PubMed Health⌕ Search

Biomedical subjects

Itaru Takehara

Publications and source records attributed to Itaru Takehara.

3 recordsLinked to original sources

Pharynx and oesophagus evaluation during the swallow using helical computerized tomography.

PURPOSE: Videofluorography (VF) and endoscopy are commonly used for dynamic imaging (DI) of pharyngeal swallowing but do not offer transverse plane (TP) information. The aim of the present study was to evaluate helical computerized tomography (HCT) to measure the DI capability pharyngeal swallowing in the TP. METHODS: The HCT scan technique used was a single-slice cine mode with scan times of 100 ms. All 15 subjects were studied supine during dry swallow, swallowing of barium sulphate jelly and 3, 10, 15 or 20 ml of a 40% barium sulphate solution. Nine subjects repeated the test twice at more than 1 week's interval to determine the test-retest reliability. RESULTS: Swallowing leads to closure of the vocal folds, pharyngeal constriction and narrowing of the piriform sinuses allowing jelly passage between the sinuses. Laryngeal elevation then occurs with the opening of the pharyngoesophageal segment (PES). Swallowing a bolus of 20 ml produced the maximum anteroposterior and transverse diameters as well as the maximum opening area of the PES. The test-retest intraclass correlation coefficients with liquid deglutition ranged from 0.86 to 0.98. CONCLUSIONS: This study shows that HCT enables visualization of TP of PES complementing VF or endoscopic swallowing studies.

Adult↗

Reliability of quantitative motor unit action potential parameters.

We evaluated the test-retest reliability (reproducibility) of motor unit action potential (MUAP) parameters in multi-MUAP analysis over time. Reproducibility studies are not available for needle quantitative electromyography (QEMG) performed by the same examiner. Fourteen consecutive individuals (10 men and 4 women) had repeat QEMG at 3 hours after the first examination, and seven (5 men and 2 women) had a repeat QEMG after 4-10 days. The intraclass correlation coefficient (ICC) was 87-97% with same-day testing and 52-81% with different-day testing. Size index and firing rate were the most reproducible, suggesting use in follow-up multi-MUAP studies.

Action Potentials↗

Dynamic postural control in patients with hemiparesis.

OBJECTIVE: Decreased postural stability is a common problem associated with hemiparesis secondary to stroke. The purpose of this study was to evaluate dynamic postural control in patients with hemiparesis and in normal subjects matched for age. DESIGN: Quantitative posturography (EquiTest System) was performed to assess the response of subjects to sudden perturbations. A total of 59 patients with hemiparesis and 98 healthy volunteers were evaluated. All the patients were able to walk inside their house without lower limb orthoses. Both the patients and the healthy volunteers were subjected to forward and backward perturbations while standing on a movable force platform. Balance responses were analyzed in terms of weight symmetry, latency, amplitude (relative response strength), and strength symmetry. They were also subjected to toes-up and toes-down perturbations to evaluate their response to a disruptive balance force. RESULTS: The response latency to perturbations was longer and the response strength was weaker on the paretic side of patients with hemiparesis. The dynamic postural control was impaired in patients with hemiparesis as compared with healthy subjects. CONCLUSION: The results suggest that patients with hemiparesis tend to fall easily and that the risk of falls toward the paretic side is high.

Adaptation, Physiological↗