the three doses were 150 and 15, 150 and 20 and 200 and 15 microg/day of NES and EE, respectively. Each ring remained in situ for 21 days, removed for 7 days and then reinserted for a total of 13 cycles of use. We studied ring performance with respect to pregnancy and other termination events, adverse events, the extent of ovulation inhibition, serum drug levels and bleeding control. We also assessed the rings' effects on the vagina using a standardized colposcopy procedure. Seventy-two percent of the women completed the 1-year (> or = 350 days) study. In studied cycles, luteal activity (progesterone > or = 10 nmol/L) was noted in 17%, 7% and 12% of subjects with monitored cycles at the 150/15, 150/20 and 200/15 doses, respectively (p = .34). Two pregnancies occurred, both in subjects using the 200/15 microg/day ring. Breakthrough bleeding during ring use averaged about 2 days/year and breakthrough bleeding and spotting averaged about 7 days/year. In the entire trial, only two women discontinued because of bleeding problems. Medical conditions, chiefly vaginal problems, personal reasons and device loss or repeated expulsion were the principal reasons given for study discontinuation. Vaginal and cervical colposcopy, conducted with standardized techniques and standardized interpretations, revealed no elevated event incidence attributable to ring use. Clinical performance and adverse event profiles indicate that each of these 1-year NES/EE rings, used on a 21-day-in and 7-day-out regimen, provided women effective, acceptable and safe long-acting contraception under their own control.

Adult↗

Clinical performance and menstrual bleeding patterns with three dosage combinations of a Nestorone progestogen/ethinyl estradiol contraceptive vaginal ring used on a bleeding-signaled regimen.

OBJECTIVE: We examined the clinical performance of contraceptive vaginal rings (rings) delivering Nestorone (NES) progestin and ethinyl estradiol (EE). Ring removal times were signaled by menstrual events. Bleeding patterns, adverse events, patterns of use and continuation rates were the principal parameters evaluated. METHODS: In a two-stage 6-month trial, subjects were randomized to use rings releasing 50 microg/day of NES and either 10 (50/10) or 20 (50/20) microg/day of EE. Subjects were to keep rings continuously in situ until menstrual bleeding or prolonged spotting-signaled removal. Reinsertion was to occur 96 h later. After the randomized stage, an open-label 6-month trial of rings releasing 150 microg/day of NES and 15 microg/day of EE (150/15) began with the same menstrually signaled regimen. RESULTS: Two-hundred forty-six subjects participated in the trial. Six-month pregnancy rates ranged by ring dose from 1.3 to 3.9 per 100. For each ring dose combination, 6-month continuation rates were above 80 per 100. Bleeding and spotting (B+S) days in women with the 50 microg/day NES rings were similar in number to those experienced by cycling women not using contraception. Nevertheless, in the initial 90 days, fewer B+S days were reported by subjects with the 50/20 ring than by subjects with the 50/10 ring (p < .05). Throughout the trial, subjects using the 150/15 ring reported significantly fewer B+S episodes than did subjects with either 50 microg/day NES ring. CONCLUSION: Combined contraceptive rings used with a bleeding-signaled regimen led to few terminations attributed to bleeding problems and to acceptable continuation rates. The 150/15 ring appeared to induce fewer bleeding problems than did the lower-dose NES combination rings, but no important difference in 6-month continuation rates among the three doses was noted.

Adult↗

Serum Nestorone and ethinyl estradiol levels, and ovulation inhibition in women using three different dosage combinations of a Nestorone progestogen-ethinyl estradiol contraceptive vaginal ring on a bleeding-signaled regimen.

OBJECTIVES: This trial tested the hypothesis that menstrually signaled use of contraceptive vaginal rings ("rings") releasing low-dose combinations of Nestorone (NES) and ethinyl estradiol (EE) would reliably suppress luteal activity and ovulation, and prevent unintended pregnancy, while controlling the incidence of menstrual bleeding episodes and bleeding days. METHODS: Nestorone/ethinyl estradiol rings releasing 50/10, 50/20 and 150/15 mug/day were studied through 6 months. A ring was to be used continuously, until its removal was signaled by menstrual bleeding. Reinsertion was required 96 h after removal. Serum for NES, EE and progesterone were collected and assayed, and vaginal ultrasound scans were performed in three 5-week periods to examine luteal activity, follicular growth, ovulation and their correlates. In 10 subjects using the 150/15 ring, six samples were drawn in the 24-h period after ring removal to examine serum levels of NES and EE. RESULTS: One hundred sixty subjects at three doses provided blood samples. Median serum concentrations of NES and EE demonstrated dose ratios slightly below the nominal dose ratios expected. Serum NES concentrations declined 19-22% from weeks 3 to 25. Changes in EE levels depended on dose. Nestorone levels fell 81% by 24 h after ring removal and EE levels fell by 50%. Luteal activity was completely suppressed in 94-95% of cycles and in 90% of subjects. Three pregnancies occurred in subjects participating in this serum sampling study. CONCLUSION: Satisfactory serum levels of NES and EE, and a high level of ovulation suppression were achieved. Irregular ring use, however, permitted pregnancies to occur.

Contraceptive Agents, Female↗

Two-year performance of a Nestorone-releasing contraceptive implant: a three-center study of 300 women.

A 2-year trial of a single Nestorone (NES) rod implant was conducted at three Latin American centers, each enrolling 100 women. We studied the safety, effectiveness and acceptability of this progestin-releasing contraceptive implant. Three pregnancies occurred, the last at 18 months of use. Because no pregnancies were expected in the first 18 months, the trial was halted. At that time, 224 women had completed at least 18 months of use, and 99 women had used the implant for more than 24 months. Few participants used adjunctive contraception between the time the study was halted and the time they had their implant removed. No additional pregnancies occurred before the removal of the last implant. The 2-year cumulative pregnancy rate was 1.7 per 100 with a Pearl index of 0.6 per 100 for the 2-year period. The 1-year and 2-year continuation rates were 80.5 and 66.7 per 100, respectively. Menstrual and medical disturbances were the principal reasons for discontinuation, followed by planned pregnancy. Headache and weight gain frequently led to discontinuation. The NES implant had little important effect on most clinical chemistry and lipid parameters. Over the study course, the mean change in hemoglobin was <1%. Slight modification of the design of this single 2-year implant, restoring features previously examined in clinical trials, is likely to improve its effectiveness. A single NES implant appears to provide acceptable contraception for women.

Adolescent↗

A clinical trial of 7 alpha-methyl-19-nortestosterone implants for possible use as a long-acting contraceptive for men.

Several preparations of testosterone and its esters are being investigated alone or in combination with other gonadotropin-suppressing agents as possible antifertility agents for men. We studied the effectiveness of 7 alpha-methyl-19-nortestosterone (MENT) as an antispermatogenic agent in men. MENT has been shown to be more potent than testosterone and to be resistant to 5 alpha-reduction. For sustained delivery of MENT, we used a system consisting of ethylene vinyl acetate implants containing MENT acetate (Ac), administered subdermally. Thirty-five normal volunteers were recruited in 3 clinics and were randomly assigned to 1 of 3 doses: 1 (12 men), 2 (11 men), or 4 (12 men) MENT Ac implants. The initial average in vitro release rate of MENT Ac from each implant was approximately 400 micro g/day. Implants were inserted subdermally in the medial aspect of the upper arm under local anesthesia. The duration of treatment was initially designed to be 6 months. However, in 2 clinics the duration of treatment was extended to 9 months for the 2-implant group and to 12 months for the 4-implant group. Dose-related increases in serum MENT levels and decreases in testosterone, LH, and FSH levels were observed. Effects on sperm counts were also dose related. None of the subjects in the 1-implant group exhibited oligozoospermia (sperm count, <3 million/ml). Four subjects in the 2-implant group became oligozoospermic, 2 of whom reached azoospermia. Eight subjects in the 4-implant group reached azoospermia, with 1 exhibiting oligozoospermia, whereas 2 were nonresponders. Side effects generally seen with androgen administration, such as increases in erythrocyte count, hematocrit, and hemoglobin and a decrease in SHBG, were also seen in this study and were reversible. Changes in lipid parameters were moderate and transient. Liver enzymes showed small changes. This study demonstrates that MENT Ac, when administered in a sustained release fashion via subdermal implants, can inhibit spermatogenesis over a prolonged period after a single administration and has the potential to be used as a male contraceptive.

Adult↗

Risks and benefits, advantages and disadvantages of levonorgestrel-releasing contraceptive implants.

Levonorgestrel-releasing implants are long acting contraceptives, approved for 5 years of continuous use. Two marketed systems, the six capsule Norplant use of tradenames is for product identification purposes only and does not imply endorsement. and the two rod Jadelle, have essentially equal rates of drug release, pregnancy and adverse events over 5 years of use. Randomised clinical trials and controlled cohort observations indicate that for the first 3 years, when pregnancy rates are at or almost zero, no other contraceptive system is more effective, although etonogestrel implants provide equal effectiveness. Annual pregnancy rates rise in the fifth year of continuous use but remain below 1 per 100 women. Annual pregnancy rates of Norplant users remain below 1 per 100 throughout 7 years of continuous use. Levonorgestrel implants provide low progestogen doses; 40-50 microg/day at 1 year of use, decreasing to 25-30 microg/day in the fifth year. Serum levels of levonorgestrel at 5 years are 60-65% of those levels measured at 1 month of use. Adverse effects with levonorgestrel implants are similar to those observed with progestogen only and combined oral contraceptives. Risks of ectopic pregnancy, other pregnancy complications and pelvic inflammatory disease are reduced in comparison with those of women using copper or non-medicated intrauterine devices. Risks of developing gallbladder disease and hypertension or borderline hypertension, although small, are about 1.5 and 1.8 times greater, respectively, in women using levonorgestrel implants than in women not using hormonal contraception. Other serious diseases have not been found to occur significantly more frequently in levonorgestrel implant users than in women not using hormonal contraception. The great majority of levonorgestrel implant users experience menstrual problems, but serious bleeding problems are not more frequent than in controls. Other health problems reported more frequently by levonogestrel implant users than by women not using hormonal contraception in a study of 16000 women included skin conditions, headache, upper limb neuropathies, dizziness, nervousness, malaise, minor visual disturbances, respiratory conditions, arthropathies, weight change, anxiety and non-clinical depression. Clinical depression is not more frequent in women using implants compared with those not using hormonal contraception (i.e. using intrauterine devices, sterilisation). Removal problems occur less frequently with Jadelle than with Norplant. The mean removal time for Jadelle is half that of Norplant. Levonorgestrel implants in nationally representative scientific samples, in randomised trials, and in controlled cohort studies have continuation rates as high as or higher than any other reversible contraceptive over a duration of 5 years. This would imply that the satisfaction women derive from the contraceptive effectiveness of levonorgestrel implants greatly outweighs the dissatisfaction that may accompany menstrual disturbances and other adverse effects associated with implants.

Contraceptive Agents, Female↗

Recent developments in contraceptive implants at the Population Council.

Development of contraceptive implant methods, when based on established or on new synthetic chemical entities, is a decadal or multi-decadal process. The process often requires the cooperation of numerous investigators for laboratory work, for early Phase II trials, for dose-finding trials, and for Phase III clinical trials. The Phase III work also requires cooperation with a commercial manufacturer and potential distributor of the product. The Population Council has recently completed developmental work on two levonorgestrel-releasing implants, with filings to regulatory agencies that support extended use of Jadelle implants for 5 years and Norplant implants for 7 years. When the developmental process includes establishing the clinical properties of a molecule not yet approved by regulatory agencies, the minimum development time appears to be two decades. The status and rationale of studies of a new Nestorone-releasing, single implant developed by the Population Council for a period of use of 2 years are presented.

Academies and Institutes↗